Gladiator Bipolar System

K062693510(k) SpecialCleared Sep 29, 200618-day reviewClass II21 CFR 888.3390Recalls 6

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wrightmedicaltechnologyinc · KWY Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Cleared on Sep 29, 2006 after an 18-day review. The FDA summary names no predicate by number. 10 later devices descend from it. It has been recalled 6 times.

Decided
Sep 29, 2006
Review
18 days
Class
Class II
Product code
KWY
Recalls
6
Predicates
0

10 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2024: 2 descendants cleared2018: 3 descendants cleared2010: 1 descendant cleared2013: 1 descendant cleared2016: 1 descendant cleared2017: 1 descendant cleared2022: 1 descendant cleared20052010201520202025
  1. This deviceK062693 Gladiator Bipolar SystemWrightmedicaltechnologyinc · 2006
  2. Descendant · cites it directly · 5 of its ownK101670 United U2 Bipolar ImplantUnited Orthopedic Corp. · 2010 · Recalled
  3. Descendant · 2 generations on · 3 of its ownK152439 U2 Bipolar Implant and 22mm Femoral HeadUnited Orthopedic Corporation · 2016
  4. Descendant · cites it directly · 1 of its ownK173898 MicroPort Orthopedics Total Hip Systems MR LabelingMicroport Orthopedics Inc. (Mpo) · 2018
  5. Descendant · 3 generations on · 1 of its ownK162957 U2 Femoral HeadUnited Orthopedic Corporation · 2017
  6. Descendant · cites it directly · 0 of its ownK240046 Ethylene Oxide Sterilization Supplier Change for MPO HipsMicroport Orthopedics · 2024

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2010: 12013: 12016: 12017: 12018: 32022: 12024: 2
2010high 3 (2018) · low 0 (2011)2026

Most influential descendants

Showing 5 of 10 · See all
  • K101670United U2 Bipolar ImplantUnited Orthopedic Corp. · 2010 · cites it directly5descendants
  • K152439U2 Bipolar Implant and 22mm Femoral HeadUnited Orthopedic Corporation · 2016 · 2 generations on3descendants
  • K173898MicroPort Orthopedics Total Hip Systems MR LabelingMicroport Orthopedics Inc. (Mpo) · 2018 · cites it directly1descendant
  • K162957U2 Femoral HeadUnited Orthopedic Corporation · 2017 · 3 generations on1descendant
  • K240046Ethylene Oxide Sterilization Supplier Change for MPO HipsMicroport Orthopedics · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K062693Gladiator Bipolar SystemWrightmedicaltechnologyinc2006—
+1K101670United U2 Bipolar ImplantUnited Orthopedic Corp.20101
+2K152439U2 Bipolar Implant and 22mm Femoral HeadUnited Orthopedic Corporation2016—
+1K173898MicroPort Orthopedics Total Hip Systems MR LabelingMicroport Orthopedics Inc. (Mpo)2018—
+3K162957U2 Femoral HeadUnited Orthopedic Corporation2017—
+1K240046Ethylene Oxide Sterilization Supplier Change for MPO HipsMicroport Orthopedics2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201310
201610
201710
201830
202210
202420
FIG. 1 — Lineage of K062693, 2006–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWY device

  1. #1 K253357 b-ONE® Bipolar Headscore 11.2 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (10)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101670United U2 Bipolar ImplantUnited Orthopedic Corp.20105
K173898MicroPort Orthopedics Total Hip Systems MR LabelingMicroport Orthopedics Inc. (Mpo)20181
K240046Ethylene Oxide Sterilization Supplier Change for MPO HipsMicroport Orthopedics20240
K180130ELEOS™ Bipolar Acetabular SystemOnkos Surgical, Inc.20180

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 3, 2007Not classifiedZ-0572-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.
Jan 3, 2007Not classifiedZ-0569-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.
Jan 3, 2007Not classifiedZ-0570-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.
Jan 3, 2007Not classifiedZ-0571-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.
Jan 3, 2007Not classifiedZ-0567-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.
Jan 3, 2007Not classifiedZ-0568-2007OtherProduct specification failure which could result in improper locking of the cup onto the femoral head.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K101670 (United Orthopedic Corp., 2010) has gone furthest, with 5 descendants of its own.

How does its category compare?

All KWY devices

KWY Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWY

1in 2025

2008: 32009: 12010: 42011: 12012: 12013: 22014: 12015: 12016: 12017: 12018: 32019: 52020: 12022: 22023: 22025: 12026 (partial year): 1
2007high 5 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWY

126in 2019

2008: 123 days median2010: 187 days median2018: 219 days median2019: 126 days median
2007high 219 (2018) · low 123 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWY

2in 2025

2007: 252009: 242010: 12012: 12013: 22016: 32017: 22018: 12019: 12024: 12025: 2
2007high 25 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWY

180in 2025

2007: 3702008: 9002009: 9612010: 6882011: 7582012: 9782013: 1,1482014: 1,0552015: 1,2132016: 8772017: 8262018: 1,3802019: 1,5302020: 1,2592021: 2762022: 2082023: 1782024: 2092025: 180
2007high 1,530 (2019) · low 178 (2023)2025

MAUDE reports naming product code KWY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—25370
200831230900
20091—24961
201041871688
20111—0758
20121—1978
20132—21,148
20141—01,055
20151—01,213
20161—3877
20171—2826
2018321911,380
2019512611,530
20201—01,259
20210—0276
20222—0208
20232—0178
20240—1209
20251—2180
20261—0—

What is it indicated for?

The GLADIATOR TM Bipolar System is indicated for the following conditions:

1) pathological fractures of the femoral neck

2) non-union of femoral neck fractures

3) aseptic necrosis of the femoral head and neck

4) primary pathology in the young involving the femoral head but with a non-deformed acetabulum.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062693: Gladiator Bipolar System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062693

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026