510(k) · Cleared
ClearedNitinol Locking Incudo-Stapedial Joint, Angular Piston, Piston, Malleus Piston, Porp and Footplate Shoe
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Grace Medical, Inc. · ETB Prosthesis, Partial Ossicular Replacement
Cleared on Dec 6, 2006 as substantially equivalent to K033554 (Gyrus Ent LLC, 2003) and 6 other predicates after a 28-day review. Its family tree reaches back 3 generations to 2000. 4 later devices descend from it.
- Decided
- Dec 6, 2006
- Review
- 28 days
- Class
- Class II
- Product code
- ETB
- Recalls
- None
- Predicates
- 7
Its longest line of descent runs back 3 generations to K002221 (2000). 12 ancestors in all, the oldest K972492 (1997). 4 later devices descend from it, 1 citing it directly.
- Root · 3 generations backK002221 Kurkz K-Piston Titanium Stapedial Prosthesis, Model 1006 103-1006 170Heinz Kurz GmbH Medizintechnik · 2000
- 2 generations backK021479 Clip Piston Awengen, Model# 1006 805 - 1006 861Heinz Kurz GmbH Medizintechnik · 2002
- 1 generation backK042503 Kurz Clip Piston MVP, Model 1006 711-13/0.4 MM + 1006 761-63/0.6MMHeinz Kurz GmbH Medizintechnik · 2004
- This deviceK063374 Nitinol Locking Incudo-Stapedial Joint, Angular Piston, Piston…Grace Medical, Inc. · 2006
- Descendant · cites it directly · 3 of its ownK112616 Nitibond Stapes Prosthesis, Nitiplast Stapes ProsthesisHeinz Kurz GmbH Medizintechnik · 2013
- Descendant · 2 generations on · 2 of its ownK130512 Nitiflex Stapes Prosthesis, Detroit Piston, Skarzynski Piston…Heinz Kurz GmbH Medizintechnik · 2013
- Descendant · 3 generations on · 1 of its ownK241142 mAXIS Stapes Prosthesis, mLOOP Stapes Prosthesis, mZAM Stapes…MED-EL Elektromedizinische Geräte GmbH · 2025
- Descendant · 4 generations on · 0 of its ownK260720 mWING Stapes Prosthesis (0.4 x 3.50 mm) (58717); mWING Stapes…MED-EL Elektromedizinische Geräte GmbH · 2026
Most influential descendants
Showing 4 of 4 · See all- K112616Nitibond Stapes Prosthesis, Nitiplast Stapes ProsthesisHeinz Kurz GmbH Medizintechnik · 2013 · cites it directly3descendants
- K130512Nitiflex Stapes Prosthesis, Detroit Piston, Skarzynski Piston, Roberson Stapes ProsthesisHeinz Kurz GmbH Medizintechnik · 2013 · 2 generations on2descendants
- K241142mAXIS Stapes Prosthesis, mLOOP Stapes Prosthesis, mZAM Stapes Prosthesis and mFIX Stapes…MED-EL Elektromedizinische Geräte GmbH · 2025 · 3 generations on1descendant
- K260720mWING Stapes Prosthesis (0.4 x 3.50 mm) (58717); mWING Stapes Prosthesis (0.4 x 3.75 mm)…MED-EL Elektromedizinische Geräte GmbH · 2026 · 4 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K002221 | Kurkz K-Piston Titanium Stapedial Prosthesis, Model 1006 103-1006 170 | Heinz Kurz GmbH Medizintechnik | 2000 | — |
| −2 | K021479 | Clip Piston Awengen, Model# 1006 805 - 1006 861 | Heinz Kurz GmbH Medizintechnik | 2002 | — |
| −1 | K042503 | Kurz Clip Piston MVP, Model 1006 711-13/0.4 MM + 1006 761-63/0.6MM | Heinz Kurz GmbH Medizintechnik | 2004 | — |
| 0 (this device) | K063374 | Nitinol Locking Incudo-Stapedial Joint, Angular Piston, Piston, Malleus… | Grace Medical, Inc. | 2006 | — |
| +1 | K112616 | Nitibond Stapes Prosthesis, Nitiplast Stapes Prosthesis | Heinz Kurz GmbH Medizintechnik | 2013 | — |
| +2 | K130512 | Nitiflex Stapes Prosthesis, Detroit Piston, Skarzynski Piston, Roberson Stapes… | Heinz Kurz GmbH Medizintechnik | 2013 | — |
| +3 | K241142 | mAXIS Stapes Prosthesis, mLOOP Stapes Prosthesis, mZAM Stapes Prosthesis and… | MED-EL Elektromedizinische Geräte GmbH | 2025 | — |
| +4 | K260720 | mWING Stapes Prosthesis (0.4 x 3.50 mm) (58717); mWING Stapes Prosthesis (0.4… | MED-EL Elektromedizinische Geräte GmbH | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 3 | 0 |
| 1999 | 1 | 0 |
| 2000 | 3 | 0 |
| 2003 | 1 | 0 |
| 2006 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 2 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ETB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ETB device
- #1 K241142 mAXIS Stapes Prosthesis, mLOOP Stapes…score 13.2 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (7)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K033554 | Smart Offset Stapes Piston; Smart Isj ProsthesisSummary page 1…Date Prepared: November 8, 2006 Predicate Devices 1) SMart ISJ Prosthesis manufactured by Gyrus ENT LLC and cleared via 510(k) No. K033554. 2) SMart Piston manufactured by Gyrus ENT LLC and cleared via 510(k) No. K003214. 3) Angular Prosthesis (Plester… | 2003 |
| * | K003214 | Smith & Nephew PistonsSummary page 1…Prosthesis manufactured by Gyrus ENT LLC and cleared via 510(k) No. K033554. 2) SMart Piston manufactured by Gyrus ENT LLC and cleared via 510(k) No. K003214. 3) Angular Prosthesis (Plester) manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 510(k) No. K97… | 2000 |
| * | K972492 | Bell Prosthesis (Partial)Summary page 1…ENT LLC and cleared via 510(k) No. K003214. 3) Angular Prosthesis (Plester) manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 510(k) No. K972492. 4) CliP Piston MVP manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 5 10(k) No. K042503.… | 1997 |
| * | K042503 | Kurz Clip Piston MVP, Model 1006 711-13/0.4 MM + 1006 761-63/0.6MMSummary page 1…intechnik and cleared via 510(k) No. K972492. 4) CliP Piston MVP manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 5 10(k) No. K042503. 5) CliP Piston aWengen manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 510(k) No. K021479.… | 2004 |
| * | K021479 | Clip Piston Awengen, Model# 1006 805 - 1006 861Summary page 1…chnik and cleared via 5 10(k) No. K042503. 5) CliP Piston aWengen manufactured by Heinz Kurz GmbH Medizintechnik and cleared via 510(k) No. K021479. 6) Adjustable and Fixed-Length PORPs manufactured by Grace Medical, Inc. and cleared via 510(k) No. K061853.… | 2002 |
| * | K061853 | Grace Medical Adjustable and Fixed Length Partial & Total Ossicular Replacement ProsthesesSummary page 1…nik and cleared via 510(k) No. K021479. 6) Adjustable and Fixed-Length PORPs manufactured by Grace Medical, Inc. and cleared via 510(k) No. K061853. 7) Partial Ossicular Replacement Prosthesis manufactured by Grace Medical, Inc. and cleared via 510(k) K97281… | 2006 |
| * | K972815 | Partial/Total/Porous Polyethylene Ossicular ReplacementSummary page 1…and cleared via 510(k) No. K061853. 7) Partial Ossicular Replacement Prosthesis manufactured by Grace Medical, Inc. and cleared via 510(k) K972815. Intended Use - The Grace Medical Partial Ossicular Replacement Prostheses have the same primary intended use as the predicate d… | 1997 |
What descends from it? (4)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K112616 | Nitibond Stapes Prosthesis, Nitiplast Stapes Prosthesis | 2013 | 3 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 2.2 years on median.
- 1 of the 12 ancestors has a recall of any class.
- Of its descendants, K112616 (Heinz Kurz GmbH Medizintechnik, 2013) has gone furthest, with 3 descendants of its own.
- 1 other device also cites its predicate K033554.
How does its category compare?
All ETB devicesETB Prosthesis, Partial Ossicular Replacement: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · ETB
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ETB
Too few ETB 510(k)s in any year since 2007 to give a median.
Recalls per year · ETB
1so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · ETB
5in 2025
MAUDE reports naming product code ETB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 5 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 5 |
| 2011 | 0 | — | 0 | 3 |
| 2012 | 0 | — | 0 | 3 |
| 2013 | 2 | — | 0 | 3 |
| 2014 | 0 | — | 0 | 5 |
| 2015 | 0 | — | 0 | 2 |
| 2016 | 0 | — | 0 | 5 |
| 2017 | 0 | — | 0 | 3 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 6 |
| 2020 | 0 | — | 0 | 4 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 0 | — | 0 | 6 |
| 2023 | 0 | — | 0 | 1 |
| 2024 | 0 | — | 0 | 3 |
| 2025 | 2 | — | 0 | 5 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
An ossicular replacement prosthesis is a device intended to be implanted for the functional reconstruction of segments of the ossicular chain and facilitates the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. Indications for use include:
(a) Chronic middle ear disease,
(b) Otosclerosis,
(c) Congenital fixation of the stapes,
(d) Secondary surgical intervention to correct for a significant and persistent conductive hearing loss from prior otologic surgery, and
(e) Surgically correctible injury to the middle ear from trauma.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K063374 · printed Nov 6, 2026
Cite this page
510(k) Report. “K063374: Nitinol Locking Incudo-Stapedial Joint, Angular Piston, Piston, Malleus Piston, Porp and Footplate Shoe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K063374
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026