510(k) · Cleared
ClearedAG-Plus, Model 91210
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medel S.P.A. · CAF Nebulizer (Direct Patient Interface)
Cleared on Jun 22, 2006 after a 127-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Jun 22, 2006
- Review
- 127 days
- Class
- Class II
- Product code
- CAF
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CAF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CAF device
- #1 K260270 FindAir ONE for pMDI (FAO-MDI-V12-GRE-001)score 13.2 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All CAF devicesCAF Nebulizer (Direct Patient Interface): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CAF
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · CAF
211in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CAF
1in 2018
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · CAF
191in 2025
MAUDE reports naming product code CAF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 98 | 1 | 26 |
| 2008 | 12 | 123 | 0 | 11 |
| 2009 | 8 | 163 | 0 | 15 |
| 2010 | 10 | 114 | 0 | 37 |
| 2011 | 10 | 157 | 1 | 237 |
| 2012 | 9 | 126 | 0 | 138 |
| 2013 | 9 | 238 | 0 | 217 |
| 2014 | 9 | 151 | 5 | 123 |
| 2015 | 8 | 186 | 3 | 166 |
| 2016 | 5 | 186 | 1 | 201 |
| 2017 | 8 | 253 | 14 (13) | 256 |
| 2018 | 9 | 161 | 1 | 162 |
| 2019 | 3 | 266 | 0 | 185 |
| 2020 | 6 | 219 | 0 | 117 |
| 2021 | 8 | 324 | 0 | 161 |
| 2022 | 4 | 176 | 0 | 55 |
| 2023 | 8 | 279 | 0 | 107 |
| 2024 | 4 | 251 | 0 | 102 |
| 2025 | 7 | 211 | 0 | 191 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The intended use of the AG PLUS is to convert liquid medication into a fine mist that can be drawn into the lungs to treat respiratory conditions for adult and pediatric patients who have been prescribed inhalation therapy or medication. The AG PLUS compressor is to be used only with specific 510(k) cleared nebulizer whose input specifications may be met by the pressure and flow characteristics of the AG PLUS compressor. The initial nebulizer distributed…
Read the full statement (122 words)
The intended use of the AG PLUS is to convert liquid medication into a fine mist that can be drawn into the lungs to treat respiratory conditions for adult and pediatric patients who have been prescribed inhalation therapy or medication.
The AG PLUS compressor is to be used only with specific 510(k) cleared nebulizer whose input specifications may be met by the pressure and flow characteristics of the AG PLUS compressor. The initial nebulizer distributed with the AG PLUS compressor will be the Medel Jet Pro, the performance of which is contained in this 510(k) notification.
The AG PLUS is transportable equipment intended for home health care use.
The AG PLUS is not intended as a life sustaining or life support device.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K060404 · printed Nov 6, 2026
Cite this page
510(k) Report. “K060404: AG-Plus, Model 91210.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K060404
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026