510(k) Report

510(k) · Cleared

Cleared

Raycell X-Ray Blood Irradiator

K051065510(k) SpecialCleared May 26, 200530-day reviewClass U

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mds Nordion · MOT Irradiator, Blood To Prevent Graft Versus Host Disease

Cleared on May 26, 2005 after a 30-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 4 later devices descend from it.

Decided
May 26, 2005
Review
30 days
Class
Class U
Product code
MOT
Recalls
None
Predicates
0

4 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2017: 1 descendant cleared2019: 1 descendant cleared2020: 1 descendant cleared20052010201520202025
  1. This deviceK051065 Raycell X-Ray Blood IrradiatorMds Nordion · 2005
  2. Descendant · cites it directly · 1 of its ownK172087 SangrayHitachi, Ltd. · 2017
  3. Descendant · cites it directly · 1 of its ownK161324 Raycell Mk2Best Theratronics Limited · 2016
  4. Descendant · 2 generations on · 0 of its ownK201177 RadGil2R3 X-Ray L.L.C · 2020
  5. Descendant · 2 generations on · 0 of its ownK181737 Raycell MK1Best Theratronics Limited · 2019

Most influential descendants

Showing 4 of 4 · See all
  • K172087SangrayHitachi, Ltd. · 2017 · cites it directly1descendant
  • K161324Raycell Mk2Best Theratronics Limited · 2016 · cites it directly1descendant
  • K201177RadGil2R3 X-Ray L.L.C · 2020 · 2 generations on0descendants
  • K181737Raycell MK1Best Theratronics Limited · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K051065Raycell X-Ray Blood IrradiatorMds Nordion2005—
+1K172087SangrayHitachi, Ltd.2017—
+1K161324Raycell Mk2Best Theratronics Limited2016—
+2K201177RadGil2R3 X-Ray L.L.C2020—
+2K181737Raycell MK1Best Theratronics Limited2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201710
201910
202010
FIG. 1 — Lineage of K051065, 2005–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOT device

  1. #1 K201177 RadGil2score 0.8 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172087SangrayHitachi, Ltd.20171
K161324Raycell Mk2Best Theratronics Limited20161

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K172087 (Hitachi, Ltd., 2017) has gone furthest, with 1 descendant of its own.

How does its category compare?

All MOT devices

MOT Irradiator, Blood To Prevent Graft Versus Host Disease: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MOT

1in 2020

2009: 12016: 12017: 12019: 12020: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOT

Too few MOT 510(k)s in any year since 2007 to give a median.

Recalls per year · MOT

No recall names MOT since 2007.

Adverse event reports per year · MOT

1in 2014

2009: 12010: 22014: 1
2007high 2 (2010) · low 0 (2007)2025

MAUDE reports naming product code MOT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20091—01
20100—02
20110—00
20120—00
20130—00
20140—01
20150—00
20161—00
20171—00
20180—00
20191—00
20201—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The RaycellTM X-ray Blood Irradiator is intended for use in the irradiation of blood and blood products (packaged in transfusion bags) to inactivate T-lymphocytes for the prevention of Graft Versus Host Disease according to applicable FDA, AABB, Health Canada, and European guidelines.

The Raycell'" X-ray Blood Irradiator is also intended for use in the irradiation of intra-operatively salvaged blood for cancer patients undergoing surgery to assist in the prevention of metastasis.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K051065: Raycell X-Ray Blood Irradiator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051065

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026