510(k) · Cleared
Recalled · Class II · 2014Dimension Vista Cyclosporine (Csa) Flex Reagent Cartridge
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dade Behring, Inc. · MKW Cyclosporine
Cleared on Aug 21, 2006 as substantially equivalent to K023065 (Dade Behring, Inc., 2002) after a 19-day review. Its family tree reaches back 2 generations to 1989. It has been recalled 2 times.
- Decided
- Aug 21, 2006
- Review
- 19 days
- Class
- Class II
- Product code
- MKW
- Recalls
- 2
- Predicates
- 1
Its longest line of descent runs back 2 generations to P890025 (1989). No later device cites it as a predicate yet.
- Root · 2 generations backP890025 TD Cyclosporine and Metabolites Serum AssayAbbott Laboratories · 1989 · Recalled
- 1 generation backK023065 Cyclosporine (Csa) Flex Reagent CartridgeDade Behring, Inc. · 2002
- This deviceK062236 Dimension Vista Cyclosporine (Csa) Flex Reagent CartridgeDade Behring, Inc. · 2006
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MKW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023065 | Cyclosporine (Csa) Flex Reagent CartridgeSummary page 1…e: 862.1235 Cyclosporine Cyclosporine test system Product code: MKW Predicate Device: Dimension® Cyclosporine (CSA) Flex® reagent cartridge (K023065) Device Description: Dade Behring Dimension VistaTM Flex® reagent cartridges are prepackaged in-vitro diagnostic test methods (as… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Mar 19, 2014 | Class II | Z-1647-2014 | Device Design | A complaint was received of Dimension Vista¿ CSA and CSAE under-recovery of cyclosporine when patient samples are run from the Small Sample Container. The under-recovery that has been observed is 18 to 44%. In March 2014, Siemens recalled… |
| Dec 5, 2013 | Class II | Z-0818-2014 | Nonconforming Material/Component | Complaints were received regarding variability in recovery of QC and patient results with certain lots of the Dimension Vista CSA Flex reagent cartridges. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 2 companies; a new generation was cleared every 12.8 years on median.
- 1 of the 2 ancestors has a recall of any class.
How does its category compare?
All MKW devicesMKW Cyclosporine: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MKW
3in 2008
2026 to Oct 25, outlined.
Median 510(k) review, days · MKW
177in 2008
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MKW
1in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MKW
8in 2025
MAUDE reports naming product code MKW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 3 | 177 | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 1 | 2 |
| 2011 | 0 | — | 1 | 108 |
| 2012 | 0 | — | 0 | 36 |
| 2013 | 0 | — | 1 | 30 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 2 |
| 2016 | 0 | — | 0 | 4 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 3 |
| 2019 | 0 | — | 0 | 4 |
| 2020 | 0 | — | 0 | 2 |
| 2021 | 0 | — | 0 | 6 |
| 2022 | 0 | — | 0 | 7 |
| 2023 | 0 | — | 0 | 5 |
| 2024 | 0 | — | 0 | 6 |
| 2025 | 0 | — | 0 | 8 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Dimension VistaTM Cyclosporine (CSA) Flex® reagent cartridge is an in vitro
device intended to quantitatively determine cyclosporine concentrations in human whole
blood. Measurements of CSA are used as an aid in the management of heart, liver, and
kidney transplant patients receiving therapy with this drug.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K062236 · printed Nov 5, 2026
Cite this page
510(k) Report. “K062236: Dimension Vista Cyclosporine (Csa) Flex Reagent Cartridge.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K062236
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026