510(k) · Cleared
ClearedSpeedflow 0.2UM Filter, Model 11214; Speedflow 1.2UM Filter, Model 11215; Easydrop Controller, Model 11216
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Gvs Spa · FPA Set, Administration, Intravascular
Cleared on Jun 30, 2006 after a 70-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.
- Decided
- Jun 30, 2006
- Review
- 70 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK061115 Speedflow 0.2UM Filter, Model 11214; Speedflow 1.2UM Filter, Model…Gvs Spa · 2006
- Descendant · cites it directly · 0 of its ownK181870 Infusion Sets with Precision Filter for Single Use, Precision…Wuhan W.E.O Science & Technology Development Co., Ltd. · 2019
- Descendant · cites it directly · 0 of its ownK080695 Mobile I.V. Systems 10,20,60Northwind Technologies, Corp. · 2008
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K061115 | Speedflow 0.2UM Filter, Model 11214; Speedflow 1.2UM Filter, Model 11215… | Gvs Spa | 2006 | — |
| +1 | K181870 | Infusion Sets with Precision Filter for Single Use, Precision Infusion Filter… | Wuhan W.E.O Science & Technology Development Co., Ltd. | 2019 | — |
| +1 | K080695 | Mobile I.V. Systems 10,20,60 | Northwind Technologies, Corp. | 2008 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
| 2019 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | B. Braun; Filterflow Filtered Extension Sets Named without a submission number | |
| * | — | Amsino; IN. Administration Sets Named without a submission number | |
| * | — | Leventon; I.V. Extension Sets with I.V. Flow Regulators Named without a submission number |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K181870 (Wuhan W.E.O Science & Technology Development Co., Ltd., 2019) has gone furthest, with 0 descendants of its own.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
Indicated as a single use, sterile device for use in I.V. therapy when an extended fluid path is required for administration. Environment of use: Hospital, Emergency Medical Services settings, wherever I.V. fluid administration may be indicated.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061115 · printed Nov 6, 2026
Cite this page
510(k) Report. “K061115: Speedflow 0.2UM Filter, Model 11214; Speedflow 1.2UM Filter, Model 11215; Easydrop Controller, Model 11216.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061115
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026