510(k) · Cleared
Recalled · 2011Purewrist Scissors, Model PW1101-01;Purewrist Dissector, Model PW1201-01;Purewrist Hook, Model PW1301-01
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cambridge Endoscopic Devices · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Aug 10, 2006 as substantially equivalent to K984240 (Ethicon Endo-Surgery, Inc., 1999) after a 79-day review. Its family tree reaches back 2 generations to 1991. 14 later devices descend from it. It has been recalled 2 times.
- Decided
- Aug 10, 2006
- Review
- 79 days
- Class
- Class II
- Product code
- GEI
- Recalls
- 2
- Predicates
- 1
Its longest line of descent runs back 2 generations to K910831 (1991). 14 later devices descend from it, 5 citing it directly.
- Root · 2 generations backK910831 Endopath Surgical InstrumentsSymbiosis Corp. · 1991
- 1 generation backK984240 Endopath Endoscopic InstrumentsEthicon Endo-Surgery, Inc. · 1999 · Recalled
- This deviceK061425 Purewrist Scissors, Model PW1101-01;Purewrist Dissector, Model…Cambridge Endoscopic Devices · 2006
- Descendant · cites it directly · 8 of its ownK173919 HX DeviceHuman Extension, Ltd. · 2018
- Descendant · 2 generations on · 3 of its ownK203603 Monopolar HookHuman Xtensions, Ltd. · 2021
- Descendant · cites it directly · 1 of its ownK173405 DiLumen Endolumenal Interventional Scissors (DiLumen Is)Lumendi, LLC · 2018
- Descendant · 2 generations on · 0 of its ownK260183 MediBot Needle Driver UnoParallel Robotics, LLC · 2026
- Descendant · 2 generations on · 0 of its ownK243968 Revolve Surgical SystemRevolve Surgical, Inc. · 2025
Showing 5 of 14 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 14 · See all- K173919HX DeviceHuman Extension, Ltd. · 2018 · cites it directly8descendants
- K203603Monopolar HookHuman Xtensions, Ltd. · 2021 · 2 generations on3descendants
- K173405DiLumen Endolumenal Interventional Scissors (DiLumen Is)Lumendi, LLC · 2018 · cites it directly1descendant
- K260183MediBot Needle Driver UnoParallel Robotics, LLC · 2026 · 2 generations on0descendants
- K243968Revolve Surgical SystemRevolve Surgical, Inc. · 2025 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K910831 | Endopath Surgical Instruments | Symbiosis Corp. | 1991 | — |
| −1 | K984240 | Endopath Endoscopic Instruments | Ethicon Endo-Surgery, Inc. | 1999 | 1 |
| 0 (this device) | K061425 | Purewrist Scissors, Model PW1101-01;Purewrist Dissector, Model… | Cambridge Endoscopic Devices | 2006 | — |
| +1 | K173919 | HX Device | Human Extension, Ltd. | 2018 | — |
| +2 | K203603 | Monopolar Hook | Human Xtensions, Ltd. | 2021 | — |
| +1 | K173405 | DiLumen Endolumenal Interventional Scissors (DiLumen Is) | Lumendi, LLC | 2018 | — |
| +2 | K260183 | MediBot Needle Driver Uno | Parallel Robotics, LLC | 2026 | — |
| +2 | K243968 | Revolve Surgical System | Revolve Surgical, Inc. | 2025 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
| 2011 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 1 | 0 |
| 2021 | 3 | 0 |
| 2023 | 3 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K984240 | Endopath Endoscopic InstrumentsSummary page 1…y laparoscopic instruments are substantially equivalent to the Ethicon Endo- Surgery, Inc. ENDOPATH-I Endoscopic Instruments dleared and under K984240. 4. Device Description The pureWrist~m electrocautery laparoscopic instruments are sterile, single use di… | 1999 |
What descends from it? (14)
See all 145 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 20, 2011 | Not classified | Z-2743-2011 | Process control | PET shrink sleeve insulation material dislodging from the distal tips of Autonomy Laparo-Angle (ALA) Metzenbaum Scissors |
| May 20, 2011 | Not classified | Z-2744-2011 | Process control | PET shrink sleeve insulation material dislodging from the distal tips of Autonomy Laparo-Angle (ALA) Metzenbaum Scissors |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 8.1 years on median.
- 1 of the 2 ancestors has a recall of any class.
- Of its descendants, K173919 (Human Extension, Ltd., 2018) has gone furthest, with 8 descendants of its own.
- 12 other devices also cite its predicate K984240.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
The pureWrist™ electrocautery laparoscopic instruments have application in a variety of minimally invasive procedures to facilitate grasping, mobilization, dissection, and transection of tissue.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061425 · printed Nov 6, 2026
Cite this page
510(k) Report. “K061425: Purewrist Scissors, Model PW1101-01;Purewrist Dissector, Model PW1201-01;Purewrist Hook, Model PW1301-01.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061425
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026