Recalled · Class II · 2013Dimension Tacr Flex Reagent Cartridge, Model DF107
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dade Behring, Inc. · MLM Enzyme Immunoassay, Tracrolimus
Cleared on May 18, 2006 as substantially equivalent to P970007 (Abbott Laboratories, 1997) after an 83-day review. Its family tree reaches back 1 generation to 1997. It has been recalled 3 times.
- Decided
- May 18, 2006
- Review
- 83 days
- Class
- Class II
- Product code
- MLM
- Recalls
- 3
- Predicates
- 1
Its longest line of descent runs back 1 generation to P970007 (1997). No later device cites it as a predicate yet.
- Root · 1 generation backP970007 Imx Tacrolimus II AssayAbbott Laboratories · 1997 · Recalled
- This deviceK060502 Dimension Tacr Flex Reagent Cartridge, Model DF107Dade Behring, Inc. · 2006
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | P970007 | Imx Tacrolimus II Assay | Abbott Laboratories | 1997 | 2 |
| 0 (this device) | K060502 | Dimension Tacr Flex Reagent Cartridge, Model DF107 | Dade Behring, Inc. | 2006 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MLM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MLM device
- #1 K203833 Tacrolimus Assay Kitscore 5.0 · 2 generations · no Class I recall
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | P970007 | Imx Tacrolimus II AssaySummary page 1…ame / Classification Dimension® TACR Flex® reagent cartridge / Class II 3. Identification of the Predicate Device Abbott IMx® Tacrolimus II Assay, P970007 (Note: Tacrolimus test systems have been reclassified into Class II since the predicate was approved.) 4. Dev… | 1997 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jul 1, 2013 | Class II | Z-1924-2013 | Process control | Siemens initiated a recall due to confirmed complaints of low patient sample recovery with Dimension TACR Flex Reagent cartridge (DF107) lot BB4087 and its linked calibrator (DC 107) lot 3BD029. Falsely low Tacrolimus results across the… |
| Nov 27, 2012 | Class II | Z-0957-2013 | Process control | Siemens has confirmed customer complaints of low patient sample recovery with Dimension(R) TACR Flex(R) lot FA3085. Quality Control (QC) materials have not exhibited low recovery of the same magnitude. Internal method regression testing… |
| Jun 15, 2010 | Not classified | Z-2407-2010 | Other | Low patient sample recovery results in all affected lots, with possibility of inappropriate increase in tacrolimus dosage based on false low result. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has a recall.
- 4 other devices also cite its predicate P970007.
How does its category compare?
All MLM devicesMLM Enzyme Immunoassay, Tracrolimus: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MLM
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · MLM
Too few MLM 510(k)s in any year since 2007 to give a median.
Recalls per year · MLM
1in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MLM
8in 2025
MAUDE reports naming product code MLM, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 4 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 2 | 5 |
| 2011 | 0 | — | 0 | 4 |
| 2012 | 0 | — | 1 | 31 |
| 2013 | 1 | — | 1 | 75 |
| 2014 | 0 | — | 0 | 6 |
| 2015 | 1 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 2 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 1 | — | 0 | 26 |
| 2019 | 0 | — | 0 | 7 |
| 2020 | 0 | — | 0 | 4 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 0 | — | 0 | 23 |
| 2023 | 1 | — | 0 | 54 |
| 2024 | 0 | — | 0 | 62 |
| 2025 | 0 | — | 0 | 8 |
| 2026 | 0 | — | 1 | — |
What is it indicated for?
The Dimension® TACR Flex® reagent cartridge is an in vitro diagnostic test intended to quantitatively measure tacrolimus in human whole blood on the Dimension® clinical chemistry system. Measurements of tacrolimus are used as an aid in the management of tacrolimus therapy in kidney and liver transplant patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K060502 · printed Nov 5, 2026
Cite this page
510(k) Report. “K060502: Dimension Tacr Flex Reagent Cartridge, Model DF107.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K060502
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026