510(k) Report

510(k) · Cleared

Cleared

Accent and Exceed Series Orthodontic Ceramic Brackets

K052245510(k) TraditionalCleared Sep 23, 200537-day reviewClass II21 CFR 872.5470

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lar Mfg., LLC · NJM Bracket, Ceramic, Orthodontic

Cleared on Sep 23, 2005 as substantially equivalent to K042178 (Dentsply Intl., 2004) after a 37-day review. Its family tree reaches back 2 generations to 1985.

Decided
Sep 23, 2005
Review
37 days
Class
Class II
Product code
NJM
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K852179 (1985). No later device cites it as a predicate yet.

  1. Root · 2 generations backK852179 Ceramic Orthodonit ApplianceGac Intl., Inc. · 1985
  2. 1 generation backK042178 Orthodontic Ceramic BracketsDentsply Intl. · 2004
  3. This deviceK052245 Accent and Exceed Series Orthodontic Ceramic BracketsLar Mfg., LLC · 2005
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K852179Ceramic Orthodonit ApplianceGac Intl., Inc.1985—
−1K042178Orthodontic Ceramic BracketsDentsply Intl.2004—
0 (this device)K052245Accent and Exceed Series Orthodontic Ceramic BracketsLar Mfg., LLC2005—
FIG. 1 — Lineage of K052245, 1985–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NJM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NJM device

  1. #1 K222764 LightForce Orthodontic Systemscore 8.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042178Orthodontic Ceramic Brackets
Summary page 2
…mary of Safety and Effectiveness LAR Manufacturing, LLC Orthodontic Ceramic Brackets Predicate Device(s) 510(kW Device Manufacturer K042178 Mystic Orthodontic Dentsply International Ceramic Brackets Device Description LAR Man…
Dentsply Intl.2004—

Also cleared against K042178: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 19.0 years on median.
  • None of the 2 ancestors has a recall.
  • 3 other devices also cite its predicate K042178.

How does its category compare?

All NJM devices

NJM Bracket, Ceramic, Orthodontic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NJM

5in 2023

2007: 12008: 42009: 42010: 12011: 42012: 62013: 32014: 12015: 32016: 32017: 32018: 42019: 62020: 22021: 12022: 22023: 5
2007high 6 (2012) · low 0 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NJM

1in 2023

2008: 134 days median2009: 61 days median2011: 122 days median2012: 90 days median2013: 123 days median2015: 234 days median2016: 176 days median2017: 183 days median2018: 76 days median2019: 200 days median2023: 1 days median
2007high 234 (2015) · low 1 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NJM

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NJM

1in 2025

2009: 12010: 22011: 12012: 12013: 62016: 22017: 22018: 22020: 12023: 12024: 22025: 1
2007high 6 (2013) · low 0 (2007)2025

MAUDE reports naming product code NJM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
2008413400
200946101
20101—02
2011412201
201269001
2013312316
20141—00
2015323400
2016317602
2017318302
201847602
2019620000
20202—01
20211—00
20222—00
20235101
20240—02
20250—01
20260—0—

What is it indicated for?

The LAR Manufacturing, LLC Orthodontic Ceramic Brackets are indicated for orthodontic movement of teeth.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052245: Accent and Exceed Series Orthodontic Ceramic Brackets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052245

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026