510(k) · Cleared
ClearedDimension Vista CRP Flex Reagent Cartridge, Protein 2 Calibrator, Control Low and Control High
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dade Behring, Inc. · DCN System, Test, C-Reactive Protein
Cleared on Sep 6, 2006 as substantially equivalent to K033908 (Dade Behring, Inc., 2004) and 2 other predicates after a 70-day review. Its family tree reaches back 2 generations to 1999.
- Decided
- Sep 6, 2006
- Review
- 70 days
- Class
- Class II
- Product code
- DCN
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 2 generations to K991385 (1999). 4 ancestors in all, the oldest K962373 (1996). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K991385 | Dade Behring N High Sensitivity CRP Assay | Dade Behring, Inc. | 1999 | — |
| −1 | K033908 | N High Sensitivity CRP | Dade Behring, Inc. | 2004 | — |
| 0 (this device) | K061825 | Dimension Vista CRP Flex Reagent Cartridge, Protein 2 Calibrator, Control Low… | Dade Behring, Inc. | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DCN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DCN device
- #1 K232624 CardioPhase® hsCRPscore 6.7 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K033908 | N High Sensitivity CRPSummary page 1…el: Immunology (82) and Clinical Chemistry (75) 3. Identification of the Legally Marketed Device: Dade Behring CardioPhasee hsCRP - K033908 Dade Behring N Rheumatology Standard SL - K964527 Dade Behring N/T Rheumatology Control SL - K962373 === Pag… | 2004 |
| * | K964527 | N Rheumatology Standard SLSummary page 1…(75) 3. Identification of the Legally Marketed Device: Dade Behring CardioPhasee hsCRP - K033908 Dade Behring N Rheumatology Standard SL - K964527 Dade Behring N/T Rheumatology Control SL - K962373 4. Device Description: Dimension Vista TM CR… | 1997 |
| * | K962373 | N/T Rheumatology Control SL/1 and SL/2Summary page 1…ce: Dade Behring CardioPhasee hsCRP - K033908 Dade Behring N Rheumatology Standard SL - K964527 Dade Behring N/T Rheumatology Control SL - K962373 4. Device Description: Dimension Vista TM CRP Flex® reagent cartridge Polystyrene particles coated w… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 4.2 years on median.
- None of the 4 ancestors has a recall.
- 10 other devices also cite its predicate K033908.
How does its category compare?
All DCN devicesDCN System, Test, C-Reactive Protein: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DCN
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · DCN
234in 2018
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DCN
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DCN
7in 2025
MAUDE reports naming product code DCN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 2 | — | 1 | 0 |
| 2009 | 3 | 111 | 0 | 0 |
| 2010 | 1 | — | 0 | 2 |
| 2011 | 0 | — | 0 | 5 |
| 2012 | 1 | — | 0 | 2 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 2 |
| 2015 | 0 | — | 0 | 2 |
| 2016 | 0 | — | 0 | 1 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 3 | 234 | 0 | 2 |
| 2019 | 0 | — | 1 | 8 |
| 2020 | 1 | — | 1 | 0 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 0 | — | 0 | 1 |
| 2023 | 2 | — | 0 | 3 |
| 2024 | 0 | — | 0 | 5 |
| 2025 | 0 | — | 0 | 7 |
| 2026 | 0 | — | 1 | — |
What is it indicated for?
The CRP method is an in vitro diagnostic test for the quantitative measurement of C-reactive protein (CRP) in human serum and heparinized plasma by means of particle enhanced immunonephelometry on the Dimension Vista TMSystem. In acute phase response, increased levels of a number of plasma proteins, including C-reactive protein, are observed. Measurement of CRP is useful for the detection and evaluation of infection, tissue injury, and inflammatory…
Read the full statement (124 words)
The CRP method is an in vitro diagnostic test for the quantitative measurement of C-reactive protein (CRP) in human serum and heparinized plasma by means of particle enhanced immunonephelometry on the Dimension Vista TMSystem. In acute phase response, increased levels of a number of plasma proteins, including C-reactive protein, are observed. Measurement of CRP is useful for the detection and evaluation of infection, tissue injury, and inflammatory disorders.
Protein 2 Calibrator is an in vitro diagnostic product for the calibration of the C-reactive protein (CRP) method on the Dimension VistaTM System.
Protein 2 Control L and H are for use as assayed intralaboratory quality controls for the assessment of precision and analytical bias in determination of C-reactive protein (CRP) on the Dimension VistaTM System.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061825 · printed Nov 5, 2026
Cite this page
510(k) Report. “K061825: Dimension Vista CRP Flex Reagent Cartridge, Protein 2 Calibrator, Control Low and Control High.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K061825
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026