510(k) Report

510(k) · Cleared

Recalled · Class II · 2025

Cell-Dyn Ruby System

K061667510(k) SpecialCleared Jul 10, 200626-day reviewClass II21 CFR 864.5220Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Laboratories · GKZ Counter, Differential Cell

Cleared on Jul 10, 2006 as substantially equivalent to K972354 (Abbott Laboratories, 1997) and 2 other predicates after a 26-day review. Its family tree reaches back 4 generations to 1982. It has been recalled 12 times.

Decided
Jul 10, 2006
Review
26 days
Class
Class II
Product code
GKZ
Recalls
12
Predicates
3

Its longest line of descent runs back 4 generations to K823355 (1982). 13 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2001: 1 other ancestor1996: 3 other ancestors1993: 1 other ancestor1995: 1 other ancestor1991: 1 other ancestor1989: 1 other ancestor1987: 1 other ancestorK823355 · Coulter-Counter #S Plus IV & Lyse S +D · Coulter Electronics, Inc. · 1982K955715 · Cell Dyn 3500 Multi-Parameter Automated Hematology Analyzer (Modification) · Abbott Laboratories · 1996 · recalledK972354 · Abbott Cell-Dyn 3200 System · Abbott Laboratories · 1997 · recalledK980614 · Abbott Cell-Dyn 3000 Series Hematology Systems · Abbott Laboratories · 1998 · recalled198019851990199520002005
  1. Root · 4 generations backK823355 Coulter-Counter #S Plus IV & Lyse S +DCoulter Electronics, Inc. · 1982
  2. 3 generations backK955715 Cell Dyn 3500 Multi-Parameter Automated Hematology Analyzer…Abbott Laboratories · 1996 · Recalled
  3. 2 generations backK972354 Abbott Cell-Dyn 3200 SystemAbbott Laboratories · 1997 · Recalled
  4. 1 generation backK980614 Abbott Cell-Dyn 3000 Series Hematology SystemsAbbott Laboratories · 1998 · Recalled
  5. This deviceK061667 Cell-Dyn Ruby SystemAbbott Laboratories · 2006
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K823355Coulter-Counter #S Plus IV & Lyse S +DCoulter Electronics, Inc.1982—
−3K955715Cell Dyn 3500 Multi-Parameter Automated Hematology Analyzer (Modification)Abbott Laboratories19961
−2K972354Abbott Cell-Dyn 3200 SystemAbbott Laboratories19976
−1K980614Abbott Cell-Dyn 3000 Series Hematology SystemsAbbott Laboratories19985
0 (this device)K061667Cell-Dyn Ruby SystemAbbott Laboratories2006—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199110
199310
199510
199630
200110
FIG. 1 — Lineage of K061667, 1982–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKZ device

  1. #1 K250943 Sysmex XR-Series (XR-10) Automated Hematology…score 13.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972354Abbott Cell-Dyn 3200 System
Summary page 1
…ion Name: Automated Differential Cell Counter (21 CRF 864.5220) Predicate Device: CELL-DYN® 3200 System K972354 - September 16, 1997 K980614 - April 24, 1998 K012934 - September 28, 2001 I…
Abbott Laboratories19976
*K980614Abbott Cell-Dyn 3000 Series Hematology Systems
Summary page 1
…(21 CRF 864.5220) Predicate Device: CELL-DYN® 3200 System K972354 - September 16, 1997 K980614 - April 24, 1998 K012934 - September 28, 2001 Intended Use: The CELL-DYN Ruby System is a m…
Abbott Laboratories19985
*K012934Cell-Dyn 3200 System with Absolute and Percent Reticulocyte
Summary page 1
…Device: CELL-DYN® 3200 System K972354 - September 16, 1997 K980614 - April 24, 1998 K012934 - September 28, 2001 Intended Use: The CELL-DYN Ruby System is a multiparameter, automated h…
Abbott Laboratories2001—

Also cleared against K972354: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 18, 2025Class IIZ-1655-2025Software change controlWhen expired reagents are scanned or manually entered, the system will change the expiration date to current or future date without notifying user that an expired reagent is being used. Use of expired reagents is against the guidelines of…
Mar 18, 2025Class IIZ-1653-2025Software change controlWhen expired reagents are scanned or manually entered, the system will change the expiration date to current or future date without notifying user that an expired reagent is being used. Use of expired reagents is against the guidelines of…
Mar 18, 2025Class IIZ-1654-2025Software change controlWhen expired reagents are scanned or manually entered, the system will change the expiration date to current or future date without notifying user that an expired reagent is being used. Use of expired reagents is against the guidelines of…
Mar 18, 2025Class IIZ-1656-2025Software change controlWhen expired reagents are scanned or manually entered, the system will change the expiration date to current or future date without notifying user that an expired reagent is being used. Use of expired reagents is against the guidelines of…
Mar 18, 2025Class IIZ-1652-2025Software change controlWhen expired reagents are scanned or manually entered, the system will change the expiration date to current or future date without notifying user that an expired reagent is being used. Use of expired reagents is against the guidelines of…
Oct 19, 2023Class IIZ-0604-2024Under Investigation by firmThe devices contain a dry natural rubber (latex) subcomponent, which are not labeled as containing dry natural rubber(latex).
Feb 13, 2017Class IIZ-1438-2017Nonconforming Material/ComponentThe Pump Relay Printed Circuit Board Assembly (PCBA) used in the CELL-DYN Ruby instrument may prematurely fail and lead to instrument stoppage
Mar 15, 2011Not classifiedZ-2019-2011PendingThe Nylon Washer has an outer diameter which is undersized resulting in the inability to generate patient results.
Apr 16, 2010Not classifiedZ-2352-2010Nonconforming Material/ComponentEpoxy holding the two parts of the waste reservoir together fails, potentially resulting in biohazardous fluid leaks.
Feb 12, 2009Not classifiedZ-1398-2009Device DesignBurn Risk-- when power is cycled to the instrument, there is a possibility that the Mixer Motor Assembly may reach 100 degrees Celsius (212 degrees Fahrenheit ). If the customer touches the motor, burns may occur.
Nov 17, 2008Not classifiedZ-1064-2009OtherCarryover failures in software revisions 1.0ML and 2.0ML result in elevated PLT background count.
Dec 22, 2006Not classifiedZ-0565-2007OtherResults for tests of RBC, MCV, RDW, MPV and PLT may be falsely elevated or falsely decreased when the Cell Dyn Diluent/Sheath reagent is used with Cell-Dyn 4000, Ruby and Sapphire systems.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 8.2 years on median.
  • 9 of the 13 ancestors have a recall of any class.
  • 1 other device also cites its predicate K972354.

How does its category compare?

All GKZ devices

GKZ Counter, Differential Cell: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GKZ

4in 2025

2007: 62008: 62009: 62010: 42011: 32012: 32013: 12014: 32015: 32016: 32017: 42018: 32019: 52020: 12022: 32023: 42024: 32025: 42026 (partial year): 4
2007high 6 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKZ

108in 2025

2007: 117 days median2008: 99 days median2009: 147 days median2010: 290 days median2011: 315 days median2012: 408 days median2014: 165 days median2015: 273 days median2016: 198 days median2017: 280 days median2018: 270 days median2019: 210 days median2022: 638 days median2023: 329 days median2024: 157 days median2025: 108 days median2026 (partial year): 254 days median
2007high 638 (2022) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GKZ

1in 2025

2007: 372008: 52009: 132010: 272011: 282012: 72013: 62015: 32016: 32017: 32018: 2, 2 Class I2019: 22020: 12022: 42023: 12025: 1
2007high 37 (2007) · low 0 (2014)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · GKZ

77in 2025

2007: 2682008: 9252009: 5592010: 8962011: 2,9052012: 2,9592013: 3,0702014: 3,1122015: 1,9722016: 3,3382017: 2292018: 4972019: 9082020: 3422021: 3912022: 1982023: 1552024: 1152025: 77
2007high 3,338 (2016) · low 77 (2025)2025

MAUDE reports naming product code GKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611737268
20086995925
2009614713559
2010429027896
20113315282,905
2012340872,959
20131—63,070
2014316503,112
2015327331,972
2016319833,338
201742803229
201832702 (2)497
201952102908
20201—1342
20210—0391
202236384198
202343291155
202431570115
20254108177
202642540—

What is it indicated for?

The CELL-DYN Ruby System is designed to analyze EDTA-anticoagulated blood and report the following hematological parameters: White Blood Cell Parameters WBC - White Blood Cell Concentration NEU - Neutrophil Absolute Concentration %N - Neutrophil Percentage of WBC LYM - Lymphocyte Absolute Concentration %L - Lymphocyte Percentage of WBC MONO - Monocyte Absolute Concentration %M - Monocyte Percentage of WBC EOS - Eosinophil Absolute Concentration %E -…

Read the full statement (140 words)

The CELL-DYN Ruby System is designed to analyze EDTA-anticoagulated blood and report the following hematological parameters:

White Blood Cell Parameters

WBC - White Blood Cell Concentration

NEU - Neutrophil Absolute Concentration

%N - Neutrophil Percentage of WBC

LYM - Lymphocyte Absolute Concentration

%L - Lymphocyte Percentage of WBC

MONO - Monocyte Absolute Concentration

%M - Monocyte Percentage of WBC

EOS - Eosinophil Absolute Concentration

%E - Eosinophil Percentage of WBC

BASO - Basophil Absolute Concentration

%B - Basophil Percentage of WBC

Red Blood Cell Parameters

RBC - Red Blood Cell Concentration

HCT - Hematocrit

MCV - Mean Cell Volume

RDW - Red Cell Distribution Width

%R - Reticulocyte Percent

RETC - Reticulocyte Absolute Concentration

Hemoglobin Parameters

HGB - Hemoglobin Concentration

MCH - Mean Cell Hemoglobin

MCHC - Mean Cell Hemoglobin Concentration

Platelet Parameters

PLT- Platelet Concentration

MPV- Mean Platelet Volume

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061667: Cell-Dyn Ruby System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K061667

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026