Randox Calibration Serum

K053153510(k) TraditionalCleared Jan 13, 200664-day reviewClass II21 CFR 862.1150Recalls 6

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Randox Laboratories, Ltd. · JIX Calibrator, Multi-Analyte Mixture

Cleared on Jan 13, 2006 after a 64-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled 6 times.

Decided
Jan 13, 2006
Review
64 days
Class
Class II
Product code
JIX
Recalls
6
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared20052010201520202025
  1. This deviceK053153 Randox Calibration SerumRandox Laboratories, Ltd. · 2006
  2. Descendant · cites it directly · 0 of its ownK142181 Randox Aldolase Calibration SerumRandox Laboratories Limited · 2014

Most influential descendants

Showing 1 of 1 · See all
  • K142181Randox Aldolase Calibration SerumRandox Laboratories Limited · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K053153Randox Calibration SerumRandox Laboratories, Ltd.2006—
+1K142181Randox Aldolase Calibration SerumRandox Laboratories Limited2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
FIG. 1 — Lineage of K053153, 2006–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JIX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142181Randox Aldolase Calibration SerumRandox Laboratories Limited20140

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 5, 2024Class IIZ-1759-2024Process designRandox Laboratories has identified that Inorganic Phosphate in Calibration Serum Level 3, CAL2351 & CAL10388, is running with a negative bias on RX Series instruments compared to other methods.
Nov 20, 2023Class IIZ-0752-2024Under Investigation by firmCK Total in Calibration Serum Level 3, CAL2351, is running with a positive bias on RX Series instruments compared to other methods experience a shift in Quality Control and patient sample recovery of up to 13%.
Nov 20, 2023Class IIZ-0753-2024Under Investigation by firmTarget for Alkaline Phosphatase (ALP) for the AMP optimized to IFCC 37C method has been mis-assigned for the RX Series instruments by approximately 10% on Quality Control and patient samples
Nov 13, 2023Class IIZ-0751-2024Under Investigation by firmThere have been transcription errors on the Instructions For Use (IFU) of the Calibration Serum Level 3 (CAL2351 lot 1260UE, 1262UE and 1315UE) for target values of Bilirubin and Triglycerides, on the IFU of Human Assayed Multi-Sera Level…
Mar 29, 2021Class IIZ-1563-2021Nonconforming Material/ComponentRandox can confirm a positive bias for Total Bilirubin and Direct Bilirubin of up to +15% across the assay ranges when using calibrator CAL2351, lot 1162UE. The positive bias has been attributed to bilirubin instability in the calibrator…
Jul 12, 2019Class IIIZ-2490-2019Under Investigation by firmRandox Laboratories realigned RX Analyser Series calibration targets by 10% for AST and 9% for ALT in line with the Mean of All Instrument method target for the Randox Calibration Serum Level 3 (for calibrator lot 961UE onwards).

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K142181 (Randox Laboratories Limited, 2014) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JIX devices

JIX Calibrator, Multi-Analyte Mixture: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JIX

1in 2016

2007: 62008: 52009: 42010: 52011: 72012: 22013: 42014: 12015: 32016: 1
2007high 7 (2011) · low 0 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JIX

29in 2015

2007: 53 days median2008: 69 days median2009: 121 days median2010: 100 days median2011: 77 days median2013: 50 days median2015: 29 days median
2007high 121 (2009) · low 29 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JIX

7in 2023

2007: 22008: 32009: 22010: 12011: 22012: 12014: 12016: 12017: 12018: 12019: 12020: 22023: 72026 (partial year): 1
2007high 7 (2023) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JIX

18in 2025

2007: 1402008: 1732009: 392011: 92012: 32013: 242014: 352015: 42016: 62017: 172018: 162019: 122020: 222021: 92022: 112023: 132024: 152025: 18
2007high 173 (2008) · low 0 (2010)2025

MAUDE reports naming product code JIX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076532140
20085693173
20094121239
2010510010
201177729
20122—13
2013450024
20141—135
201532904
20161—16
20170—117
20180—116
20190—112
20200—222
20210—09
20220—011
20230—713
20240—015
20250—018
20260—1—

What is it indicated for?

This is an in vitro diagnostic product intended for use as a calibration serum in clinical chemistry assays. Randox calibration serum contains 43 analytes and is based on lyophilized human serum. The concentrations and activities are suitable for calibration of clinical chemistry assays both manually and on a wide range of automatic analysers. Constituent concentrations are available at 2 levels.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K053153: Randox Calibration Serum.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K053153

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026