# K062148: Depuy Pinnacle Altrx Acetabular Cup Liner

- Pathway: 510(k) (Traditional)
- Applicant: DePuy Orthopaedics, Inc.
- Decided: Oct 24, 2006 after 89 days
- Product code: LPH (Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented)
- Device class: 2
- Regulation: 21 CFR 888.3358
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 3 generations back to K930712 (1993). 9 ancestors in all.
106 later devices descend from it; 8 cite it directly.
0 of 116 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K033273: Depuy Pinnacle Acetabular Cup System, Esl Marathon Polyethylene Liners, and Depuy Ultima Unipolar Femoral Heads, DePuy Orthopaedics, Inc. (2004) Summary page 1.
- K000306: Pinnacle Acetabular System, DePuy Orthopaedics, Inc. (2000) Summary page 1.
- K052026: Lineage a-Class Poly Liner, Wrightmedicaltechnologyinc (2005) Summary page 1.

## Most influential descendants
- K073150: Apex-LNK Poly Acetabular Cup Liners (2008), 62 descendants of its own
- K100555: Apex-LNK Acetabular Insert, E, Apex-LNK Acetabular Insert, F, Apex-LNK (2010), 34 descendants of its own
- K100445: Klassic HD Hip System (2010), 25 descendants of its own
- K101575: Apex Modular Head, Size 28 ,32, 26 and 40 MM+10.5 Offset, Models 302810, 303210,303610,304010 (2010), 24 descendants of its own
- K103721: Mpact Acetabular System (2011), 21 descendants of its own

## Indications for use
The Pinnacle AltrX Acetabular Cup Liners are indicated for use in total hip replacement procedures. Total hip arthroplasty is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. Total hip replacement is indicated in the following conditions: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head or neck. 4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 5. Certain cases of ankylosis. The Pinnacle AltrX Acetabular Cup Liners are indicated for use with the Pinnacle Acetabular Cups in cementless applications.