510(k) Report

510(k) · Cleared

Cleared

Caas MRV Version 3.0

K060941510(k) SpecialCleared Apr 19, 200613-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pie Medical Imaging BV · LLZ System, Image Processing, Radiological

Cleared on Apr 19, 2006 as substantially equivalent to K994283 (Medis Medical Imaging Systems BV, 2000) after a 13-day review. Its family tree reaches back 3 generations to 1994. 4 later devices descend from it.

Decided
Apr 19, 2006
Review
13 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K940172 (1994). 4 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2016: 1 descendant cleared2018: 1 descendant cleared2024: 1 descendant clearedK940172 · Cardiovascular Measurement System-CMS · Medis Medical Imaging Systems, Inc. · 1994K993765 · Quantitative Analysis of Left Ventricular Angiograms (QLV) · Medis Medical Imaging Systems BV · 1999K994283 · Mri- Magnetic Resonance Analytical Software System · Medis Medical Imaging Systems BV · 20001990200020102020
  1. Root · 3 generations backK940172 Cardiovascular Measurement System-CMSMedis Medical Imaging Systems, Inc. · 1994
  2. 2 generations backK993765 Quantitative Analysis of Left Ventricular Angiograms (QLV)Medis Medical Imaging Systems BV · 1999
  3. 1 generation backK994283 Mri- Magnetic Resonance Analytical Software SystemMedis Medical Imaging Systems BV · 2000
  4. This deviceK060941 Caas MRV Version 3.0Pie Medical Imaging BV · 2006
  5. Descendant · cites it directly · 2 of its ownK162112 Caas MRVPie Medical Imaging BV · 2016
  6. Descendant · cites it directly · 2 of its ownK090155 Caas MR Flow 1.0Pie Medical Imaging BV · 2009
  7. Descendant · 2 generations on · 1 of its ownK181825 CAAS MR SolutionsPie Medical Imaging BV · 2018
  8. Descendant · 3 generations on · 0 of its ownK232007 CAAS MR SolutionsPie Medical Imaging BV · 2024

Most influential descendants

Showing 4 of 4 · See all
  • K162112Caas MRVPie Medical Imaging BV · 2016 · cites it directly2descendants
  • K090155Caas MR Flow 1.0Pie Medical Imaging BV · 2009 · cites it directly2descendants
  • K181825CAAS MR SolutionsPie Medical Imaging BV · 2018 · 2 generations on1descendant
  • K232007CAAS MR SolutionsPie Medical Imaging BV · 2024 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K940172Cardiovascular Measurement System-CMSMedis Medical Imaging Systems, Inc.1994—
−2K993765Quantitative Analysis of Left Ventricular Angiograms (QLV)Medis Medical Imaging Systems BV1999—
−1K994283Mri- Magnetic Resonance Analytical Software SystemMedis Medical Imaging Systems BV2000—
0 (this device)K060941Caas MRV Version 3.0Pie Medical Imaging BV2006—
+1K162112Caas MRVPie Medical Imaging BV2016—
+1K090155Caas MR Flow 1.0Pie Medical Imaging BV2009—
+2K181825CAAS MR SolutionsPie Medical Imaging BV2018—
+3K232007CAAS MR SolutionsPie Medical Imaging BV2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201610
201810
202410
FIG. 1 — Lineage of K060941, 1994–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K994283Mri- Magnetic Resonance Analytical Software System
Summary page 1
…y Class II. The CAAS MRV software package is substantially equivalent to the quantitative analysis software package MRI-Magnetic resonance Analytical Software System, K994283. The CAAS MRV is a software tool designed for the fimctional analysis of the heart based on multi-slice, multi-phase MR images o…
Medis Medical Imaging Systems BV2000—

Also cleared against K994283: 7 other devices →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K162112Caas MRVPie Medical Imaging BV20162
K090155Caas MR Flow 1.0Pie Medical Imaging BV20092

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 5.2 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K162112 (Pie Medical Imaging BV, 2016) has gone furthest, with 2 descendants of its own.
  • 7 other devices also cite its predicate K994283.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

1. Delineate the inner and outer wall of the ventricles automatically, semi-automatically or manually, as well as the papillary muscles, on different kinds of MRI images.

2. Derive from these images and contours quantitative information to be used to assist in cardiac analysis

The CAAS MRV has been designed to be used in everyday clinical practice to support clinical diagnoses, as well as for research purposes like clinical research trials.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K060941: Caas MRV Version 3.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K060941

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026