Stryker Spine · MNI Orthosis, Spinal Pedicle Fixation

Cleared on Oct 11, 2006 as substantially equivalent to K032855 (Howmedica Osteonics, 2003) and 6 other predicates after a 30-day review. Its family tree reaches back 2 generations to 2000. 88 later devices descend from it. It has been recalled 2 times.

Decided
Oct 11, 2006
Review
30 days
Class
Class II
Product code
MNI
Recalls
2
Predicates
7

Its longest line of descent runs back 2 generations to K002858 (2000). 11 ancestors in all, the oldest K950697 (1995). 88 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 2 other ancestors2003: 1 other ancestor2001: 2 other ancestors1995: 2 other ancestors2002: 1 other ancestor1997: 1 other ancestor2007: 1 descendant cleared2013: 1 descendant cleared2010: 1 descendant cleared2011: 1 descendant cleared2017: 5 descendants cleared2015: 2 descendants cleared2014: 1 descendant cleared2023: 15 descendants cleared2018: 7 descendants cleared2020: 7 descendants cleared2024: 16 descendants cleared2021: 2 descendants cleared2019: 3 descendants cleared2022: 6 descendants cleared2016: 1 descendant cleared2026: 9 descendants cleared2025: 10 descendants clearedK002858 · Xia Spine System · Howmedica Osteonics Corp. · 2000K043473 · Modification to Xia Spinal System · Stryker Spine · 20051995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 6 other ancestors2 generations back: 3 other ancestors 1 generation forward: 3 descendants2 generations forward: 5 descendants3 generations forward: 21 descendants4 generations forward: 24 descendants5 generations forward: 16 descendants6 generations forward: 10 descendants7 generations forward: 6 descendants8 generations forward: 3 descendants K043473 · Modification to Xia Spinal System · Stryker Spine · 2005K002858 · Xia Spine System · Howmedica Osteonics Corp. · 20000+5
  1. Root · 2 generations backK002858 Xia Spine SystemHowmedica Osteonics Corp. · 2000
  2. 1 generation backK043473 Modification to Xia Spinal SystemStryker Spine · 2005
  3. This deviceK062698 Trio + Spinal SystemStryker Spine · 2006
  4. Descendant · cites it directly · 87 of its ownK070368 Trio Plate System, Trio Spinal Fixation System, Trio+ Spinal SystemStryker Corp. · 2007
  5. Descendant · cites it directly · 86 of its ownK100737 Modification to: Trio+Spinal Fixation SystemStryker Spine · 2010
  6. Descendant · 2 generations on · 85 of its ownK103292 Trio Trauma Spinal SystemStryker Corporation · 2011
  7. Descendant · cites it directly · 84 of its ownK133188 Mantis & Mantis Redux Spinal System, Radius Spinal System, Trio &…Stryker Spine · 2013
  8. Descendant · 2 generations on · 83 of its ownK142381 Xia 3 Spinal SystemStryker Corp. · 2014

Showing 5 of 88 descendants. See all descendants

Descendants cleared per year

2007: 12010: 12011: 12013: 12014: 12015: 22016: 12017: 52018: 72019: 32020: 72021: 22022: 62023: 152024: 162025: 102026: 9
2007high 16 (2024) · low 0 (2008)2026

Most influential descendants

Showing 5 of 88 · See all
  • K070368Trio Plate System, Trio Spinal Fixation System, Trio+ Spinal SystemStryker Corp. · 2007 · cites it directly87descendants
  • K100737Modification to: Trio+Spinal Fixation SystemStryker Spine · 2010 · cites it directly86descendants
  • K103292Trio Trauma Spinal SystemStryker Corporation · 2011 · 2 generations on85descendants
  • K133188Mantis & Mantis Redux Spinal System, Radius Spinal System, Trio & Trio+ Spinal Fixation…Stryker Spine · 2013 · cites it directly84descendants
  • K142381Xia 3 Spinal SystemStryker Corp. · 2014 · 2 generations on83descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002858Xia Spine SystemHowmedica Osteonics Corp.2000—
−1K043473Modification to Xia Spinal SystemStryker Spine2005—
0 (this device)K062698Trio + Spinal SystemStryker Spine2006—
+1K070368Trio Plate System, Trio Spinal Fixation System, Trio+ Spinal SystemStryker Corp.2007—
+1K100737Modification to: Trio+Spinal Fixation SystemStryker Spine2010—
+2K103292Trio Trauma Spinal SystemStryker Corporation2011—
+1K133188Mantis & Mantis Redux Spinal System, Radius Spinal System, Trio & Trio+ Spinal…Stryker Spine2013—
+2K142381Xia 3 Spinal SystemStryker Corp.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199520
199710
200120
200210
200310
200520

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
201010
201110
201310
201410
201520
201610
201750
201870
201930
202070
202120
202260
2023150
2024160
2025100
202690
FIG. 1 — Lineage of K062698, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MNI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (7)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032855Stryker Spine Maps System
Summary page 1
…System 87 MNI: Orthosis, Spinal, Pedicle Fixation Predicate Device Information: K032855 - Stryker Spine MAPS System (renamed Stryker Spine Trio® System)…
Howmedica Osteonics20031
*K052971Stryker Spine Trio Spinal Fixation System
Summary page 1
…2855 - Stryker Spine MAPS System (renamed Stryker Spine Trio® System) K052971 - Stryker Spine TRIO' Spinal System…
Stryker Spine20052
*K013823Xia Spinal System
Summary page 1
…K052971 - Stryker Spine TRIO' Spinal System K013823, K043473 - Stryker Spine Xia Spinal System…
Howmedica Osteonics Corp.2001—
*K043473Modification to Xia Spinal System
Summary page 1
…K052971 - Stryker Spine TRIO' Spinal System K013823, K043473 - Stryker Spine Xia Spinal System…
Stryker Spine2005—
*K012870Xia Stainless Steel System
Summary page 1
…K013823, K043473 - Stryker Spine Xia Spinal System K0 12870 - Stryker Spine Xia® Stainless Steel System…
Howmedica Osteonics Corp.2001—
*K050461Xia 4.5 Spinal System
Summary page 1
…K0 12870 - Stryker Spine Xia® Stainless Steel System K050461 -Stryker Spine Mio 4.5 Spinal System…
Stryker Spine2005—
*K951725Osteonics Spinal System
Summary page 1
…K050461 -Stryker Spine Mio 4.5 Spinal System K95 1725 - Stryker Spine Olsteonics Spinal System Line Extension to (he…
Osteonics Corp.1995—

Also cleared against K032855: 2 other devices →

What descends from it? (88)

See all 88

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K070368Trio Plate System, Trio Spinal Fixation System, Trio+ Spinal SystemStryker Corp.200787
K100737Modification to: Trio+Spinal Fixation SystemStryker Spine201086
K133188Mantis & Mantis Redux Spinal System, Radius Spinal System, Trio & Trio+ Spinal Fixation…Stryker Spine201384

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 25, 2012Class IIZ-2235-2012Labeling mix-upsThe front cover of Instructions For Use (IFU) #NOLI135B03Rev02 was improperly marked with a "Sterile" logo in the lower right corner. The products these IFUs were packed with are sold as "Non-Sterile" and require sterilization before use…
Jul 1, 2009Not classifiedZ-1886-2009OtherThe Trio 3.5MM Hex socket has been reported to break under high stresses.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 4.2 years on median.
  • 2 of the 11 ancestors have a recall of any class.
  • Of its descendants, K070368 (Stryker Corp., 2007) has gone furthest, with 87 descendants of its own.
  • 2 other devices also cite its predicate K032855.

How does its category compare?

All MNI devices

MNI Orthosis, Spinal Pedicle Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MNI

1in 2017

2007: 202008: 232009: 182010: 162011: 172012: 192013: 142014: 62015: 122016: 72017: 1
2007high 23 (2008) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNI

168in 2016

2007: 82 days median2008: 64 days median2009: 86 days median2010: 74 days median2011: 111 days median2012: 75 days median2013: 77 days median2014: 104 days median2015: 54 days median2016: 168 days median
2007high 168 (2016) · low 54 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MNI

1in 2018

2007: 262008: 82009: 32010: 12012: 12013: 42015: 12018: 1
2007high 26 (2007) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MNI

80in 2025

2007: 832008: 1082009: 1382010: 1262011: 1462012: 2002013: 8242014: 3012015: 2602016: 1172017: 2472018: 1342019: 1882020: 1152021: 2702022: 2142023: 1222024: 1142025: 80
2007high 824 (2013) · low 80 (2025)2025

MAUDE reports naming product code MNI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200720822683
200823648108
200918863138
201016741126
2011171110146
201219751200
201314774824
201461040301
201512541260
201671680117
20171—0247
20180—1134
20190—0188
20200—0115
20210—0270
20220—0214
20230—0122
20240—0114
20250—080
20260—0—

What is it indicated for?

The TRIO® and TRIO®+ Spinal Systems are pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocations, scoliosis, kyphosis, spinal tumor and…

Read the full statement (234 words)

The TRIO® and TRIO®+ Spinal Systems are pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocations, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).

The TRIO®and TRIO®+ Spinal Systems are also indicated for pedicle screw fixation for the treatment of severe spondylolisthesis (Grades 3 and 4) at the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the development of a solid fusion mass.

The TRIO® and TRIO®+ Spinal Systems are sacral/iliac screw fixation systems indicated for degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, kyphosis and/or lordosis), tumor, pseudoarthrosis and review of failed fusion attempts.

The TRIO® Spinal System is intended to be used in conjunction with the OSS Diapason Rods, Opus Spinal System Rods, and the Multi-Axis Cross Connectors.

The TRIO®+ Spinal System is intended to be used in conjunction with the OSS Diapason Rods, Opus Spinal System Rods, XiMa Pre-bent Rods, and the Multi-Axis Cross Connectors.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062698: Trio + Spinal System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K062698

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026