510(k) Report

510(k) · Cleared

Cleared

Functional Anaesthetic Discography (Fad) Catheter System, Model D01A ; Introducer Needle, Model D01B

K061210510(k) SpecialCleared Jun 27, 200657-day reviewClass II21 CFR 868.5150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kyphon, Inc. · BSP Needle, Conduction, Anesthetic (W/Wo Introducer)

Cleared on Jun 27, 2006 as substantially equivalent to K043500 (Innospine, Inc., 2005) after a 57-day review. Its family tree reaches back 7 generations to 1990. 3 of the 33 devices in its family, counting itself, have a Class I recall. 2 later devices descend from it.

Decided
Jun 27, 2006
Review
57 days
Class
Class II
Product code
BSP
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K896422 (1990). 30 ancestors in all, the oldest K801912 (1980). 2 later devices descend from it, 2 citing it directly. 3 of the 33 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2003: 1 other ancestor2002: 2 other ancestors1996: 3 other ancestors1997: 2 other ancestors1995: 2 other ancestors1993: 3 other ancestors1992: 2 other ancestors, 1 with a Class I recall11991: 1 other ancestor, 1 with a Class I recall11981: 2 other ancestors1999: 1 other ancestor1998: 1 other ancestor1984: 1 other ancestor1980: 1 other ancestor, 1 with a Class I recall12007: 1 descendant cleared2008: 1 descendant clearedK896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990×3: 3 generations cleared close together, K980558 (1998), K982946 (1998), K984502 (1999) K030830 · B. Braun Nerve Block Catheter · B.Braun Medical, Inc. · 2003K042488 · Perifix Catheter and Contiplex Catheter · B.Braun Medical, Inc. · 2004K043500 · Functional Anaesthetic Discography (Fad) System, Including Fad Catheter Kit and Fad Introducer Needle · Innospine, Inc. · 2005 · recalled19801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 5 other ancestors3 generations back: 10 other ancestors, 2 with a Class I recall24 generations back: 3 other ancestors5 generations back: 4 other ancestors, 1 with a Class I recall16 generations back: 1 other ancestor 1 generation forward: 2 descendants K043500 · Functional Anaesthetic Discography (Fad) System, Including Fad Catheter Kit and Fad Introducer Needle · Innospine, Inc. · 2005 · recalledK042488 · Perifix Catheter and Contiplex Catheter · B.Braun Medical, Inc. · 2004K030830 · B. Braun Nerve Block Catheter · B.Braun Medical, Inc. · 2003K984502 · Nerve Block Infusion Kit · I-Flow Corp. · 1999K982946 · Painbuster Infusion Kit · I-Flow Corp. · 1998K980558 · Painbuster Infusion System · I-Flow Corp. · 1998K896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990−50
  1. Root · 7 generations backK896422 Burron Ambulatory Drug Delivery SystemBurron Medical, Inc. · 1990
  2. 6 generations backK980558 Painbuster Infusion SystemI-Flow Corp. · 1998
  3. 5 generations backK982946 Painbuster Infusion KitI-Flow Corp. · 1998
  4. 4 generations backK984502 Nerve Block Infusion KitI-Flow Corp. · 1999
  5. 3 generations backK030830 B. Braun Nerve Block CatheterB.Braun Medical, Inc. · 2003
  6. 2 generations backK042488 Perifix Catheter and Contiplex CatheterB.Braun Medical, Inc. · 2004
  7. 1 generation backK043500 Functional Anaesthetic Discography (Fad) System, Including Fad…Innospine, Inc. · 2005 · Recalled
  8. This deviceK061210 Functional Anaesthetic Discography (Fad) Catheter System, Model D01A…Kyphon, Inc. · 2006
  9. Descendant · cites it directly · 1 of its ownK063071 Discyphor Catheter System, Model D01A; Discyphor Introducer Needle…Kyphon, Inc. · 2007
  10. Descendant · cites it directly · 0 of its ownK073516 Discyphor Direct Catheter System, Discyphor Direct Needles, Long…Kyphon, Inc. · 2008

Class I recalls in this family

Most influential descendants

Showing 2 of 2 · See all
  • K063071Discyphor Catheter System, Model D01A; Discyphor Introducer Needle, Model D01BKyphon, Inc. · 2007 · cites it directly1descendant
  • K073516Discyphor Direct Catheter System, Discyphor Direct Needles, Long, Discyphor Direct…Kyphon, Inc. · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K896422Burron Ambulatory Drug Delivery SystemBurron Medical, Inc.1990—
−6K980558Painbuster Infusion SystemI-Flow Corp.1998—
−5K982946Painbuster Infusion KitI-Flow Corp.1998—
−4K984502Nerve Block Infusion KitI-Flow Corp.1999—
−3K030830B. Braun Nerve Block CatheterB.Braun Medical, Inc.2003—
−2K042488Perifix Catheter and Contiplex CatheterB.Braun Medical, Inc.2004—
−1K043500Functional Anaesthetic Discography (Fad) System, Including Fad Catheter Kit…Innospine, Inc.20051
0 (this device)K061210Functional Anaesthetic Discography (Fad) Catheter System, Model D01A…Kyphon, Inc.2006—
+1K063071Discyphor Catheter System, Model D01A; Discyphor Introducer Needle, Model D01BKyphon, Inc.2007—
+1K073516Discyphor Direct Catheter System, Discyphor Direct Needles, Long, Discyphor…Kyphon, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198011
198120
198410
199111
199221
199330
199520
199630
199720
199810
199910
200220
200310
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
200810
FIG. 1 — Lineage of K061210, 1990–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BSP device

  1. #1 K241954 SonoBlock; SonoBlock IIscore 11.0 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K043500Functional Anaesthetic Discography (Fad) System, Including Fad Catheter Kit and Fad…
Summary page 1
…: 1221 Crossman Avenue Sunnyvale, CA 94089 Phone: (408) 548-5421 eDevice(s): K043500, Functional Anaesthetic Discography (F.A.D.) Catheter System, cleared on April 15, 2005. Intended…
Innospine, Inc.20051

Also cleared against K043500: 2 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K063071Discyphor Catheter System, Model D01A; Discyphor Introducer Needle, Model D01BKyphon, Inc.20071
K073516Discyphor Direct Catheter System, Discyphor Direct Needles, Long, Discyphor Direct…Kyphon, Inc.20080

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K911202Atraumatic Standard Sprotte NeedlePajunk GmbH · 1992 · 3 generations back · ◆ in the 1992 ancestors bar of FIG. 11 Class I recall
  • K911260Atraumatic Standard Sprotte NeedlePajunk GmbH · 1991 · 3 generations back · ◆ in the 1991 ancestors bar of FIG. 11 Class I recall
  • K801912Arrow Positive Placement Con/Epidural anArrow Intl., Inc. · 1980 · 5 generations back · ◆ in the 1980 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 1.2 years on median.
  • 7 of the 30 ancestors have a recall of any class; 3 have a Class I recall.
  • Of its descendants, K063071 (Kyphon, Inc., 2007) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K043500.

How does its category compare?

All BSP devices

BSP Needle, Conduction, Anesthetic (W/Wo Introducer): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BSP

4in 2025

2007: 32008: 82009: 52010: 32011: 32012: 32013: 22014: 22015: 22016: 62017: 42018: 82019: 22020: 32021: 32022: 22024: 32025: 4
2007high 8 (2008) · low 0 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BSP

170in 2025

2007: 189 days median2008: 127 days median2009: 97 days median2010: 79 days median2011: 114 days median2012: 148 days median2016: 268 days median2017: 186 days median2018: 241 days median2020: 269 days median2021: 265 days median2024: 70 days median2025: 170 days median
2007high 269 (2020) · low 70 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BSP

1in 2020

2016: 12019: 12020: 12026 (partial year): 1, 1 Class I
2007high 1 (2016) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · BSP

86in 2025

2007: 262008: 242009: 302010: 492011: 332012: 202013: 322014: 412015: 382016: 1522017: 342018: 692019: 862020: 782021: 522022: 842023: 752024: 662025: 86
2007high 152 (2016) · low 20 (2012)2025

MAUDE reports naming product code BSP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073189026
20088127024
2009597030
2010379049
20113114033
20123148020
20132—032
20142—041
20152—038
201662681152
20174186034
20188241069
20192—186
20203269178
20213265052
20222—084
20230—075
2024370066
20254170086
20260—1 (1)—

What is it indicated for?

The Functional Anaesthetic Discography (FAD) Catheter System is intended for use in delivering either a single dose or continuous administration of a radiopaque contrast, local anaesthetics, and/or saline solution to the intradiscal space.

The Functional Anaesthetic Discography (FAD) Introducer Needle is intended for use to access the area adjacent to the intradiscal space for the purpose of facilitating placement of the FAD Catheter and Guidewire into the intradiscal space.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061210: Functional Anaesthetic Discography (Fad) Catheter System, Model D01A ; Introducer Needle, Model D01B.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061210

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026