510(k) Report

510(k) · Cleared

Recalled · 2007

Zyoptix XP Epi Separator System

K062465510(k) TraditionalCleared Sep 6, 200613-day reviewClass I21 CFR 886.4370Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bausch & Lomb, Inc. · HNO Keratome, Ac-Powered

Cleared on Sep 6, 2006 as substantially equivalent to K040204 (Bausch & Lomb, Inc., 2004) after a 13-day review. Its family tree reaches back 4 generations to 1991. It has been recalled once.

Decided
Sep 6, 2006
Review
13 days
Class
Class I
Product code
HNO
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to K913697 (1991). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK913697 Automatic Corneal ShaperHansa Research & Development, Inc. · 1991
  2. 3 generations backK972808 Hansatome MicrokeratomeChiron Vision Corp. · 1997
  3. 2 generations backK021640 Hansatome Excellus MicrokeratomeBausch & Lomb, Inc. · 2002
  4. 1 generation backK040204 Zyoptix XP MicrokeratomeBausch & Lomb, Inc. · 2004 · Recalled
  5. This deviceK062465 Zyoptix XP Epi Separator SystemBausch & Lomb, Inc. · 2006
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K913697Automatic Corneal ShaperHansa Research & Development, Inc.1991—
−3K972808Hansatome MicrokeratomeChiron Vision Corp.1997—
−2K021640Hansatome Excellus MicrokeratomeBausch & Lomb, Inc.2002—
−1K040204Zyoptix XP MicrokeratomeBausch & Lomb, Inc.20044
0 (this device)K062465Zyoptix XP Epi Separator SystemBausch & Lomb, Inc.2006—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
FIG. 1 — Lineage of K062465, 1991–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HNO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040204Zyoptix XP Microkeratome
Summary page 1
…HNO Proprietary Name: Zyoptix XP Epi Separator System 3. Predicate Device Zyoptix XP Microkeratome K040204 4. Description of Device The Epi Separator System is designed exclusively for use with the Zyoptix XP Micro…
Bausch & Lomb, Inc.20044

Also cleared against K040204: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 8, 2007Not classifiedZ-1021-2007OtherReports have been received of stromal incursions after use of the product.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 4.7 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 1 other device also cites its predicate K040204.

How does its category compare?

All HNO devices

HNO Keratome, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HNO

1in 2018

2008: 12009: 12017: 12018: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HNO

Too few HNO 510(k)s in any year since 2007 to give a median.

Recalls per year · HNO

4in 2011

2007: 22008: 22011: 4
2007high 4 (2011) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HNO

7in 2024

2007: 322008: 312009: 852010: 842011: 902012: 1002013: 3532014: 4522015: 9662016: 1,3972017: 2,1122018: 2,2652019: 8162020: 4052021: 722022: 72023: 102024: 7
2007high 2,265 (2018) · low 0 (2025)2025

MAUDE reports naming product code HNO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—232
20081—231
20091—085
20100—084
20110—490
20120—0100
20130—0353
20140—0452
20150—0966
20160—01,397
20171—02,112
20181—02,265
20190—0816
20200—0405
20210—072
20220—07
20230—010
20240—07
20250—00
20260—0—

What is it indicated for?

The Zyoptix XP Epi Separator System is indicated for the partial or complete delamination of the corneal epithelium in preparation for subsequent surgical procedures on the denuded cornea.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K062465: Zyoptix XP Epi Separator System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062465

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026