K060307510(k) TraditionalCleared Aug 4, 2006178-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Medical Systems Information Technologies · DRT Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm)

Cleared on Aug 4, 2006 as substantially equivalent to K992595 (Hewlett-Packard GmbH, 1999) and 2 other predicates after a 178-day review. Its family tree reaches back 5 generations to 1995. 5 later devices descend from it.

Decided
Aug 4, 2006
Review
178 days
Class
Class II
Product code
DRT
Recalls
None
Predicates
3

Its longest line of descent runs back 5 generations to K946306 (1995). 33 ancestors in all, the oldest K872781 (1987). 5 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1999: 3 other ancestors1997: 3 other ancestors2002: 3 other ancestors1998: 4 other ancestors1994: 1 other ancestor1993: 2 other ancestors2000: 2 other ancestors1995: 2 other ancestors1992: 1 other ancestor1987: 1 other ancestor1996: 1 other ancestor1991: 2 other ancestors1990: 3 other ancestors2010: 1 descendant cleared2016: 2 descendants cleared2015: 2 descendants clearedK946306 · Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring System · Siemens Medical Solutions USA, Inc. · 1995×2: 2 generations cleared close together, K982730 (1998), K983632 (1998) K022889 · Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL & Siemens Infinity Explorer · Siemens Medical Solutions USA, Inc. · 2002K030738 · Siemens Multiview Infinity Telemetry System · Siemens Medical Solutions USA, Inc. · 20031990200020102020
  1. Root · 5 generations backK946306 Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring SystemSiemens Medical Solutions USA, Inc. · 1995
  2. 4 generations backK982730 SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
  3. 3 generations backK983632 Siemens SC 8000 Bedside MonitorSiemens Medical Solutions USA, Inc. · 1998
  4. 2 generations backK022889 Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC…Siemens Medical Solutions USA, Inc. · 2002
  5. 1 generation backK030738 Siemens Multiview Infinity Telemetry SystemSiemens Medical Solutions USA, Inc. · 2003
  6. This deviceK060307 12 RL AlgorithmGe Medical Systems Information Technologies · 2006
  7. Descendant · cites it directly · 4 of its ownK101521 ST/AR ST and Arrhythmia Software Model: Release K.OPhilips Medical Systems · 2010
  8. Descendant · 2 generations on · 1 of its ownK150352 V Series Monitoring System (including V12 and V21 Monitors)Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015
  9. Descendant · 2 generations on · 0 of its ownK153448 Passport Series Patient Monitors (Including Passport 8, Passport 12)Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2016 · Recalled
  10. Descendant · 2 generations on · 0 of its ownK151812 Patient Monitors Various ModelsPhilips Medical Systems · 2016
  11. Descendant · 2 generations on · 0 of its ownK150082 Panorama Patient Monitoring NetworkShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · Recalled

Most influential descendants

Showing 5 of 5 · See all
  • K101521ST/AR ST and Arrhythmia Software Model: Release K.OPhilips Medical Systems · 2010 · cites it directly4descendants
  • K150352V Series Monitoring System (including V12 and V21 Monitors)Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · 2 generations on1descendant
  • K153448Passport Series Patient Monitors (Including Passport 8, Passport 12)Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2016 · 2 generations on0descendants
  • K151812Patient Monitors Various ModelsPhilips Medical Systems · 2016 · 2 generations on0descendants
  • K150082Panorama Patient Monitoring NetworkShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K946306Siemens SC 9000 Bedside Monitor, SC 9015 Bedside Mointoring SystemSiemens Medical Solutions USA, Inc.1995—
−4K982730SC 7000 & SC 9000 XL Infinity Modular Bedside MonitorSiemens Medical Solutions USA, Inc.1998—
−3K983632Siemens SC 8000 Bedside MonitorSiemens Medical Solutions USA, Inc.1998—
−2K022889Siemens Infinity Modular Monitors, Models SC 8000, SC 7000 & SC 9000XL &…Siemens Medical Solutions USA, Inc.2002—
−1K030738Siemens Multiview Infinity Telemetry SystemSiemens Medical Solutions USA, Inc.2003—
0 (this device)K06030712 RL AlgorithmGe Medical Systems Information Technologies2006—
+1K101521ST/AR ST and Arrhythmia Software Model: Release K.OPhilips Medical Systems2010—
+2K150352V Series Monitoring System (including V12 and V21 Monitors)Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2015—
+2K153448Passport Series Patient Monitors (Including Passport 8, Passport 12)Shenzhen Mindray Bio-Medical Electronics Co., Ltd.20162
+2K151812Patient Monitors Various ModelsPhilips Medical Systems2016—
+2K150082Panorama Patient Monitoring NetworkShenzhen Mindray Bio-Medical Electronics Co., Ltd.20151

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199030
199120
199210
199320
199410
199520
199610
199730
199840
199930
200020
200230

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201520
201620
FIG. 1 — Lineage of K060307, 1995–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRT device

  1. #1 K252676 The Circadia C300 System (C300)score 15.3 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992595HP Viridia Component Monitoring System, Model Rev. K with Easi-ST Segment Measurement…
Summary page 1
…21 CFR 870.2920 Transmitters and Receivers, Electrocardiograph, Telephone 74DXH Predicate Device: 1 K992595 1 EASI 1 Philips 2 K030738 2 TruST 2 Siemens…
Hewlett-Packard GmbH1999—
*K030738Siemens Multiview Infinity Telemetry System
Summary page 1
…Electrocardiograph, Telephone 74DXH Predicate Device: 1 K992595 1 EASI 1 Philips 2 K030738 2 TruST 2 Siemens 3 K964750 3 Marquette Eagle 4000 3 GE Medical Systems…
Siemens Medical Solutions USA, Inc.2003—
*K964750Eagle 4000 Patient Monitor
Summary page 1
…ice: 1 K992595 1 EASI 1 Philips 2 K030738 2 TruST 2 Siemens 3 K964750 3 Marquette Eagle 4000 3 GE Medical Systems In format…
Marquette Electronics, Inc.1997—

Also cleared against K992595: 3 other devices →

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101521ST/AR ST and Arrhythmia Software Model: Release K.OPhilips Medical Systems20104

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 3.2 years on median.
  • None of the 33 ancestors has a recall.
  • Of its descendants, K101521 (Philips Medical Systems, 2010) has gone furthest, with 4 descendants of its own.
  • 3 other devices also cite its predicate K992595.

How does its category compare?

All DRT devices

DRT Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DRT

1in 2025

2007: 12008: 12009: 62010: 32011: 32012: 12013: 12015: 12016: 12017: 12018: 12019: 12021: 22022: 12023: 12024: 32025: 12026 (partial year): 5
2007high 6 (2009) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRT

228in 2024

2009: 70 days median2010: 44 days median2011: 149 days median2024: 228 days median2026 (partial year): 120 days median
2007high 228 (2024) · low 44 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRT

1in 2024

2011: 12021: 12024: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRT

40in 2025

2007: 1132008: 992009: 1182010: 632011: 362012: 472013: 162014: 262015: 482016: 552017: 1592018: 2242019: 4472020: 502021: 852022: 352023: 472024: 292025: 40
2007high 447 (2019) · low 16 (2013)2025

MAUDE reports naming product code DRT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—0113
20081—099
20096700118
2010344063
20113149136
20121—047
20131—016
20140—026
20151—048
20161—055
20171—0159
20181—0224
20191—0447
20200—050
20212—185
20221—035
20231—047
20243228129
20251—040
202651200—

What is it indicated for?

The GE 12RL program generates a 12-lead ECG report from a subset of the electrodes used to acquire a standard '12 lead ECG. Four of the precordial channels of the 12-lead ECG (V2, V3, V4, V6) are not acquired from the patient; rather, they are reconstructed from information that is directly recorded in the other channels of the 12-lead ECG. The four signals generated by the GE 12RL program are similar but not identical to the standard 12-lead ECG. All…

Read the full statement (165 words)

The GE 12RL program generates a 12-lead ECG report from a subset of the electrodes used to acquire a standard '12 lead ECG. Four of the precordial channels of the 12-lead ECG (V2, V3, V4, V6) are not acquired from the patient; rather, they are reconstructed from information that is directly recorded in the other channels of the 12-lead ECG.

The four signals generated by the GE 12RL program are similar but not identical to the standard 12-lead ECG. All ECG data generated via 12RL are clearly identified as to which channels have been synthesized.

The GE 12RL program is intended for use in a monitoring environment. Computerized measurements may be generated from these data; however, a computerized interpretation will not.

The product is intended for use in the general adult population ranging from healthy subjects to patients with cardiac and/or non-cardiac abnormalities.

The product is to be uscd in conjunction with the patient's clinical history, symptoms, and other diagnostic tests for final clinical judgment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K060307: 12 RL Algorithm.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K060307

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026