510(k) Report

510(k) · Cleared

Recalled · 2006

Devilbiss Oxygen Cylinder Filling System, 535 Series

K053240510(k) TraditionalCleared Feb 3, 200677-day reviewClass II21 CFR 868.5440Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sunrise Medical · CAW Generator, Oxygen, Portable

Cleared on Feb 3, 2006 as substantially equivalent to K013472 (Chad Therapeutics, Inc., 2001) and 1 other predicate after a 77-day review. Its family tree reaches back 2 generations to 1997. 2 later devices descend from it. It has been recalled once.

Decided
Feb 3, 2006
Review
77 days
Class
Class II
Product code
CAW
Recalls
1
Predicates
2

Its longest line of descent runs back 2 generations to K971889 (1997). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2014: 1 descendant clearedK971889 · Chad Total O2 Delivery System · Chad Therapeutics, Inc. · 1997K013472 · Total O2 · Chad Therapeutics, Inc. · 20011995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K013472 · Total O2 · Chad Therapeutics, Inc. · 2001K971889 · Chad Total O2 Delivery System · Chad Therapeutics, Inc. · 19970
  1. Root · 2 generations backK971889 Chad Total O2 Delivery SystemChad Therapeutics, Inc. · 1997
  2. 1 generation backK013472 Total O2Chad Therapeutics, Inc. · 2001
  3. This deviceK053240 Devilbiss Oxygen Cylinder Filling System, 535 SeriesSunrise Medical · 2006
  4. Descendant · cites it directly · 1 of its ownK091191 Gas TransfillRespironics Inc., Sleep & Home Respiratory Group · 2009
  5. Descendant · 2 generations on · 0 of its ownK141967 Purefill Oxygen CompressorInovo, Inc. · 2014 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K091191Gas TransfillRespironics Inc., Sleep & Home Respiratory Group · 2009 · cites it directly1descendant
  • K141967Purefill Oxygen CompressorInovo, Inc. · 2014 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K971889Chad Total O2 Delivery SystemChad Therapeutics, Inc.1997—
−1K013472Total O2Chad Therapeutics, Inc.2001—
0 (this device)K053240Devilbiss Oxygen Cylinder Filling System, 535 SeriesSunrise Medical2006—
+1K091191Gas TransfillRespironics Inc., Sleep & Home Respiratory Group2009—
+2K141967Purefill Oxygen CompressorInovo, Inc.20141

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201410
FIG. 1 — Lineage of K053240, 1997–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAW device

  1. #1 K230052 Inogen Rove 6score 29.9 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013472Total O2
Summary page 1
…21 CFR 868.5440 Predicate Device Name(s) and 510(k) CHAD Therapeutics Total 02 number(s): Delivery System (K013472) CHAD Therapeutics Total 02…
Chad Therapeutics, Inc.2001—
*K971889Chad Total O2 Delivery System
Summary page 1
…y System (K013472) CHAD Therapeutics Total 02 Delivery System (K971889) DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service A…
Chad Therapeutics, Inc.1997—

Also cleared against K013472: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091191Gas TransfillRespironics Inc., Sleep & Home Respiratory Group20091

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 24, 2006Not classifiedZ-0038-2007OtherPotential for oxygen cylinders to not fill completely

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 4.2 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K091191 (Respironics Inc., Sleep & Home Respiratory Group, 2009) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K013472.

How does its category compare?

All CAW devices

CAW Generator, Oxygen, Portable: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CAW

12in 2025

2007: 62008: 112009: 82010: 52011: 62012: 52013: 22014: 62015: 12016: 12017: 12018: 32019: 22020: 52021: 22022: 42023: 82024: 22025: 122026 (partial year): 6
2007high 12 (2025) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAW

178in 2025

2007: 143 days median2008: 90 days median2009: 193 days median2010: 133 days median2011: 174 days median2012: 148 days median2014: 277 days median2018: 203 days median2020: 224 days median2022: 458 days median2023: 261 days median2025: 178 days median2026 (partial year): 260 days median
2007high 458 (2022) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAW

1in 2025

2007: 12008: 32009: 22011: 12013: 22014: 22016: 12017: 12019: 22020: 12022: 22024: 5, 1 Class I2025: 1
2007high 5 (2024) · low 0 (2010)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · CAW

611in 2025

2007: 232008: 252009: 432010: 482011: 1672012: 3952013: 2,3092014: 24,5382015: 18,9732016: 3,1672017: 1072018: 1162019: 1202020: 1252021: 1942022: 3052023: 3572024: 4502025: 611
2007high 24,538 (2014) · low 23 (2007)2025

MAUDE reports naming product code CAW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076143123
20081190325
20098193243
20105133048
201161741167
201251480395
20132—22,309
20146277224,538
20151—018,973
20161—13,167
20171—1107
201832030116
20192—2120
202052241125
20212—0194
202244582305
202382610357
20242—5 (1)450
2025121781611
202662600—

What is it indicated for?

The Model 535D Oxygen Cylinder Filling System is intended for use in supplying pressurized oxygen to fill oxygen cylinders for patients' ambulatory use. The device is intended to provide 93% (± 3%) oxygen. This device can be used in homes, nursing homes, patient care facilities, etc.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K053240: Devilbiss Oxygen Cylinder Filling System, 535 Series.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K053240

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026