510(k) Report

510(k) · Cleared

Cleared

Immunocard Stat! Ehec, Model 751630

K062546510(k) TraditionalCleared Feb 14, 2007168-day reviewClass I21 CFR 866.3255

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Meridian Bioscience, Inc. · GMZ Antigens, All Types, Escherichia Coli

Cleared on Feb 14, 2007 as substantially equivalent to K953362 (Meridian Diagnostics, Inc., 1995) after a 168-day review. Its family tree reaches back 1 generation to 1995. 3 later devices descend from it.

Decided
Feb 14, 2007
Review
168 days
Class
Class I
Product code
GMZ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K953362 (1995). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2012: 2 descendants cleared2023: 1 descendant clearedK953362 · Premier Ehec · Meridian Diagnostics, Inc. · 1995 · recalled1995200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant K953362 · Premier Ehec · Meridian Diagnostics, Inc. · 1995 · recalled0
  1. Root · 1 generation backK953362 Premier EhecMeridian Diagnostics, Inc. · 1995 · Recalled
  2. This deviceK062546 Immunocard Stat! Ehec, Model 751630Meridian Bioscience, Inc. · 2007
  3. Descendant · cites it directly · 1 of its ownK121364 Shiga Toxin Quik ChekTechlab Inc., Corporate Research Center · 2012
  4. Descendant · 2 generations on · 0 of its ownK222829 Curian® Shiga ToxinMeridian Bioscience, Inc. · 2023
  5. Descendant · cites it directly · 0 of its ownK121411 Shiga Toxin ChekTechlab Inc., Corporate Research Center · 2012

Most influential descendants

Showing 3 of 3 · See all
  • K121364Shiga Toxin Quik ChekTechlab Inc., Corporate Research Center · 2012 · cites it directly1descendant
  • K222829Curian® Shiga ToxinMeridian Bioscience, Inc. · 2023 · 2 generations on0descendants
  • K121411Shiga Toxin ChekTechlab Inc., Corporate Research Center · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K953362Premier EhecMeridian Diagnostics, Inc.19952
0 (this device)K062546Immunocard Stat! Ehec, Model 751630Meridian Bioscience, Inc.2007—
+1K121364Shiga Toxin Quik ChekTechlab Inc., Corporate Research Center2012—
+2K222829Curian® Shiga ToxinMeridian Bioscience, Inc.2023—
+1K121411Shiga Toxin ChekTechlab Inc., Corporate Research Center2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201220
202310
FIG. 1 — Lineage of K062546, 1995–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GMZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GMZ device

  1. #1 K222829 Curian® Shiga Toxinscore 5.8 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K953362Premier Ehec
Summary page 1
…'s clinical symptoms and other laboratory tests to aid in the diagnosis of diseases caused by enterohemorrhagic E. coi (EHEC) infections. PREDICATE DEVICE: Premier EHEC (K953362) BACKGROUND: Among the E. Go/i human pathogens, Shiga toxin-producing strains of E. coi have gained in importance in recent years…
Meridian Diagnostics, Inc.19952

Also cleared against K953362: 3 other devices →

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121364Shiga Toxin Quik ChekTechlab Inc., Corporate Research Center20121
K121411Shiga Toxin ChekTechlab Inc., Corporate Research Center20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K121364 (Techlab Inc., Corporate Research Center, 2012) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K953362.

How does its category compare?

All GMZ devices

GMZ Antigens, All Types, Escherichia Coli: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GMZ

1in 2023

2007: 12012: 22023: 1
2007high 2 (2012) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GMZ

Too few GMZ 510(k)s in any year since 2007 to give a median.

Recalls per year · GMZ

No recall names GMZ since 2007.

Adverse event reports per year · GMZ

1in 2017

2017: 1
2007high 1 (2017) · low 0 (2007)2025

MAUDE reports naming product code GMZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20110—00
20122—00
20130—00
20140—00
20150—00
20160—00
20170—01
20180—00
20190—00
20200—00
20210—00
20220—00
20231—00
20240—00
20250—00
20260—0—

What is it indicated for?

Immunoohromatographic rapid test for the qualitative detection of Shiga toxins 1 and 2 (also called Verotoxins) produced by E. coil in cultures derived from clinical stool specimens. ImmunoCard STATI EHEC is used in conjunction with the patients clinical symptoms and other laboratory tests to aid in the diagnosis of diseases caused by enterohemorrhagic E. co/i (EHEC) infections.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K062546: Immunocard Stat! Ehec, Model 751630.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062546

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026