510(k) Report

510(k) · Cleared

Cleared

I-PORT

K052389510(k) AbbreviatedCleared Sep 9, 20059-day reviewClass II21 CFR 880.5200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Patton Medical Devices · FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

Cleared on Sep 9, 2005 as substantially equivalent to K881767 (Ohmeda Medical, 1988) and 1 other predicate after a 9-day review. Its family tree reaches back 1 generation to 1988. 1 later device descends from it.

Decided
Sep 9, 2005
Review
9 days
Class
Class II
Product code
FOZ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K881767 (1988). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor2012: 1 descendant clearedK881767 · Viggo Insuflon · Ohmeda Medical · 19881990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K881767 · Viggo Insuflon · Ohmeda Medical · 19880
  1. Root · 1 generation backK881767 Viggo InsuflonOhmeda Medical · 1988
  2. This deviceK052389 I-PORTPatton Medical Devices · 2005
  3. Descendant · cites it directly · 0 of its ownK120337 I-Port Advance Injection PortUnomedical A/S · 2012

Most influential descendants

Showing 1 of 1 · See all
  • K120337I-Port Advance Injection PortUnomedical A/S · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K881767Viggo InsuflonOhmeda Medical1988—
0 (this device)K052389I-PORTPatton Medical Devices2005—
+1K120337I-Port Advance Injection PortUnomedical A/S2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
FIG. 1 — Lineage of K052389, 1988–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FOZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FOZ device

  1. #1 K243403 BD Nexiva™ Closed IV Catheter Systemscore 14.8 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K881767Viggo Insuflon
Summary page 1
…Device Classification: Class II Product Code: FOZ 3.3 Predicate Devices * Unomedical, Inc. Insuflon TM, Intravascular Catheter (K881767) · Medtronic MiniMed Paradigm® Sof-set® Infusion Sets (K030149) 3.4 Device Description The I-PORTTM, Injection Port is…
Ohmeda Medical1988—
*K030149Medtronic Minimed Sof-Site Infusion Set, Models MMT-359S6, MMT-359M6, MMT-359L6…
Summary page 1
…FOZ 3.3 Predicate Devices * Unomedical, Inc. Insuflon TM, Intravascular Catheter (K881767) · Medtronic MiniMed Paradigm® Sof-set® Infusion Sets (K030149) 3.4 Device Description The I-PORTTM, Injection Port is a sterile, single use, low profile injection port through which physic…
Avail Medical Products, Inc.20031

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K120337I-Port Advance Injection PortUnomedical A/S20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K120337 (Unomedical A/S, 2012) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FOZ devices

FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FOZ

11in 2025

2007: 62008: 92009: 92010: 32011: 62012: 132013: 42014: 92015: 102016: 92017: 92018: 12019: 82020: 102021: 42022: 82023: 92024: 62025: 112026 (partial year): 7
2007high 13 (2012) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FOZ

91in 2025

2007: 159 days median2008: 103 days median2009: 30 days median2010: 28 days median2011: 132 days median2012: 122 days median2013: 104 days median2014: 99 days median2015: 107 days median2016: 63 days median2017: 51 days median2019: 140 days median2020: 191 days median2021: 242 days median2022: 183 days median2023: 129 days median2024: 190 days median2025: 91 days median2026 (partial year): 203 days median
2007high 242 (2021) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FOZ

4in 2023

2007: 162009: 232010: 1152013: 22014: 42016: 3, 1 Class I2017: 222018: 42019: 32020: 32021: 12022: 4, 2 Class I2023: 4, 2 Class I2026 (partial year): 2
2007high 115 (2010) · low 0 (2008)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · FOZ

5,110in 2025

2007: 3742008: 4222009: 5082010: 3702011: 7862012: 5602013: 6402014: 8152015: 7292016: 9252017: 1,9662018: 3,3052019: 4,3652020: 3,7972021: 4,6742022: 4,1332023: 4,4302024: 4,7722025: 5,110
2007high 5,110 (2025) · low 370 (2010)2025

MAUDE reports naming product code FOZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007615916374
200891030422
200993023508
2010328115370
201161320786
2012131220560
201341042640
20149994815
2015101070729
20169633 (1)925
2017951221,966
20181—43,305
2019814034,365
20201019133,797
2021424214,674
202281834 (2)4,133
202391294 (2)4,430
2024619004,772
2025119105,110
202672032—

What is it indicated for?

The I-PORTTM, Injection Port is indicated for patients who administer, or to whom is administered, multiple daily subcutaneous injections of physician prescribed medications, including insulin. The I-PORT TM, Injection Port may remain in place for up to 72 hours to accommodate multiple drug injections without the discomfort of additional needle sticks.

This device may be used on a wide range of patients, including adults and children.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052389: I-PORT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K052389

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026