Nodecrest Transcranical Doppler Ultrasound System

K060112510(k) TraditionalCleared May 5, 2006108-day reviewClass II21 CFR 892.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nodecrest, LLC · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on May 5, 2006 as substantially equivalent to K974588 (Rimed, Ltd., 1998) after a 108-day review. Its family tree reaches back 1 generation to 1998. 8 later devices descend from it.

Decided
May 5, 2006
Review
108 days
Class
Class II
Product code
IYN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K974588 (1998). 8 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2010: 1 descendant cleared2013: 1 descendant cleared2026: 1 descendant cleared2018: 2 descendants cleared2019: 1 descendant cleared2022: 2 descendants clearedK974588 · Intra-View Bilateral Transcranial Doppler Device, Smart-Lite Portable Bilateral Transcranial Doppler Device, Compact Mod · Rimed, Ltd. · 19981995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 2 descendants4 generations forward: 3 descendants K974588 · Intra-View Bilateral Transcranial Doppler Device, Smart-Lite Portable Bilateral Transcranial Doppler Device, Compact Mod · Rimed, Ltd. · 19980
  1. Root · 1 generation backK974588 Intra-View Bilateral Transcranial Doppler Device, Smart-Lite…Rimed, Ltd. · 1998
  2. This deviceK060112 Nodecrest Transcranical Doppler Ultrasound SystemNodecrest, LLC · 2006
  3. Descendant · cites it directly · 7 of its ownK092164 Transcranial and Vascular Doppler Diagnotic Ultrasound Transducers…Shenzhen Delicate Electronics Co., Ltd. · 2010
  4. Descendant · 2 generations on · 5 of its ownK122710 Transcranial Doppler with Robotic Probe HeadbandShenzhen Delicate Electronics Co., Ltd. · 2013
  5. Descendant · 3 generations on · 2 of its ownK173801 Transcranial Doppler Ultrasound SystemShenzhen Delica Medical Equipment Co., Ltd. · 2018
  6. Descendant · 3 generations on · 1 of its ownK180455 NeuralBotNeural Analytics, Inc. · 2018 · Recalled
  7. Descendant · 2 generations on · 0 of its ownK254143 EM-TECH Passive Ultrasound Probe StrapEM-TECH Solutions, Inc. · 2026

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2010: 12013: 12018: 22019: 12022: 22026: 1
2010high 2 (2018) · low 0 (2011)2026

Most influential descendants

Showing 5 of 8 · See all
  • K092164Transcranial and Vascular Doppler Diagnotic Ultrasound Transducers, Model Ems-9UAShenzhen Delicate Electronics Co., Ltd. · 2010 · cites it directly7descendants
  • K122710Transcranial Doppler with Robotic Probe HeadbandShenzhen Delicate Electronics Co., Ltd. · 2013 · 2 generations on5descendants
  • K173801Transcranial Doppler Ultrasound SystemShenzhen Delica Medical Equipment Co., Ltd. · 2018 · 3 generations on2descendants
  • K180455NeuralBotNeural Analytics, Inc. · 2018 · 3 generations on1descendant
  • K254143EM-TECH Passive Ultrasound Probe StrapEM-TECH Solutions, Inc. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K974588Intra-View Bilateral Transcranial Doppler Device, Smart-Lite Portable…Rimed, Ltd.1998—
0 (this device)K060112Nodecrest Transcranical Doppler Ultrasound SystemNodecrest, LLC2006—
+1K092164Transcranial and Vascular Doppler Diagnotic Ultrasound Transducers, Model…Shenzhen Delicate Electronics Co., Ltd.2010—
+2K122710Transcranial Doppler with Robotic Probe HeadbandShenzhen Delicate Electronics Co., Ltd.2013—
+3K173801Transcranial Doppler Ultrasound SystemShenzhen Delica Medical Equipment Co., Ltd.2018—
+3K180455NeuralBotNeural Analytics, Inc.20181
+2K254143EM-TECH Passive Ultrasound Probe StrapEM-TECH Solutions, Inc.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201310
201820
201910
202220
202610
FIG. 1 — Lineage of K060112, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K974588Intra-View Bilateral Transcranial Doppler Device, Smart-Lite Portable Bilateral…
Summary page 2
…Nodecrest Rimed Ltd. 510(k) Number K974588 Transducer Frequency 2MHz, 4MHz, 8MHz 2MHz, 4MHz, 8MHz Frequency Spec…
Rimed, Ltd.1998—

Also cleared against K974588: 3 other devices →

What descends from it? (8)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092164Transcranial and Vascular Doppler Diagnotic Ultrasound Transducers, Model Ems-9UAShenzhen Delicate Electronics Co., Ltd.20107

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K092164 (Shenzhen Delicate Electronics Co., Ltd., 2010) has gone furthest, with 7 descendants of its own.
  • 3 other devices also cite its predicate K974588.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The range of Nodecrest Transcranial Doppler Ultrasound System is intended for use as a diagnostic ultrasound fluid flow analysis system: 1) For the measurement of cerebral artery blood velocities to determine the presence of hemodynamically significant deviations from normal values 2) To assess arterial cerebral blood flow for the occurrence of micro embolic signals. Vessels intended for observation include, but are not limited to the middle, anterior…

Read the full statement (146 words)

The range of Nodecrest Transcranial Doppler Ultrasound System is intended for use as a

diagnostic ultrasound fluid flow analysis system:

1) For the measurement of cerebral artery blood velocities to determine the

presence of hemodynamically significant deviations from normal values

2) To assess arterial cerebral blood flow for the occurrence of micro embolic

signals. Vessels intended for observation include, but are not limited to the

middle, anterior and posterior cerebral arteries, via the temporal windows, the

vertebral mid basilar arteries via the foramen magnum and the ophthalmic artery

and intracranial internal carotid artery via the eye.

The Nodecrest Transcranial Doppler is intended for use during:

a) Diagnostic exams

b) Surgical interventions

The device is not intended to replace other means of evaluating vital patient physiological

processes, is not intended to be used in fetal applications, and is not intended to be used

inside the sterile field.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K060112: Nodecrest Transcranical Doppler Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K060112

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026