510(k) · Cleared
ClearedArctec Semirigid Plating System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Altiva Corp. · MNH Orthosis, Spondylolisthesis Spinal Fixation
Cleared on Oct 7, 2005 as substantially equivalent to K930353 (Smith & Nephew, Inc., 1995) and 4 other predicates after a 165-day review. Its family tree reaches back 2 generations to 1996.
- Decided
- Oct 7, 2005
- Review
- 165 days
- Class
- Class II
- Product code
- MNH
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 2 generations to K955348 (1996). 7 ancestors in all, the oldest K930353 (1995). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K955348 | Titanium Moss Miami Spinal System | Depuy, Inc. | 1996 | — |
| −1 | K964024 | Depuy Motech Titanium Moss Miami Spinal System | Depuy, Inc. | 1997 | — |
| 0 (this device) | K051044 | Arctec Semirigid Plating System | Altiva Corp. | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
| 1998 | 1 | 0 |
| 2005 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K930353 | Simmons Plating System Bolt and ScrewSummary page 1…Pedicle screw spinal system 21 CFR 888.3070, Class II MNH, MNI VI. PREDICATE DEVICE INFORMATION: Simmons Stainless Steel Plating System (K930353) Ultium Plating System (K962784) HydraLok System (KO51216) Rogozinski Spinal System (K983899) Titaniu… | 1995 |
| * | K962784 | Ultium Spinal Plating SystemSummary page 1…21 CFR 888.3070, Class II MNH, MNI VI. PREDICATE DEVICE INFORMATION: Simmons Stainless Steel Plating System (K930353) Ultium Plating System (K962784) HydraLok System (KO51216) Rogozinski Spinal System (K983899) Titanium Moss Miami Spinal System (K964024)… | 1996 |
| * | K051216 | Hydralok System Cleared while this submission was under review | 2005 |
| * | K983899 | Thoracolumbar Spinal Rod System (Empower)Summary page 1…RMATION: Simmons Stainless Steel Plating System (K930353) Ultium Plating System (K962784) HydraLok System (KO51216) Rogozinski Spinal System (K983899) Titanium Moss Miami Spinal System (K964024) VII. DEVICE DESCRIPTION: The ArcTeCTM Semi-Rigid Plating System in… | 1998 |
| * | K964024 | Depuy Motech Titanium Moss Miami Spinal SystemSummary page 1…tem (K930353) Ultium Plating System (K962784) HydraLok System (KO51216) Rogozinski Spinal System (K983899) Titanium Moss Miami Spinal System (K964024) VII. DEVICE DESCRIPTION: The ArcTeCTM Semi-Rigid Plating System includes plates, bolts, washers and locking nuts in… | 1997 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 8.5 years on median.
- 1 of the 7 ancestors has a recall of any class.
How does its category compare?
All MNH devicesMNH Orthosis, Spondylolisthesis Spinal Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MNH
8in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · MNH
93in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNH
1in 2016
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNH
89in 2025
MAUDE reports naming product code MNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 123 | 0 | 18 |
| 2008 | 13 | 65 | 0 | 30 |
| 2009 | 13 | 151 | 7 | 45 |
| 2010 | 10 | 106 | 0 | 59 |
| 2011 | 17 | 171 | 0 | 107 |
| 2012 | 7 | 93 | 1 | 433 |
| 2013 | 10 | 124 | 1 | 464 |
| 2014 | 12 | 140 | 0 | 286 |
| 2015 | 10 | 99 | 0 | 152 |
| 2016 | 8 | 93 | 1 | 216 |
| 2017 | 0 | — | 0 | 174 |
| 2018 | 0 | — | 0 | 129 |
| 2019 | 0 | — | 0 | 403 |
| 2020 | 0 | — | 0 | 432 |
| 2021 | 0 | — | 0 | 531 |
| 2022 | 0 | — | 0 | 265 |
| 2023 | 0 | — | 0 | 121 |
| 2024 | 0 | — | 0 | 302 |
| 2025 | 0 | — | 0 | 89 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The ArcTecTM Semi-Rigid Plating System is intended for posterior, noncervical, pedicle fixation in order to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine, including degenerative spondylolisthesis with objective evidence of neurological impairment; fracture…
Read the full statement (133 words)
The ArcTecTM Semi-Rigid Plating System is intended for posterior, noncervical, pedicle fixation in order to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine, including degenerative spondylolisthesis with objective evidence of neurological impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis).
In addition, when used as a pedicle screw fixation system, the ArcTecTM Semi-Rigid Plating System is intended for skeletally mature patients with severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra, who are receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 and below), with removal of the implants after the attainment of solid fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051044 · printed Nov 4, 2026
Cite this page
510(k) Report. “K051044: Arctec Semirigid Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K051044