510(k) · Cleared
ClearedImplantmed SI-915 (115V Version); Implantmed SI-923 (230V Version) Incl. Accessories
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
W&H Dentalwerk Buermoos GmbH · EBW Controller, Foot, Handpiece And Cord
Cleared on Jan 13, 2006 as substantially equivalent to K002469 (W&H Dentalwerk Buermoos GmbH, 2001) after a 105-day review. Its family tree reaches back 1 generation to 2001. 27 later devices descend from it.
- Decided
- Jan 13, 2006
- Review
- 105 days
- Class
- Class I
- Product code
- EBW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K002469 (2001). 27 later devices descend from it, 8 citing it directly.
- Root · 1 generation backK002469 Implantmed SI-95 115 (100-130 V) and SI-95 230 (220-240 V)W&H Dentalwerk Buermoos GmbH · 2001
- This deviceK052741 Implantmed SI-915 (115V Version); Implantmed SI-923 (230V Version)…W&H Dentalwerk Buermoos GmbH · 2006
- Descendant · cites it directly · 8 of its ownK161957 W&H Implantmed SI-1015 incl. AccessoriesW&H Dentalwerk Burmoos GmbH · 2016
- Descendant · 2 generations on · 5 of its ownK173905 Surgic Pro, Surgic Pro+Nakanishi, Inc. · 2018
- Descendant · cites it directly · 4 of its ownK123695 Traus SIP10Saeshin Precision Co., Ltd. · 2012
- Descendant · cites it directly · 4 of its ownK092214 Chiropro L SystemBien-Air Dental, SA · 2009 · Recalled
- Descendant · cites it directly · 3 of its ownK080939 Surgical Handpieces, Mikro Saw HandpiecesW&H Dentalwerk Buermoos GmbH · 2008 · Recalled
Showing 5 of 27 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 27 · See all- K161957W&H Implantmed SI-1015 incl. AccessoriesW&H Dentalwerk Burmoos GmbH · 2016 · cites it directly8descendants
- K173905Surgic Pro, Surgic Pro+Nakanishi, Inc. · 2018 · 2 generations on5descendants
- K123695Traus SIP10Saeshin Precision Co., Ltd. · 2012 · cites it directly4descendants
- K092214Chiropro L SystemBien-Air Dental, SA · 2009 · cites it directly4descendants
- K080939Surgical Handpieces, Mikro Saw HandpiecesW&H Dentalwerk Buermoos GmbH · 2008 · cites it directly3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K002469 | Implantmed SI-95 115 (100-130 V) and SI-95 230 (220-240 V) | W&H Dentalwerk Buermoos GmbH | 2001 | — |
| 0 (this device) | K052741 | Implantmed SI-915 (115V Version); Implantmed SI-923 (230V Version) Incl.… | W&H Dentalwerk Buermoos GmbH | 2006 | — |
| +1 | K161957 | W&H Implantmed SI-1015 incl. Accessories | W&H Dentalwerk Burmoos GmbH | 2016 | — |
| +2 | K173905 | Surgic Pro, Surgic Pro+ | Nakanishi, Inc. | 2018 | — |
| +1 | K123695 | Traus SIP10 | Saeshin Precision Co., Ltd. | 2012 | — |
| +1 | K092214 | Chiropro L System | Bien-Air Dental, SA | 2009 | 1 |
| +1 | K080939 | Surgical Handpieces, Mikro Saw Handpieces | W&H Dentalwerk Buermoos GmbH | 2008 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 1 | 0 |
| 2011 | 2 | 0 |
| 2012 | 2 | 0 |
| 2014 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2017 | 2 | 0 |
| 2018 | 1 | 0 |
| 2020 | 2 | 0 |
| 2021 | 4 | 0 |
| 2022 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new EBW device
- #1 K251701 Star E900 Electric Systemscore 12.2 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K002469 | Implantmed SI-95 115 (100-130 V) and SI-95 230 (220-240 V)Summary page 1…and maxillo surgery Classification Name: Controller, foot, handpiece and cord Predicate device: implantMED (K002469) Device ecipin The implantMVED S1-915/923 consist of a small hand held motor, a foot control and a controller. Accessories… | 2001 |
What descends from it? (27)
See all 278 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K161957 | W&H Implantmed SI-1015 incl. Accessories | 2016 | 8 |
| K123695 | Traus SIP10 | 2012 | 4 |
| K092214 | Chiropro L System | 2009 | 4 |
| K080939 | Surgical Handpieces, Mikro Saw Handpieces | 2008 | 3 |
| K100600 | Prosthodontic Screwdriver , Model IA-400 | 2010 | 2 |
| K092758 | X-CUBE | 2009 | 1 |
| K102241 | Anthogyr Implanteo Implantology and Dental Surgical Motor Unit | 2011 | 0 |
| K060287 | Drilltech, Ism, Implantunit, Zimmer Surgical Motor System | 2006 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All EBW devicesEBW Controller, Foot, Handpiece And Cord: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EBW
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · EBW
220in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · EBW
1in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EBW
13in 2025
MAUDE reports naming product code EBW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 5 | 112 | 0 | 16 |
| 2010 | 1 | — | 0 | 18 |
| 2011 | 3 | 226 | 0 | 1 |
| 2012 | 1 | — | 0 | 5 |
| 2013 | 1 | — | 1 | 1 |
| 2014 | 3 | 189 | 0 | 4 |
| 2015 | 1 | — | 0 | 13 |
| 2016 | 1 | — | 0 | 6 |
| 2017 | 4 | 227 | 0 | 13 |
| 2018 | 1 | — | 0 | 46 |
| 2019 | 2 | — | 0 | 55 |
| 2020 | 1 | — | 0 | 71 |
| 2021 | 2 | — | 0 | 57 |
| 2022 | 6 | 479 | 0 | 31 |
| 2023 | 0 | — | 0 | 17 |
| 2024 | 4 | 268 | 0 | 14 |
| 2025 | 3 | 220 | 0 | 13 |
| 2026 | 3 | 269 | 0 | — |
What is it indicated for?
Mechanical drive unit with coolant supply for transmission instruments with coupling system according to ISO 3964. The equipment is a drive unit for use in dental surgery, implantology, maxillo-facial surgery and endodontics for treatment of dental hard tissue and mechanical rotating root canal preparation
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K052741 · printed Nov 5, 2026
Cite this page
510(k) Report. “K052741: Implantmed SI-915 (115V Version); Implantmed SI-923 (230V Version) Incl. Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K052741
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026