510(k) · Cleared
Recalled · Class II · 2017Sbi Lateral Rhead Implant
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Small Bone Innovations, Inc. · KWI Prosthesis, Elbow, Hemi-, Radial, Polymer
Cleared on Nov 13, 2006 after a 47-day review. The FDA summary names no predicate by number. It has been recalled 14 times.
- Decided
- Nov 13, 2006
- Review
- 47 days
- Class
- Class II
- Product code
- KWI
- Recalls
- 14
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWI device
- #1 K260624 Arthrex Radial Head Replacement Systemscore 12.1 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 24, 2017 | Class II | Z-2665-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2673-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2675-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2672-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2674-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2666-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2671-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2669-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2668-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2663-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2670-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2664-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Oct 24, 2017 | Class II | Z-2667-2018 | Under Investigation by firm | Revision rate identified as higher than other proximal radial head replacement devices based on literature review. Product may not perform at expected level post-surgery. |
| Sep 6, 2013 | Class II | Z-0098-2014 | Packaging change control | The recall was initiated due to an increased risk of implants breaching the sterile pouches inside the shrink-wrapped box. |
The 5 latest of 14 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KWI devicesKWI Prosthesis, Elbow, Hemi-, Radial, Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWI
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · KWI
Too few KWI 510(k)s in any year since 2007 to give a median.
Recalls per year · KWI
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWI
118in 2025
MAUDE reports naming product code KWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 15 |
| 2008 | 0 | — | 0 | 16 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 1 | — | 0 | 13 |
| 2011 | 0 | — | 0 | 10 |
| 2012 | 1 | — | 0 | 16 |
| 2013 | 1 | — | 1 | 31 |
| 2014 | 1 | — | 1 | 29 |
| 2015 | 0 | — | 0 | 103 |
| 2016 | 0 | — | 0 | 138 |
| 2017 | 1 | — | 1 | 360 |
| 2018 | 0 | — | 0 | 202 |
| 2019 | 1 | — | 0 | 214 |
| 2020 | 1 | — | 0 | 118 |
| 2021 | 1 | — | 0 | 44 |
| 2022 | 1 | — | 2 | 44 |
| 2023 | 1 | — | 0 | 77 |
| 2024 | 1 | — | 0 | 124 |
| 2025 | 0 | — | 0 | 118 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The SBi Lateral Assembly rHead is intended for replacement of the proximal end of the radius:
1. Replacement of the radial head for degenerative, or post-traumatic disabilities presenting pain, crepitation and decreased motion at the radiohumeral and or proximal radio-ulnar joint with:
a. Joint destruction or subluxation visible on x-ray
b. Resistance to conservative treatment
2. Primary replacement after fracture of the radial head
3. Symptomatic sequelae after radial head resection
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K062898 · printed Nov 4, 2026
Cite this page
510(k) Report. “K062898: Sbi Lateral Rhead Implant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062898
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026