510(k) Report

510(k) · Cleared

Cleared

Datex-Ohmeda S/5 Device Interfacing Solution

K051634510(k) SpecialCleared Jul 19, 200529-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Healthcare · MSX System, Network And Communication, Physiological Monitors

Cleared on Jul 19, 2005 as substantially equivalent to K012531 (Datex-Ohmeda, 2001) after a 29-day review. Its family tree reaches back 2 generations to 1994. 1 later device descends from it.

Decided
Jul 19, 2005
Review
29 days
Class
Class II
Product code
MSX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K935477 (1994). 1 later device descends from it, 1 citing it directly.

  1. Root · 2 generations backK935477 AS/3(TM) Anesthesia Monitor Syst Interface BoardDatex Division Instrumentarium Corp. · 1994
  2. 1 generation backK012531 Datex-Ohmeda S/5 Device Interfacing Solution, N-DisxxxxDatex-Ohmeda · 2001
  3. This deviceK051634 Datex-Ohmeda S/5 Device Interfacing SolutionGE Healthcare · 2005
  4. Descendant · cites it directly · 0 of its ownK070421 Datex-Ohmeda S/5 Device Interfacing Solution, N-Disxxxx..01 with…GE Healthcare · 2007 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K070421Datex-Ohmeda S/5 Device Interfacing Solution, N-Disxxxx..01 with N-Disvent..02GE Healthcare · 2007 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K935477AS/3(TM) Anesthesia Monitor Syst Interface BoardDatex Division Instrumentarium Corp.1994—
−1K012531Datex-Ohmeda S/5 Device Interfacing Solution, N-DisxxxxDatex-Ohmeda2001—
0 (this device)K051634Datex-Ohmeda S/5 Device Interfacing SolutionGE Healthcare2005—
+1K070421Datex-Ohmeda S/5 Device Interfacing Solution, N-Disxxxx..01 with N-Disvent..02GE Healthcare20071

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
FIG. 1 — Lineage of K051634, 1994–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MSX device

  1. #1 K242750 Central Stationscore 21.5 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012531Datex-Ohmeda S/5 Device Interfacing Solution, N-Disxxxx
Summary page 1
…Sxxxx..0l is substantially equivalent in safety and effectiveness to the legally marketed (predicate) S/5 T MDevice Interfacing Solution, N- DISxxxx..00 (K01253 1). ko'i 6S4…
Datex-Ohmeda2001—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070421Datex-Ohmeda S/5 Device Interfacing Solution, N-Disxxxx..01 with N-Disvent..02GE Healthcare20070

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 7.3 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K070421 (GE Healthcare, 2007) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MSX devices

MSX System, Network And Communication, Physiological Monitors: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MSX

4in 2025

2007: 42008: 12009: 12010: 32011: 72012: 42013: 22014: 32015: 52016: 32017: 22018: 42019: 42020: 52021: 32022: 52023: 32024: 42025: 42026 (partial year): 5
2007high 7 (2011) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MSX

295in 2025

2007: 58 days median2010: 43 days median2011: 72 days median2012: 145 days median2014: 165 days median2015: 138 days median2016: 174 days median2018: 111 days median2019: 92 days median2020: 193 days median2021: 227 days median2022: 177 days median2023: 244 days median2024: 212 days median2025: 295 days median2026 (partial year): 145 days median
2007high 295 (2025) · low 43 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MSX

1in 2025

2007: 12008: 12009: 22010: 12011: 12012: 22015: 22017: 22018: 12022: 12025: 12026 (partial year): 2
2007high 2 (2009) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MSX

19in 2025

2007: 52008: 62009: 72010: 142011: 32012: 42013: 172014: 322015: 312016: 112017: 162018: 152019: 152020: 252021: 172022: 182023: 102024: 322025: 19
2007high 32 (2014) · low 3 (2011)2025

MAUDE reports naming product code MSX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200745815
20081—16
20091—27
2010343114
201177213
2012414524
20132—017
20143165032
20155138231
20163174011
20172—216
20184111115
2019492015
20205193025
20213227017
20225177118
20233244010
20244212032
20254295119
202651452—

What is it indicated for?

The Datex-Ohmeda S/5 Device Interfacing Solution, N-DISxxxx..01, is indicated for data transfer between stand-alone monitors, ventilators/anesthesia machines, blood gas analyzers, and heart-lung machines and Datex-Ohmeda bedside monitors for displaying and patient care information purposes. The device is indicated for use by qualified medical personnel only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K051634: Datex-Ohmeda S/5 Device Interfacing Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K051634

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026