Impedimed - Body Composition Analyzer, Model Imp SFB7

K052319510(k) TraditionalCleared Apr 4, 2006222-day reviewClass II21 CFR 870.2770

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Impedimed Pty, Ltd. · MNW Analyzer, Body Composition

Cleared on Apr 4, 2006 as substantially equivalent to K904109 (Xitron Technologies, Inc., 1991) after a 222-day review. Its family tree reaches back 1 generation to 1991. 13 later devices descend from it.

Decided
Apr 4, 2006
Review
222 days
Class
Class II
Product code
MNW
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K904109 (1991). 13 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared2019: 1 descendant cleared2015: 1 descendant cleared2011: 1 descendant cleared2023: 2 descendants cleared2013: 1 descendant cleared2022: 1 descendant cleared2017: 2 descendants cleared2018: 2 descendants cleared2026: 1 descendant clearedK904109 · Bio-Impedance Analyzer · Xitron Technologies, Inc. · 19911990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 2 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants6 generations forward: 2 descendants K904109 · Bio-Impedance Analyzer · Xitron Technologies, Inc. · 19910+5
  1. Root · 1 generation backK904109 Bio-Impedance AnalyzerXitron Technologies, Inc. · 1991
  2. This deviceK052319 Impedimed - Body Composition Analyzer, Model Imp SFB7Impedimed Pty, Ltd. · 2006
  3. Descendant · cites it directly · 10 of its ownK080825 Impedimed Extra Cellular Fluid Analysis, Model L-Dex U400Impedimed Pty, Ltd. · 2008
  4. Descendant · 2 generations on · 7 of its ownK100811 Impedimed - Extracellular Fluid Analyzer Model: L-Dex U400ImpediMed Limited · 2011
  5. Descendant · 3 generations on · 6 of its ownK130338 Impedimed - Bis Extra Cellular Fluid AnalysisImpediMed Limited · 2013
  6. Descendant · 4 generations on · 2 of its ownK171186 Cerebrotech CMS-5000Cerebrotech Medical Systems · 2017
  7. Descendant · 4 generations on · 2 of its ownK172122 SOZOImpediMed Limited · 2017

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2008: 12011: 12013: 12015: 12017: 22018: 22019: 12022: 12023: 22026: 1
2008high 2 (2017) · low 0 (2009)2026

Most influential descendants

Showing 5 of 13 · See all
  • K080825Impedimed Extra Cellular Fluid Analysis, Model L-Dex U400Impedimed Pty, Ltd. · 2008 · cites it directly10descendants
  • K100811Impedimed - Extracellular Fluid Analyzer Model: L-Dex U400ImpediMed Limited · 2011 · 2 generations on7descendants
  • K130338Impedimed - Bis Extra Cellular Fluid AnalysisImpediMed Limited · 2013 · 3 generations on6descendants
  • K171186Cerebrotech CMS-5000Cerebrotech Medical Systems · 2017 · 4 generations on2descendants
  • K172122SOZOImpediMed Limited · 2017 · 4 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K904109Bio-Impedance AnalyzerXitron Technologies, Inc.1991—
0 (this device)K052319Impedimed - Body Composition Analyzer, Model Imp SFB7Impedimed Pty, Ltd.2006—
+1K080825Impedimed Extra Cellular Fluid Analysis, Model L-Dex U400Impedimed Pty, Ltd.2008—
+2K100811Impedimed - Extracellular Fluid Analyzer Model: L-Dex U400ImpediMed Limited2011—
+3K130338Impedimed - Bis Extra Cellular Fluid AnalysisImpediMed Limited2013—
+4K171186Cerebrotech CMS-5000Cerebrotech Medical Systems2017—
+4K172122SOZOImpediMed Limited2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
201110
201310
201510
201720
201820
201910
202210
202320
202610
FIG. 1 — Lineage of K052319, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MNW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MNW device

  1. #1 K231116 Multi-parameter detectorscore 11.4 · 14 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K904109Bio-Impedance Analyzer
Summary page 2
…Xitron Technologies, Inc Device name: Bio-Impedlance Analyzer 510 (K) number: K 904109 Product code: DSB Classification panel: Cardiovascular Device cl…
Xitron Technologies, Inc.1991—

Also cleared against K904109: 2 other devices →

What descends from it? (13)

See all 13

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080825Impedimed Extra Cellular Fluid Analysis, Model L-Dex U400Impedimed Pty, Ltd.200810
K190529SOZOImpediMed Limited20191

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K080825 (Impedimed Pty, Ltd., 2008) has gone furthest, with 10 descendants of its own.
  • 2 other devices also cite its predicate K904109.

How does its category compare?

All MNW devices

MNW Analyzer, Body Composition: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MNW

1in 2024

2007: 42008: 42009: 42010: 12011: 112012: 42013: 92014: 32015: 12024: 1
2007high 11 (2011) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNW

110in 2014

2007: 109 days median2008: 134 days median2009: 137 days median2011: 168 days median2012: 103 days median2013: 144 days median2014: 110 days median
2007high 168 (2011) · low 103 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MNW

No recall names MNW since 2007.

Adverse event reports per year · MNW

3in 2024

2010: 12015: 22016: 152017: 62018: 162019: 112020: 122021: 102022: 82023: 22024: 3
2007high 16 (2018) · low 0 (2007)2025

MAUDE reports naming product code MNW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007410900
2008413400
2009413700
20101—01
20111116800
2012410300
2013914400
2014311000
20151—02
20160—015
20170—06
20180—016
20190—011
20200—012
20210—010
20220—08
20230—02
20241—03
20250—00
20260—0—

What is it indicated for?

(1) Imp SFB7 - A bioelectrical impedance analyzer/monitor that is intended to estimate the following body composition parameters: Fat-free Mass (FFM), Fat Mass (FM), Total Body Water (TBW), Intra cellular Fluid (ICF), Extra cellular Fluid (ECF), and Body Mass Index (BMI). The device measures current, voltage and phase angle (Phi), and from these values calculates resistance (R), reactance (Xc), and impedance (Z), which are used to estimate the above body…

Read the full statement (255 words)

(1) Imp SFB7 - A bioelectrical impedance analyzer/monitor that is intended to estimate the following body composition parameters: Fat-free Mass (FFM), Fat Mass (FM), Total Body Water (TBW), Intra cellular Fluid (ICF), Extra cellular Fluid (ECF), and Body Mass Index (BMI). The device measures current, voltage and phase angle (Phi), and from these values calculates resistance (R), reactance (Xc), and impedance (Z), which are used to estimate the above body composition parameters. The device/software will also display the Cole-Cole plot, resistance vs. frequency plot, reactance vs. frequency plot, subject height, weight, age and sex.

(2) BioImp Body Composition Analyzer PC Software: A PC software package that is intended to be used only with the ImpediMed Imp SFB7 Analyzer for uploading the MFBIA mode data on to the PC from Imp SFB7 via an Ethernet port for storing, processing and analysing of MFBIA bioimpedance measurements. This displays Cole-Cole plot, body composition parameters: Fat-free Mass (FFM), Fat Mass (FM), Total Body Water (TBW), Intra cellular Fluid (ICF), Extra cellular Fluid (ECF), Body Mass Index (BMI), and subject height, weight, age, sex, time, and date of measurement, Practitioner's name and Device serial number, and bioelectrical parameters resistance (R), reactance (Xc), and impedance (Z) and phase angle (Phi) at different frequencies (Between 4 kHz to 1000 kHz). The software can be used to generate patient body composition report displaying all the parameters stated above.

These devices are intended to be used only on healthy patients, who wish to have their body composition estimated in the home or clinical environment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052319: Impedimed - Body Composition Analyzer, Model Imp SFB7.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052319

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026