510(k) · Cleared
ClearedEasy Core Detachable Biopsy System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Boston Scientific Corp · KNW Instrument, Biopsy
Cleared on Jun 16, 2005 after a 22-day review. The FDA summary names its predicate without a number.
- Decided
- Jun 16, 2005
- Review
- 22 days
- Class
- Class II
- Product code
- KNW
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KNW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KNW device
- #1 K260572 Marrow Marxmanscore 14.5 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Easy Core Biopsy System Named without a submission number | |
| * | — | Easy Core Biopsy System II Named without a submission number | |
| * | — | ASAP Biopsy System (Formerly referred to as Stamey Sampler Spring Loaded Needle) Named without a submission number | |
| * | — | ASAP 14g Biopsy System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KNW devicesKNW Instrument, Biopsy: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KNW
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KNW
178in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KNW
1in 2024
Class I (4 since 2007) Class II/III not classified
Adverse event reports per year · KNW
1,667in 2025
MAUDE reports naming product code KNW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 94 | 1 | 766 |
| 2008 | 4 | 53 | 7 | 363 |
| 2009 | 6 | 35 | 3 | 351 |
| 2010 | 3 | 57 | 2 | 162 |
| 2011 | 10 | 64 | 5 | 67 |
| 2012 | 7 | 94 | 1 | 93 |
| 2013 | 3 | 100 | 1 (1) | 98 |
| 2014 | 8 | 95 | 3 | 193 |
| 2015 | 10 | 106 | 0 | 591 |
| 2016 | 9 | 127 | 5 | 297 |
| 2017 | 8 | 90 | 1 | 760 |
| 2018 | 7 | 71 | 0 | 1,012 |
| 2019 | 5 | 94 | 4 | 4,195 |
| 2020 | 8 | 92 | 0 | 5,120 |
| 2021 | 9 | 54 | 3 | 1,020 |
| 2022 | 8 | 203 | 3 | 535 |
| 2023 | 7 | 164 | 2 | 931 |
| 2024 | 5 | 114 | 1 | 1,283 |
| 2025 | 12 | 178 | 0 | 1,667 |
| 2026 | 7 | 29 | 4 (3) | — |
What is it indicated for?
The Easy Core Detachable Biopsy System is indicated for use endoscopically or percutaneously to retrieve tissue sampling of soft organs/tumors or masses for histological analysis. Soft tissue sampling includes but is not limited to organs such as breast, liver, kidney and prostate.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051361 · printed Nov 6, 2026
Cite this page
510(k) Report. “K051361: Easy Core Detachable Biopsy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051361
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)