510(k) · Cleared

Recalled · 2007

Allocraft DBM

K052735510(k) TraditionalCleared Dec 28, 200589-day reviewClass II21 CFR 888.3045Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Lifecell Corp. · MBP Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)

Cleared on Dec 28, 2005 after an 89-day review. The FDA summary names its predicate without a number. It has been recalled 2 times.

Decided
Dec 28, 2005
Review
89 days
Class
Class II
Product code
MBP
Recalls
2
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K052735Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MBP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MBP device

  1. #1 K242799 PliaFX Floscore 9.0 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Musculoskeletal Transplant Foundation's DBX® Demineralized Bone Matrix
Named without a submission number
—
*—Wright Medical's AlloMatrix®
Named without a submission number
—
*—Exactech's Resorbable Bone Paste
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 17, 2007Not classifiedZ-1299-2008Release of Material/Component prior to receiving test resultsImproper donor screening test; diagnostic test kits were used in lieu of a donor screening test kits for HBsAG and HBcAB (later re-testing with FDA-approved donor screening test found samples non-reactive for both Hepatitis B Surface…
Oct 17, 2007Not classifiedZ-1298-2008Release of Material/Component prior to receiving test resultsImproper donor screening test; diagnostic test kits were used in lieu of a donor screening test kits for HBsAG and HBcAB (later re-testing with FDA-approved donor screening test found samples non-reactive for both Hepatitis B Surface…

No ancestor or descendant has a Class I recall.

How does its category compare?

All MBP devices

MBP Filler, Bone Void, Osteoinduction (W/O Human Growth Factor): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MBP

1in 2024

2007: 52008: 52009: 12011: 12012: 12013: 32015: 12024: 1
2007high 5 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MBP

181in 2013

2007: 188 days median2008: 93 days median2013: 181 days median
2007high 188 (2007) · low 93 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MBP

7in 2023

2011: 22012: 132014: 12016: 12023: 72026 (partial year): 2
2007high 13 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MBP

2in 2025

2007: 72008: 152009: 92010: 142011: 182012: 242013: 162014: 152015: 112016: 62017: 52018: 92019: 32020: 62021: 22022: 42023: 62024: 12025: 2
2007high 24 (2012) · low 1 (2024)2025

MAUDE reports naming product code MBP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007518807
2008593015
20091—09
20100—014
20111—218
20121—1324
20133181016
20140—115
20151—011
20160—16
20170—05
20180—09
20190—03
20200—06
20210—02
20220—04
20230—76
20241—01
20250—02
20260—2—

What is it indicated for?

AlloCraft is intended for use as bone void filler for voids or gaps that are not intrinsic to the stability of the bony structure. AlloCraft can be used to fill bone voids in the posterolateral spine. It is indicated for use in the treatment of surgically created osseous defects or osseous defects created from traumatic injury.

AlloCraft is intended for single patient use only

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K052735: Allocraft DBM.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052735

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026