510(k) Report

510(k) · Cleared

Cleared

Bard Balloon Dilation Kit with Trifunnel Gastrostomy Tube

K063118510(k) TraditionalCleared Feb 13, 2007125-day reviewClass II21 CFR 876.5980

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

C.R. Bard, Inc. · KNT Tubes, Gastrointestinal (And Accessories)

Cleared on Feb 13, 2007 as substantially equivalent to K915841 (C.R. Bard, Inc., 1993) after a 125-day review. Its family tree reaches back 1 generation to 1993. 3 later devices descend from it.

Decided
Feb 13, 2007
Review
125 days
Class
Class II
Product code
KNT
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K915841 (1993). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2010: 2 descendants cleared2009: 1 descendant clearedK915841 · Bard Gauderer Universal Percutaneous Endoscopic · C.R. Bard, Inc. · 1993 · recalled1990200020102020
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant K915841 · Bard Gauderer Universal Percutaneous Endoscopic · C.R. Bard, Inc. · 1993 · recalled0
  1. Root · 1 generation backK915841 Bard Gauderer Universal Percutaneous EndoscopicC.R. Bard, Inc. · 1993 · Recalled
  2. This deviceK063118 Bard Balloon Dilation Kit with Trifunnel Gastrostomy TubeC.R. Bard, Inc. · 2007
  3. Descendant · cites it directly · 2 of its ownK092049 Iyunni 3ID Tri-Funnel Gastrostomy Tube KitSainath Intellectual Properties, LLC · 2009
  4. Descendant · 2 generations on · 0 of its ownK102572 Iyunni 3ID Suprapubic Cystostomy Tube KitSainath Intellectual Properties, LLC · 2010
  5. Descendant · cites it directly · 0 of its ownK100173 Iyunni 3ID Tri-Funnel Feeding Tube KitSainath Intellectual Properties, LLC · 2010

Most influential descendants

Showing 3 of 3 · See all
  • K092049Iyunni 3ID Tri-Funnel Gastrostomy Tube KitSainath Intellectual Properties, LLC · 2009 · cites it directly2descendants
  • K102572Iyunni 3ID Suprapubic Cystostomy Tube KitSainath Intellectual Properties, LLC · 2010 · 2 generations on0descendants
  • K100173Iyunni 3ID Tri-Funnel Feeding Tube KitSainath Intellectual Properties, LLC · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K915841Bard Gauderer Universal Percutaneous EndoscopicC.R. Bard, Inc.199329
0 (this device)K063118Bard Balloon Dilation Kit with Trifunnel Gastrostomy TubeC.R. Bard, Inc.2007—
+1K092049Iyunni 3ID Tri-Funnel Gastrostomy Tube KitSainath Intellectual Properties, LLC2009—
+2K102572Iyunni 3ID Suprapubic Cystostomy Tube KitSainath Intellectual Properties, LLC2010—
+1K100173Iyunni 3ID Tri-Funnel Feeding Tube KitSainath Intellectual Properties, LLC2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201020
FIG. 1 — Lineage of K063118, 1993–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNT device

  1. #1 K261890 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®score 12.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K915841Bard Gauderer Universal Percutaneous Endoscopic
Summary page 1
…stinal Tube &Accessories CFR Reference: 21 CFR §876.5980, Class II Classification Panel: Gastroenterology/Urology Premarket Notification: K915841, clearance date 06/25/1993 5.4 Intended Use The "intended use" is the same for the subject and predicate kit. The kit…
C.R. Bard, Inc.199329

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092049Iyunni 3ID Tri-Funnel Gastrostomy Tube KitSainath Intellectual Properties, LLC20092
K100173Iyunni 3ID Tri-Funnel Feeding Tube KitSainath Intellectual Properties, LLC20100

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K092049 (Sainath Intellectual Properties, LLC, 2009) has gone furthest, with 2 descendants of its own.

How does its category compare?

All KNT devices

KNT Tubes, Gastrointestinal (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · KNT

4in 2025

2007: 102008: 102009: 112010: 122011: 72012: 122013: 72014: 162015: 102016: 62017: 92018: 72019: 102020: 52021: 62022: 72023: 52024: 92025: 42026 (partial year): 3
2007high 16 (2014) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNT

136in 2025

2007: 118 days median2008: 115 days median2009: 102 days median2010: 104 days median2011: 211 days median2012: 107 days median2013: 128 days median2014: 259 days median2015: 140 days median2016: 99 days median2017: 247 days median2018: 149 days median2019: 126 days median2020: 102 days median2021: 121 days median2022: 110 days median2023: 162 days median2024: 103 days median2025: 136 days median2026 (partial year): 105 days median
2007high 259 (2014) · low 99 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNT

13in 2025

2007: 12008: 822009: 92010: 32011: 22012: 12015: 12016: 32017: 42018: 22019: 22020: 12021: 22022: 1, 1 Class I2023: 22025: 132026 (partial year): 20
2007high 82 (2008) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · KNT

1,451in 2025

2007: 3002008: 8672009: 8182010: 5172011: 5312012: 5282013: 7472014: 1,0302015: 1,0482016: 1,2512017: 1,6722018: 1,9012019: 1,8382020: 1,6412021: 1,6552022: 1,6502023: 1,8632024: 1,3442025: 1,451
2007high 1,901 (2018) · low 300 (2007)2025

MAUDE reports naming product code KNT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007101181300
20081011582867
2009111029818
2010121043517
201172112531
2012121071528
201371280747
20141625901,030
20151014011,048
201669931,251
2017924741,672
2018714921,901
20191012621,838
2020510211,641
2021612121,655
202271101 (1)1,650
2023516221,863
2024910301,344
20254136131,451
2026310520—

What is it indicated for?

For initial percutaneous placement of a gastrostomy feeding and/or decompression device into a stoma created by tissue dilation.

Also for percutaneous replacement of a gastrostomy feeding and/or decompression device into an established stoma site.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063118: Bard Balloon Dilation Kit with Trifunnel Gastrostomy Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K063118

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026