510(k) Report

510(k) · Cleared

Cleared

Actim Prom and Controls

K061886510(k) TraditionalCleared Jan 25, 2007206-day reviewClass I21 CFR 862.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medix Biochemica · OAM Immunoassay, Insulin-Like Growth Factor Binding Protein-1

Cleared on Jan 25, 2007 as substantially equivalent to K030849 (N-Dia, Inc., 2004) after a 206-day review. Its family tree reaches back 1 generation to 2004. 2 later devices descend from it.

Decided
Jan 25, 2007
Review
206 days
Class
Class I
Product code
OAM
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K030849 (2004). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2011: 1 descendant clearedK030849 · Amnisure Fetal Membranes Rupture Test Model FMRT1 · N-Dia, Inc. · 2004 · recalled200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants K030849 · Amnisure Fetal Membranes Rupture Test Model FMRT1 · N-Dia, Inc. · 2004 · recalled0
  1. Root · 1 generation backK030849 Amnisure Fetal Membranes Rupture Test Model FMRT1N-Dia, Inc. · 2004 · Recalled
  2. This deviceK061886 Actim Prom and ControlsMedix Biochemica · 2007
  3. Descendant · cites it directly · 0 of its ownK123986 Actim PromAlere Scarborough, Inc. · 2014 · Recalled
  4. Descendant · cites it directly · 0 of its ownK110605 Rom PlusClinical Innovations, LLC · 2011 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K123986Actim PromAlere Scarborough, Inc. · 2014 · cites it directly0descendants
  • K110605Rom PlusClinical Innovations, LLC · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K030849Amnisure Fetal Membranes Rupture Test Model FMRT1N-Dia, Inc.20041
0 (this device)K061886Actim Prom and ControlsMedix Biochemica2007—
+1K123986Actim PromAlere Scarborough, Inc.20141
+1K110605Rom PlusClinical Innovations, LLC20111

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201410
FIG. 1 — Lineage of K061886, 2004–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OAM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030849Amnisure Fetal Membranes Rupture Test Model FMRT1
Summary page 1
…Quality Control Material (Assayed and Unassayed) 3. Predicate Device AmniSure ROM (Rupture Of [fetal] Membranes) Test N-Dia, Inc. K030849 4. Device Description The Actim PROM is a rapid test for detection of premature rupture of fetal membranes. The tes…
N-Dia, Inc.20041

Also cleared against K030849: 1 other device →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K123986Actim PromAlere Scarborough, Inc.20140
K110605Rom PlusClinical Innovations, LLC20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K123986 (Alere Scarborough, Inc., 2014) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K030849.

How does its category compare?

All OAM devices

OAM Immunoassay, Insulin-Like Growth Factor Binding Protein-1: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · OAM

1in 2014

2007: 12014: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OAM

Too few OAM 510(k)s in any year since 2007 to give a median.

Recalls per year · OAM

No recall names OAM since 2007.

Adverse event reports per year · OAM

3in 2021

2013: 12020: 32021: 3
2007high 3 (2020) · low 0 (2007)2025

MAUDE reports naming product code OAM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—01
20141—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—03
20210—03
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Actim PROM test is a visually interpreted, qualitative immunochromatographic rapid test for the detection of amniotic fluid in cervicovaginal secretions during pregnancy. Actim PROM test detects IGFBP-1, which is a major protein in amniotic fluid and a marker of the presence of amniotic fluid in a cervicovaginal sample. The test is intended for professional use to help diagnose the rupture of fetal membranes (ROM) in pregnant women at >34 weeks…

Read the full statement (121 words)

The Actim PROM test is a visually interpreted, qualitative immunochromatographic rapid test for the detection of amniotic fluid in cervicovaginal secretions during pregnancy. Actim PROM test detects IGFBP-1, which is a major protein in amniotic fluid and a marker of the presence of amniotic fluid in a cervicovaginal sample. The test is intended for professional use to help diagnose the rupture of fetal membranes (ROM) in pregnant women at >34 weeks gestation when patients report signs, symptoms or complaints suggestive of ROM or if such signs are otherwise observed.

The Actim PROM Controls are intended for use as external controls with the Actim PROM test. The controls may also be used to demonstrate negative results and weak and strong positive results.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061886: Actim Prom and Controls.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K061886

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026