510(k) · Cleared
ClearedCTS-5500/CTS-6600 Ultrasonic Pulsed Echo Imaging System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shantou Institute of Ultrasonic Instruments (Siui · IYN System, Imaging, Pulsed Doppler, Ultrasonic
Cleared on Jun 30, 2006 as substantially equivalent to K012772 (Shantou Institute of Ultrasonic Instuments, 2001) after a 30-day review. Its family tree reaches back 2 generations to 2000.
- Decided
- Jun 30, 2006
- Review
- 30 days
- Class
- Class II
- Product code
- IYN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K000030 (2000). No later device cites it as a predicate yet.
- Root · 2 generations backK000030 Sonoace 600 Diagnostic Ultrasound SystemMedison America, Inc. · 2000
- 1 generation backK012772 CTS-485 Ultrasound Imaging SystemShantou Institute of Ultrasonic Instuments · 2001
- This deviceK061488 CTS-5500/CTS-6600 Ultrasonic Pulsed Echo Imaging SystemShantou Institute of Ultrasonic Instruments (Siui · 2006
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K000030 | Sonoace 600 Diagnostic Ultrasound System | Medison America, Inc. | 2000 | — |
| −1 | K012772 | CTS-485 Ultrasound Imaging System | Shantou Institute of Ultrasonic Instuments | 2001 | — |
| 0 (this device) | K061488 | CTS-5500/CTS-6600 Ultrasonic Pulsed Echo Imaging System | Shantou Institute of Ultrasonic Instruments (Siui | 2006 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYN device
- #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K012772 | CTS-485 Ultrasound Imaging SystemSummary page 1…Dublin, CA 94568 Telephone: 1-925-556-1302 Fax: 1-866-718-3819 Predicate Device: SlU CTS-485, K012772 Device Description: The SlUI CTS-5500/CTS-6600 is a portable diagnostic ultrasound system capable of the following operating mo… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 4.7 years on median.
- None of the 2 ancestors has a recall.
- 1 other device also cites its predicate K012772.
How does its category compare?
All IYN devicesIYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · IYN
57in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYN
124in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYN
10in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · IYN
610in 2025
MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 26 | 16 | 3 |
| 2008 | 25 | 18 | 12 | 2 |
| 2009 | 18 | 29 | 8 | 9 |
| 2010 | 29 | 67 | 10 | 17 |
| 2011 | 39 | 46 | 8 | 18 |
| 2012 | 43 | 37 | 3 | 20 |
| 2013 | 51 | 60 | 8 | 18 |
| 2014 | 56 | 39 | 2 | 48 |
| 2015 | 54 | 55 | 3 | 116 |
| 2016 | 60 | 56 | 2 | 145 |
| 2017 | 64 | 83 | 0 | 146 |
| 2018 | 59 | 85 | 7 | 85 |
| 2019 | 47 | 79 | 0 | 59 |
| 2020 | 57 | 72 | 4 | 67 |
| 2021 | 46 | 105 | 8 | 213 |
| 2022 | 53 | 105 | 10 | 186 |
| 2023 | 44 | 115 | 4 | 229 |
| 2024 | 50 | 119 | 1 | 266 |
| 2025 | 57 | 124 | 10 | 610 |
| 2026 | 44 | 107 | 2 (1) | — |
What is it indicated for?
Ultrasonic pulsed echo imaging and measurement for abdominal, pediatric, small organ, cardiac, peripheral vascular applications
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061488 · printed Nov 6, 2026
Cite this page
510(k) Report. “K061488: CTS-5500/CTS-6600 Ultrasonic Pulsed Echo Imaging System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061488
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026