510(k) Report

510(k) · Cleared

Recalled · 2008

Insure II

K060930510(k) SpecialCleared May 4, 200629-day reviewClass II21 CFR 864.6550Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Enterix, Inc. · KHE Reagent, Occult Blood

Cleared on May 4, 2006 after a 29-day review. FDA’s file for it is a 510(k) statement, which names no predicate. It has been recalled once.

Decided
May 4, 2006
Review
29 days
Class
Class II
Product code
KHE
Recalls
1
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K060930Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KHE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 3, 2008Not classifiedZ-0480-2009OtherFalse readings: Reduced sensitivity could affect the test line area and/or control line on the test strips, which may lead to inaccurate results. For further information, please contact Enterix, Inc. at 1-800-531--3681.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KHE devices

KHE Reagent, Occult Blood: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KHE

1in 2018

2007: 32008: 32010: 22011: 22012: 22015: 12017: 42018: 1
2007high 4 (2017) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KHE

126in 2017

2007: 104 days median2008: 93 days median2017: 126 days median
2007high 126 (2017) · low 93 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KHE

2in 2025

2008: 12011: 62013: 22018: 12020: 12025: 2
2007high 6 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KHE

3in 2025

2007: 32008: 52009: 52010: 42011: 42012: 32013: 162014: 62015: 102016: 32017: 12018: 12019: 12020: 12021: 22023: 12024: 22025: 3
2007high 16 (2013) · low 0 (2022)2025

MAUDE reports naming product code KHE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007310403
200839315
20090—05
20102—04
20112—64
20122—03
20130—216
20140—06
20151—010
20160—03
2017412601
20181—11
20190—01
20200—11
20210—02
20220—00
20230—01
20240—02
20250—23
20260—0—

What is it indicated for?

InSure® [ I FIT is a fecal immunochemical test (FIT) that qualitatively detects human hemoglobin from blood in fecal samples. The samples will generally be collected by the test subject at home and the test developed at laboratories or professional offices. Fecal immunochemical tests are useful screening aids for detecting primarily lower gastrointestinal (g.i.) disorders that may be related to iron deficiency anemia, diverticulitis, ulcerative colitis…

Read the full statement (103 words)

InSure® [ I FIT is a fecal immunochemical test (FIT) that qualitatively detects human hemoglobin from blood in fecal samples. The samples will generally be collected by the test subject at home and the test developed at laboratories or professional offices. Fecal immunochemical tests are useful screening aids for detecting primarily lower gastrointestinal (g.i.) disorders that may be related to iron deficiency anemia, diverticulitis, ulcerative colitis, polyps, adenomas, colorectal cancers or other g.i. lesions that can bleed. Health professionals recommend InSure II for use as part of routine physical examinations and in screening for colorectal cancer or other sources of lower g.i. bleeding.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K060930: Insure II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K060930

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026