510(k) Report

510(k) · Cleared

Cleared

Spinemed S200B/S200C

K051013510(k) TraditionalCleared Apr 27, 20056-day reviewClass II21 CFR 890.5900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cert Health Sciences, LLC · ITH Equipment, Traction, Powered

Cleared on Apr 27, 2005 as substantially equivalent to K001712 (The Saunders Group, 2000) and 1 other predicate after a 6-day review. Its family tree reaches back 2 generations to 1985.

Decided
Apr 27, 2005
Review
6 days
Class
Class II
Product code
ITH
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K844385 (1985). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 1 other ancestorK844385 · Escotek Est Trac 401 · Nor-Am Patient Care Products, Inc. · 1985K023160 · DRX5000 · Axiom Usa., Inc. · 200219851990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor K023160 · DRX5000 · Axiom Usa., Inc. · 2002K844385 · Escotek Est Trac 401 · Nor-Am Patient Care Products, Inc. · 19850
  1. Root · 2 generations backK844385 Escotek Est Trac 401Nor-Am Patient Care Products, Inc. · 1985
  2. 1 generation backK023160 DRX5000Axiom Usa., Inc. · 2002
  3. This deviceK051013 Spinemed S200B/S200CCert Health Sciences, LLC · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K844385Escotek Est Trac 401Nor-Am Patient Care Products, Inc.1985—
−1K023160DRX5000Axiom Usa., Inc.2002—
0 (this device)K051013Spinemed S200B/S200CCert Health Sciences, LLC2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K051013, 1985–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITH device

  1. #1 K243775 True Non-Surgical Spinal Decompression System…score 10.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K0017123D Activetrac
Summary page 1
…PRODUCT NUMBER CODE 3D Activetrac The Saunders Class IW/ITH K001712 Group- DRX5000 AXIOM USA Inc Class Il/ITH K023160 The r…
The Saunders Group2000—
*K023160DRX5000
Summary page 1
…The Saunders Class IW/ITH K001712 Group- DRX5000 AXIOM USA Inc Class Il/ITH K023160 The rationale of declaring the SpineMED S200B/C is substantial equivalent to the above 2 predicate devices are based on the foll…
Axiom Usa., Inc.2002—

Also cleared against K001712: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 17.6 years on median.
  • None of the 3 ancestors has a recall.
  • 6 other devices also cite its predicate K001712.

How does its category compare?

All ITH devices

ITH Equipment, Traction, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · ITH

2in 2025

2007: 22008: 42009: 12010: 12011: 12012: 12014: 22015: 22023: 12024: 12025: 2
2007high 4 (2008) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITH

132in 2008

2008: 132 days median
2007high 132 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITH

2in 2011

2011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ITH

3in 2025

2007: 22009: 32010: 32011: 52012: 12013: 22014: 52015: 12016: 22017: 22019: 52021: 12023: 12024: 52025: 3
2007high 5 (2011) · low 0 (2008)2025

MAUDE reports naming product code ITH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—02
2008413200
20091—03
20101—03
20111—25
20121—01
20130—02
20142—05
20152—01
20160—02
20170—02
20180—00
20190—05
20200—00
20210—01
20220—00
20231—01
20241—05
20252—03
20260—0—

What is it indicated for?

The SpineMED® System provides a program of treatments for relief from pain for those patients suffering with low back pain, neck pain or sciatica. Each treatment session consists of a physician prescribed treatment period on the SpineMED™ and is designed to provide static, intermittent, and cycling distraction forces to relieve pressures on structures that may be causing low back pain, neck pain or sciatica. It relieves pain associated with herniated discs, bulging or protruding discs, degenerative disc disease, posterior facet syndrome, and sciatica. It achieves these effects through decompression of intervertebral discs, that is, unloading due to distraction and positioning.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K051013: Spinemed S200B/S200C.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051013

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026