510(k) · Cleared
ClearedSinmed Positioning Devices
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sinmed BV · IYE Accelerator, Linear, Medical
Cleared on Mar 31, 2006 as substantially equivalent to K933613 (Bionix Development Corp., 1993) and 6 other predicates after an 11-day review. Its family tree reaches back 2 generations to 1991. 17 later devices descend from it.
- Decided
- Mar 31, 2006
- Review
- 11 days
- Class
- Class II
- Product code
- IYE
- Recalls
- None
- Predicates
- 7
Its longest line of descent runs back 2 generations to K905007 (1991). 9 ancestors in all. 17 later devices descend from it, 4 citing it directly.
- Root · 2 generations backK905007 Standard Breast Boards; Deluxe Breast BoardBionix Development Corp. · 1991
- 1 generation backK030051 Versaboard, Model 7040Bionix Development Corp. · 2003
- This deviceK060737 Sinmed Positioning DevicesSinmed BV · 2006
- Descendant · cites it directly · 14 of its ownK093738 Mri Patient Positioning DevicesMedtec, Inc. · 2010
- Descendant · 2 generations on · 13 of its ownK111340 Head and Neck Immobilization System, Body Immobilization SystemMedtec, Inc. · 2011
- Descendant · cites it directly · 7 of its ownK142420 Patient Positioning DevicesMacromedics BV · 2015
- Descendant · 3 generations on · 5 of its ownK122888 CDR Systems Precision Patient Positioning SystemCdr Systems, Inc. · 2013
- Descendant · 4 generations on · 3 of its ownK153026 Body Pro-Lok Respiratory Plate, Respiratory Plate Cushion, Body…Medtec, Inc. D/B/A Civco Medical Solutions · 2016
Showing 5 of 17 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 17 · See all- K093738Mri Patient Positioning DevicesMedtec, Inc. · 2010 · cites it directly14descendants
- K111340Head and Neck Immobilization System, Body Immobilization SystemMedtec, Inc. · 2011 · 2 generations on13descendants
- K142420Patient Positioning DevicesMacromedics BV · 2015 · cites it directly7descendants
- K122888CDR Systems Precision Patient Positioning SystemCdr Systems, Inc. · 2013 · 3 generations on5descendants
- K153026Body Pro-Lok Respiratory Plate, Respiratory Plate Cushion, Body Pro-Respiratory Belt…Medtec, Inc. D/B/A Civco Medical Solutions · 2016 · 4 generations on3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K905007 | Standard Breast Boards; Deluxe Breast Board | Bionix Development Corp. | 1991 | — |
| −1 | K030051 | Versaboard, Model 7040 | Bionix Development Corp. | 2003 | — |
| 0 (this device) | K060737 | Sinmed Positioning Devices | Sinmed BV | 2006 | — |
| +1 | K093738 | Mri Patient Positioning Devices | Medtec, Inc. | 2010 | — |
| +2 | K111340 | Head and Neck Immobilization System, Body Immobilization System | Medtec, Inc. | 2011 | — |
| +1 | K142420 | Patient Positioning Devices | Macromedics BV | 2015 | — |
| +3 | K122888 | CDR Systems Precision Patient Positioning System | Cdr Systems, Inc. | 2013 | — |
| +4 | K153026 | Body Pro-Lok Respiratory Plate, Respiratory Plate Cushion, Body… | Medtec, Inc. D/B/A Civco Medical Solutions | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
| 1994 | 3 | 0 |
| 1995 | 1 | 0 |
| 1998 | 1 | 0 |
| 2002 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 2 | 0 |
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
| 2013 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYE device
- #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (7)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K933613 | 3-Way Head Immobilizer; 3WAY Deluxe Reusable Frame Head ImmobilizerSummary page 1…DeLuxe Reusable Frame, manufactured by Bionix Development corporation. Registration number: 1526854) and cleared by FDA with K933613 Description of the devices: See Sinmed Page: Product: product Catalogue 2006 4 -Posifix 1,… | 1993 |
| * | K030051 | Versaboard, Model 7040Summary page 3…manufactured by Bionix Development Corporation, Registration number: 1526854) and cleared by FDA with K030051 Description of the devices: See Sinmed Page: Product: product Catalogue 2006 8 Posifix-E… | 2003 |
| * | K974703 | Carbon Fiber Breast BoardSummary page 5…BOARD, manufactured by MED-TEC.INC. (Registration number: 1932738) and cleared by FDA with K974703. Description of the devices: See Sinmed Page: Product: product Catalogue 2006 27 Thoraw… | 1998 |
| * | K023293 | Med-Tec Bellyboard, Models MT-Bba-01 & MT-Bba-02Summary page 7…Bellyboard, manufactured by MedTec. INC. (Registration number: 1932738) and cleared by FDA with K023293. Description of the devices: See Sinmed Page: Product: product Catalogue 2006 31 Bellyboa… | 2002 |
| * | K950866 | Hip Fixation SystemSummary page 9…System manufactured by MedTec. INC. (Registration number: 1932738) and cleared by FDA with K950866. Description of the devices: See Sinmed Page: Product: product Catalogue 2006 36 Posifix… | 1995 |
| * | K935300 | Vac-Lok Immobilization SystemSummary page 11…manufactured by Med-Tec INC. (Registration number: 1932738) and cleared by FDA with K(935300. Description of the devices: See Sinnmed Page: Product: product Catalogue 2006 45 R… | 1994 |
| * | K926187 | Posicast Immobilization SystemSummary page 13…registered by Huestis Machine Corporation. (Registration number: 1219183) and cleared by FDA with K9261 87. The following table compares the Sinred POSICAST IMMOBILIZATION SYSTEM and the predicate dev… | 1994 |
What descends from it? (17)
See all 174 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 2 companies; a new generation was cleared every 12.1 years on median.
- 1 of the 9 ancestors has a recall of any class.
- Of its descendants, K093738 (Medtec, Inc., 2010) has gone furthest, with 14 descendants of its own.
How does its category compare?
All IYE devicesIYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · IYE
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYE
170in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IYE
101in 2025
MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 23 | 44 | 78 | 155 |
| 2008 | 14 | 69 | 49 | 114 |
| 2009 | 20 | 63 | 22 | 174 |
| 2010 | 23 | 74 | 27 | 246 |
| 2011 | 11 | 94 | 73 | 280 |
| 2012 | 28 | 106 | 20 | 128 |
| 2013 | 18 | 88 | 11 | 96 |
| 2014 | 20 | 100 | 14 | 124 |
| 2015 | 20 | 108 | 8 | 100 |
| 2016 | 21 | 97 | 7 | 97 |
| 2017 | 23 | 94 | 7 | 125 |
| 2018 | 21 | 58 | 7 | 85 |
| 2019 | 19 | 83 | 2 | 91 |
| 2020 | 20 | 67 | 4 | 74 |
| 2021 | 19 | 86 | 5 | 68 |
| 2022 | 12 | 172 | 3 | 66 |
| 2023 | 18 | 129 | 7 | 128 |
| 2024 | 9 | 239 | 1 | 81 |
| 2025 | 12 | 170 | 1 | 101 |
| 2026 | 14 | 120 | 4 | — |
What is it indicated for?
Fixation and (re)positioning of the head- and neck area of the patient during radiotherapy and diagnostics.
Fixation and (re~positioning of the head- and neck area of the patient during radiotherapy and diagnostics.
Positioning of the lung- and thorax area of the patient during radiotherapy and diagnostics.
Positioning of the lower abdomen of a patient during radiotherapy and diagnostics.
Positioning of hip and lower extremities of a patient during radiotherapy and diagnostics.
Fixation and (re~positioning of the patient during radiotherapy and diagnostics,
Fixation and (re)positioning of the patient during radiotherapy and diagnostics.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K060737 · printed Nov 4, 2026
Cite this page
510(k) Report. “K060737: Sinmed Positioning Devices.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K060737
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026