510(k) · Cleared
Recalled · 2006Rubicor Encapsule Breast Biopsy Device, Model 31108
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Rubicor Medical, Inc. · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Oct 6, 2005 as substantially equivalent to K023601 (Rubicor Medical, Inc., 2002) and 1 other predicate after a 23-day review. Its family tree reaches back 4 generations to 1993. 1 later device descends from it. It has been recalled once.
- Decided
- Oct 6, 2005
- Review
- 23 days
- Class
- Class II
- Product code
- GEI
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 4 generations to K922123 (1993). 6 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 4 generations backK922123 Auto Suture Disposable Endoscopic Specimen PouchUnited States Surgical, A Division of Tyco Healthc · 1993
- 3 generations backK020047 Rubicor Breast Biopsy DeviceRubicor Medical, Inc. · 2002 · Recalled
- 2 generations backK023601 Rubicor Encapsule Breast Biopsy Device, Model 30086Rubicor Medical, Inc. · 2002 · Recalled
- 1 generation backK030049 Modification to Rubicor Encapsule Breast Biopsy Device, Model 30086Rubicor Medical, Inc. · 2003 · Recalled
- This deviceK052506 Rubicor Encapsule Breast Biopsy Device, Model 31108Rubicor Medical, Inc. · 2005
- Descendant · cites it directly · 0 of its ownK070275 Flexible Loop Electrosurgical ElectrodeRubicor Medical, Inc. · 2007
Most influential descendants
Showing 1 of 1 · See all- K070275Flexible Loop Electrosurgical ElectrodeRubicor Medical, Inc. · 2007 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K922123 | Auto Suture Disposable Endoscopic Specimen Pouch | United States Surgical, A Division of Tyco Healthc | 1993 | — |
| −3 | K020047 | Rubicor Breast Biopsy Device | Rubicor Medical, Inc. | 2002 | 1 |
| −2 | K023601 | Rubicor Encapsule Breast Biopsy Device, Model 30086 | Rubicor Medical, Inc. | 2002 | 1 |
| −1 | K030049 | Modification to Rubicor Encapsule Breast Biopsy Device, Model 30086 | Rubicor Medical, Inc. | 2003 | 1 |
| 0 (this device) | K052506 | Rubicor Encapsule Breast Biopsy Device, Model 31108 | Rubicor Medical, Inc. | 2005 | — |
| +1 | K070275 | Flexible Loop Electrosurgical Electrode | Rubicor Medical, Inc. | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2007 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023601 | Rubicor Encapsule Breast Biopsy Device, Model 30086Summary page 1…valent Device: The subject device and accessory are substantially equivalent in intended use and/or method of operation to the Rubicor EnCapsule TM Breast Biopsy Device (K023601 & K030049) Intended Use: The EnCapsule Breast Biopsy Device is intended for diagnostic sampling of breast tissue during breast b… | 2002 |
| * | K030049 | Modification to Rubicor Encapsule Breast Biopsy Device, Model 30086Summary page 1…ice: The subject device and accessory are substantially equivalent in intended use and/or method of operation to the Rubicor EnCapsule TM Breast Biopsy Device (K023601 & K030049) Intended Use: The EnCapsule Breast Biopsy Device is intended for diagnostic sampling of breast tissue during breast biopsy proc… | 2003 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K070275 | Flexible Loop Electrosurgical Electrode | 2007 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Feb 17, 2006 | Not classified | Z-0715-06 | Other | Devices' sterility may be compromised due to lack of adequate sterilization. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 12 years and passes through 2 companies; a new generation was cleared every 2.7 years on median.
- 4 of the 6 ancestors have a recall of any class.
- Of its descendants, K070275 (Rubicor Medical, Inc., 2007) has gone furthest, with 0 descendants of its own.
- 2 other devices also cite its predicate K023601.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
The EnCapsule Breast Biopsy Device is intended for diagnostic sampling of breast tissue during breast biopsy procedures. It is to be used for diagnostic purposes only and is not intended for therapeutic uses. The EnCapsule Breast Biopsy Device is indicated to provide breast tissue samples for diagnostic sampling of breast abnormalities. It is designed to provide breast tissue for histologic examination with partial or complete removal of the imaged…
Read the full statement (133 words)
The EnCapsule Breast Biopsy Device is intended for diagnostic sampling of breast tissue during breast biopsy procedures. It is to be used for diagnostic purposes only and is not intended for therapeutic uses.
The EnCapsule Breast Biopsy Device is indicated to provide breast tissue samples for diagnostic sampling of breast abnormalities. It is designed to provide breast tissue for histologic examination with partial or complete removal of the imaged abnormality. The extent of histologic abnormality cannot be reliably determined from its mammographic appearance. Therefore, the extent of removal of the imaged evidence of an abnormality does not predict the extent of removal of a histologic abnormality (e.g., malignancy). When the sampled abnormality is not histologically benign, it is essential that the tissue margins be examined for completeness of removal using standard surgical procedures.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K052506 · printed Nov 6, 2026
Cite this page
510(k) Report. “K052506: Rubicor Encapsule Breast Biopsy Device, Model 31108.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052506
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026