510(k) · Cleared
ClearedM-Cor Hip Replacement System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Portland Orthopaedics Pty., Ltd. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Cleared on Jul 20, 2006 after a 224-day review. The FDA summary names its predicate without a number.
- Decided
- Jul 20, 2006
- Review
- 224 days
- Class
- Class II
- Product code
- LPH
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LPH device
- #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | S-ROM Femoral Hip Stem Named without a submission number | |
| * | — | Apex Modular Hip Named without a submission number | |
| * | — | Margron Hip Replacement Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LPH devicesLPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LPH
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LPH
153in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LPH
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LPH
6,163in 2025
MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 116 | 16 | 509 |
| 2008 | 10 | 86 | 1 | 706 |
| 2009 | 3 | 112 | 2 | 1,156 |
| 2010 | 15 | 100 | 22 | 2,007 |
| 2011 | 16 | 110 | 26 | 3,320 |
| 2012 | 25 | 76 | 30 | 3,785 |
| 2013 | 11 | 135 | 9 | 5,002 |
| 2014 | 20 | 129 | 3 | 5,163 |
| 2015 | 18 | 111 | 1 | 5,830 |
| 2016 | 10 | 150 | 8 | 4,900 |
| 2017 | 12 | 121 | 14 | 5,312 |
| 2018 | 9 | 145 | 2 | 5,954 |
| 2019 | 22 | 164 | 8 | 7,130 |
| 2020 | 7 | 164 | 6 | 5,429 |
| 2021 | 8 | 410 | 4 | 5,978 |
| 2022 | 14 | 247 | 2 | 5,223 |
| 2023 | 10 | 111 | 2 | 5,345 |
| 2024 | 6 | 92 | 1 | 5,626 |
| 2025 | 12 | 153 | 4 | 6,163 |
| 2026 | 8 | 256 | 2 | — |
What is it indicated for?
The M-COR Modular Hip System has the following indications for use: · The patient should be skeletally mature. * The patient's condition should be due to one or more of the following: I. Osteoarthritis. 2. Rheumatoid arthritis. 3. Ankylosing spondylitis 4. Psoriatic arthritis. 5. Tumor conditions involving the upper third of the femur or of the Acetabulum 6. Old osteomyelitis - with a long infection-free period and a nornal WBC, ESR and C-reactive…
Read the full statement (150 words)
The M-COR Modular Hip System has the following indications for use:
· The patient should be skeletally mature.
* The patient's condition should be due to one or more of the following:
I. Osteoarthritis.
2. Rheumatoid arthritis.
3. Ankylosing spondylitis
4. Psoriatic arthritis.
5. Tumor conditions involving the upper third of the femur or of the Acetabulum
6. Old osteomyelitis - with a long infection-free period and a nornal WBC, ESR and C-reactive protein.
7. Non-union of femoral neck fracture or avascular necrosis of the femoral head.
8. Post-traumatic fracture/dislocation of the hip.
9. Revision of an unsuccessful arthrodesis with either poor positioning or pain in the hip, or where low back pain or knee pain is becoming disabling.
10. Revision of an unsuccessful cemented or un-cemented hip replacement, providing sufficient bone stock is present.
11. Revision of a previous unsuccessful femoral osteotomy, Girdlestone resection, cup arthroplasty or hemi arthroplasty.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K053417 · printed Nov 6, 2026
Cite this page
510(k) Report. “K053417: M-Cor Hip Replacement System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K053417
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)