510(k) Report

510(k) · Cleared

Cleared

Smartpill GI Monitoring System

K053547510(k) TraditionalCleared Jul 18, 2006210-day reviewClass II21 CFR 876.1725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

The Smartpill Corporation · NYV Gastrointestinal Motility System, Capsule

Cleared on Jul 18, 2006 after a 210-day review. The FDA summary names its predicate without a number.

Decided
Jul 18, 2006
Review
210 days
Class
Class II
Product code
NYV
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K053547Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NYV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NYV device

  1. #1 K250940 Atmo Gas Capsule Systemscore 12.6 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Heidelberg pH Capsule
Named without a submission number
—
*—Heidelberg Gold Medallion Gastro-intestinal pH Measurement System
Named without a submission number
—
*—Unisensor UniTip Gastrointestinal Pressure Catheter
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All NYV devices

NYV Gastrointestinal Motility System, Capsule: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NYV

2in 2025

2009: 12025: 22026 (partial year): 1
2007high 2 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NYV

Too few NYV 510(k)s in any year since 2007 to give a median.

Recalls per year · NYV

No recall names NYV since 2007.

Adverse event reports per year · NYV

1in 2025

2008: 12009: 12010: 12011: 22012: 12015: 22016: 22017: 22019: 22020: 12021: 12022: 32023: 12024: 92025: 1
2007high 9 (2024) · low 0 (2007)2025

MAUDE reports naming product code NYV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20091—01
20100—01
20110—02
20120—01
20130—00
20140—00
20150—02
20160—02
20170—02
20180—00
20190—02
20200—01
20210—01
20220—03
20230—01
20240—09
20252—01
20261—0—

What is it indicated for?

The SmartPill GI Monitoring System is indicated for use in evaluating patients with suspected delayed gastric emptying (gastroparesis).

The SmartPill GI Monitoring System measures pH, pressure and temperature throughout the gastrointestinal tract. These physiological measurements are used to determine gastric emptying time (GET), total transit time (TTT), and combined small-large bowel transit time (SLBTT). In addition, pressure contraction patterns from the antrum and duodenum are used to calculate motility indices.

Delayed gastric emptying is implicated in such disorders as idiopathic and diabetic gastroparesis and functional non-ulcer dyspepsia.

Not for use in pediatric populations

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K053547: Smartpill GI Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K053547

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026