510(k) · Cleared
ClearedSuretek Medical Reprocessed Compression Sleeves
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Suretek Medical · JOW Sleeve, Limb, Compressible
Cleared on May 17, 2006 as substantially equivalent to K022786 (Huntleigh Healthcare, Inc., 2002) and 11 other predicates after a 231-day review. Its family tree reaches back 3 generations to 1988.
- Decided
- May 17, 2006
- Review
- 231 days
- Class
- Class II
- Product code
- JOW
- Recalls
- None
- Predicates
- 12
Its longest line of descent runs back 3 generations to K881632 (1988). 28 ancestors in all, the oldest K781357 (1978). No later device cites it as a predicate yet.
- Root · 3 generations backK881632 Flowtron DVT System AC500 Pump, L501 GarmentHuntleigh Technology, Inc. · 1988
- 2 generations backK974318 Healthcare Service and Supply Alp Alternating Leg Pressure Pump and…Healthcare Service and Supply · 1998
- 1 generation backK012403 Vanguard Reprocessed Compression GarmentVanguard Medical Concepts, Inc. · 2001 · Recalled
- This deviceK052691 Suretek Medical Reprocessed Compression SleevesSuretek Medical · 2006
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K881632 | Flowtron DVT System AC500 Pump, L501 Garment | Huntleigh Technology, Inc. | 1988 | — |
| −2 | K974318 | Healthcare Service and Supply Alp Alternating Leg Pressure Pump and Gaarments… | Healthcare Service and Supply | 1998 | — |
| −1 | K012403 | Vanguard Reprocessed Compression Garment | Vanguard Medical Concepts, Inc. | 2001 | 6 |
| 0 (this device) | K052691 | Suretek Medical Reprocessed Compression Sleeves | Suretek Medical | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1986 | 1 | 0 |
| 1989 | 1 | 0 |
| 1991 | 1 | 0 |
| 1993 | 3 | 0 |
| 1995 | 3 | 0 |
| 1996 | 4 | 0 |
| 1997 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 2 | 0 |
| 2001 | 1 | 0 |
| 2002 | 3 | 0 |
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JOW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JOW device
- #1 K253555 Flexitouch® Plus Advanced Pneumatic…score 14.8 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (12)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K022786 | DVT60Summary page 1…turer/Reprocessor Tradename(s) 510(k)'s Devices Huntleigh Healthcare Flowtron* K022786, K010744 Kendall (Tyco Healthcare) SCD*, Impad* K992079, K964425… | 2002 |
| * | K010744 | Flowtron Universal, Model AC600Summary page 1…rocessor Tradename(s) 510(k)'s Devices Huntleigh Healthcare Flowtron* K022786, K010744 Kendall (Tyco Healthcare) SCD*, Impad* K992079, K964425… | 2002 |
| * | K992079 | Kendall Model 7325 SCD Response Compression System, Model 7325Summary page 1…hcare Flowtron* K022786, K010744 Kendall (Tyco Healthcare) SCD*, Impad* K992079, K964425 Kinetic Concepts Plexipulse* K981311… | 1999 |
| * | K964425 | A-V Impulse System Model 6060Summary page 1…Flowtron* K022786, K010744 Kendall (Tyco Healthcare) SCD*, Impad* K992079, K964425 Kinetic Concepts Plexipulse* K981311 Comp… | 1997 |
| * | K981311 | Cowboy XVSummary page 1…ealthcare) SCD*, Impad* K992079, K964425 Kinetic Concepts Plexipulse* K981311 Compression Therapy VasoPress* K003828 Curr… | 1999 |
| * | K003828 | Vaso Press DVT Foot Garment #VP 520Summary page 1…c Concepts Plexipulse* K981311 Compression Therapy VasoPress* K003828 Currie Medical Alternating Leg Pressure, ALP* K000303 Airc… | 2001 |
| * | K000303 | Healthcare Service and Supply Alp Alternating Leg Pressure Pump and Garments for the LimbSummary page 1…ssion Therapy VasoPress* K003828 Currie Medical Alternating Leg Pressure, ALP* K000303 Aircast Venaflow* K992454, K023800… | 2000 |
| * | K992454 | Venaflow System, Model 30ASummary page 1…Medical Alternating Leg Pressure, ALP* K000303 Aircast Venaflow* K992454, K023800 Alba Health pulStar* K961405… | 2000 |
| * | K023800 | Venaflow Reusable Calf Aircell, Model 3018, Venaflow Disposable Calf Cover, Model 3017Summary page 1…Alternating Leg Pressure, ALP* K000303 Aircast Venaflow* K992454, K023800 Alba Health pulStar* K961405 Ster… | 2003 |
| * | K961405 | Alba Health Pas Wrap SystemSummary page 1…Venaflow* K992454, K023800 Alba Health pulStar* K961405 SterilMed Reprocessed Compression Sleeves K012597 Vang… | 1996 |
| * | K012597 | Sterilmed Reprocessed Compression SleevesSummary page 1…ealth pulStar* K961405 SterilMed Reprocessed Compression Sleeves K012597 Vanguard Medical Concepts Reprocessed Compression Garment K012403 Device Comp… | 2002 |
| * | K012403 | Vanguard Reprocessed Compression GarmentSummary page 1…Med Reprocessed Compression Sleeves K012597 Vanguard Medical Concepts Reprocessed Compression Garment K012403 Device Compression Sleeves are inflatable cuffs designed to apply intermittent pressure to the foot, calf Design a… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 4 companies; a new generation was cleared every 4.6 years on median.
- 6 of the 28 ancestors have a recall of any class.
- 1 other device also cites its predicate K022786.
How does its category compare?
All JOW devicesJOW Sleeve, Limb, Compressible: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JOW
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JOW
168in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JOW
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JOW
24in 2025
MAUDE reports naming product code JOW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 66 | 0 | 12 |
| 2008 | 4 | 112 | 7 | 36 |
| 2009 | 3 | 84 | 0 | 45 |
| 2010 | 18 | 71 | 2 | 66 |
| 2011 | 11 | 104 | 3 | 50 |
| 2012 | 13 | 63 | 2 | 100 |
| 2013 | 17 | 94 | 0 | 169 |
| 2014 | 16 | 91 | 0 | 93 |
| 2015 | 10 | 160 | 0 | 137 |
| 2016 | 9 | 121 | 0 | 150 |
| 2017 | 9 | 116 | 1 | 149 |
| 2018 | 11 | 136 | 0 | 114 |
| 2019 | 11 | 88 | 1 | 102 |
| 2020 | 14 | 158 | 0 | 50 |
| 2021 | 16 | 132 | 0 | 34 |
| 2022 | 7 | 80 | 0 | 27 |
| 2023 | 6 | 160 | 0 | 57 |
| 2024 | 8 | 197 | 0 | 30 |
| 2025 | 7 | 168 | 0 | 24 |
| 2026 | 6 | 252 | 0 | — |
What is it indicated for?
SureTek Compression Sleeves are intended for use with a compatible pump controller for intermittent compression of the lower extremities so as to increase venous return as a prophylaxis to Deep Vein Thrombosis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K052691 · printed Nov 5, 2026
Cite this page
510(k) Report. “K052691: Suretek Medical Reprocessed Compression Sleeves.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K052691
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026