510(k) · Cleared
ClearedPrevail Dental Implants
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Implant Innovations, Inc. · DZE Implant, Endosseous, Root-Form
Cleared on Jun 8, 2005 as substantially equivalent to K031632 (Implant Innovations, Inc., 2003) and 2 other predicates after a 29-day review. Its family tree reaches back 6 generations to 1993. 317 later devices descend from it.
- Decided
- Jun 8, 2005
- Review
- 29 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 6 generations to K925765 (1993). 59 ancestors in all, the oldest K781060 (1978). 317 later devices descend from it, 5 citing it directly.
- Root · 6 generations backK925765 Branemark System Standard 3.75MM FixtureNobelpharma USA, Inc. · 1993
- 5 generations backK994376 Frialit-2 3.4MM Steeped Cylinder Implant with Frios TPS Coating…Friadent GmbH · 2000
- 4 generations backK014235 Osseotite NT Dental Implants & AccessoriesImplant Innovations, Inc. · 2002
- 3 generations backK022009 3I Implants; Osseotite Dental Implants; Osseotite NT Dental ImplantsImplant Innovations, Inc. · 2002
- 2 generations backK031475 Osseotite NT Certain ImplantsImplant Innovations, Inc. · 2003
- 1 generation backK041402 Modification to Osseotite NT Certain ImplantsImplant Innovations, Inc. · 2004
- This deviceK051189 Prevail Dental ImplantsImplant Innovations, Inc. · 2005
- Descendant · cites it directly · 312 of its ownK051461 3I Osseotite Dental ImplantsImplant Innovations, Inc. · 2005
- Descendant · 2 generations on · 211 of its ownK063286 Osseotite; Osseotite NT; XP; TG OsseotiteImplant Innovations, Inc. · 2007 · Recalled
- Descendant · cites it directly · 209 of its ownK063341 3I Osseotite Certain Dental ImplantsImplant Innovations, Inc. · 2007 · Recalled
- Descendant · 3 generations on · 196 of its ownK120414 Osseospeed PlusAstra Tech AB · 2012
- Descendant · 2 generations on · 86 of its ownK170588 DESS Dental Smart SolutionsTerrats Medical SL · 2017
Showing 5 of 317 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 317 · See all- K0514613I Osseotite Dental ImplantsImplant Innovations, Inc. · 2005 · cites it directly312descendants
- K063286Osseotite; Osseotite NT; XP; TG OsseotiteImplant Innovations, Inc. · 2007 · 2 generations on211descendants
- K0633413I Osseotite Certain Dental ImplantsImplant Innovations, Inc. · 2007 · cites it directly209descendants
- K120414Osseospeed PlusAstra Tech AB · 2012 · 3 generations on196descendants
- K170588DESS Dental Smart SolutionsTerrats Medical SL · 2017 · 2 generations on86descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K925765 | Branemark System Standard 3.75MM Fixture | Nobelpharma USA, Inc. | 1993 | — |
| −5 | K994376 | Frialit-2 3.4MM Steeped Cylinder Implant with Frios TPS Coating; Frialit-2… | Friadent GmbH | 2000 | — |
| −4 | K014235 | Osseotite NT Dental Implants & Accessories | Implant Innovations, Inc. | 2002 | — |
| −3 | K022009 | 3I Implants; Osseotite Dental Implants; Osseotite NT Dental Implants | Implant Innovations, Inc. | 2002 | — |
| −2 | K031475 | Osseotite NT Certain Implants | Implant Innovations, Inc. | 2003 | — |
| −1 | K041402 | Modification to Osseotite NT Certain Implants | Implant Innovations, Inc. | 2004 | — |
| 0 (this device) | K051189 | Prevail Dental Implants | Implant Innovations, Inc. | 2005 | — |
| +1 | K051461 | 3I Osseotite Dental Implants | Implant Innovations, Inc. | 2005 | — |
| +2 | K063286 | Osseotite; Osseotite NT; XP; TG Osseotite | Implant Innovations, Inc. | 2007 | 5 |
| +1 | K063341 | 3I Osseotite Certain Dental Implants | Implant Innovations, Inc. | 2007 | 10 |
| +3 | K120414 | Osseospeed Plus | Astra Tech AB | 2012 | — |
| +2 | K170588 | DESS Dental Smart Solutions | Terrats Medical SL | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1982 | 1 | 0 |
| 1985 | 1 | 0 |
| 1986 | 2 | 0 |
| 1987 | 2 | 0 |
| 1988 | 1 | 0 |
| 1989 | 5 | 0 |
| 1990 | 5 | 0 |
| 1992 | 2 | 0 |
| 1994 | 6 | 0 |
| 1995 | 4 | 0 |
| 1996 | 5 | 0 |
| 1997 | 4 | 0 |
| 1998 | 3 | 0 |
| 1999 | 3 | 0 |
| 2000 | 2 | 0 |
| 2001 | 2 | 0 |
| 2002 | 2 | 0 |
| 2003 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 1 | 0 |
| 2007 | 6 | 0 |
| 2008 | 6 | 0 |
| 2009 | 2 | 0 |
| 2010 | 1 | 0 |
| 2011 | 6 | 0 |
| 2012 | 4 | 0 |
| 2013 | 8 | 0 |
| 2014 | 11 | 0 |
| 2015 | 12 | 0 |
| 2016 | 14 | 0 |
| 2017 | 14 | 0 |
| 2018 | 13 | 0 |
| 2019 | 18 | 0 |
| 2020 | 19 | 0 |
| 2021 | 19 | 0 |
| 2022 | 31 | 0 |
| 2023 | 32 | 0 |
| 2024 | 40 | 0 |
| 2025 | 38 | 0 |
| 2026 | 22 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K031632 | Osseotite Iol Implants and Osseotite Certain Iol ImplantsSummary page 2…e subject of this 510(k) submission and are similar to the ones currently marketed and cleared in the following premarket notifications: * K031632 - OSSEOTITE IOL Implants, cleared by letter dated September 16, 2003. * K041402 - OSSEOTITE NTTM Ce… | 2003 |
| * | K041402 | Modification to Osseotite NT Certain ImplantsSummary page 2…following premarket notifications: * K031632 - OSSEOTITE IOL Implants, cleared by letter dated September 16, 2003. * K041402 - OSSEOTITE NTTM Certain 3.25mm Implants, cleared by letter dated June 16, 2004. * K935544 - 3i Imp… | 2004 |
| * | K935544 | 3I Standard Threaded/Self-Tapping Threaded Implants ModificationSummary page 2…tember 16, 2003. * K041402 - OSSEOTITE NTTM Certain 3.25mm Implants, cleared by letter dated June 16, 2004. * K935544 - 3i Implants, cleared by letter dated March 13, 1995.… | 1995 |
What descends from it? (317)
See all 3175 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 12 months on median.
- 8 of the 59 ancestors have a recall of any class.
- Of its descendants, K051461 (Implant Innovations, Inc., 2005) has gone furthest, with 312 descendants of its own.
- 6 other devices also cite its predicate K031632.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
3i dental implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restoration and in partially or fully edentulous spans with multiple single teeth, freestanding bridges and to retain overdentures.
In addition, when a minimum of 4 implants, > 10 mm in length, are placed in the mandible and splinted in the anterior region, immediate loading is indicated.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051189 · printed Nov 4, 2026
Cite this page
510(k) Report. “K051189: Prevail Dental Implants.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K051189
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026