510(k) · Cleared
ClearedMA 55 Maestro
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Maico Diagnostics (Diagnostic Group, LLC) · EWO Audiometer
Cleared on Mar 29, 2007 after a 134-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Mar 29, 2007
- Review
- 134 days
- Class
- Class II
- Product code
- EWO
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EWO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new EWO device
- #1 K234095 OtoNova/OtoNova Proscore 9.3 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All EWO devicesEWO Audiometer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · EWO
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · EWO
173in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · EWO
4in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EWO
13in 2025
MAUDE reports naming product code EWO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 69 | 0 | 1 |
| 2008 | 1 | — | 1 | 1 |
| 2009 | 2 | — | 0 | 1 |
| 2010 | 2 | — | 0 | 4 |
| 2011 | 3 | 151 | 0 | 2 |
| 2012 | 4 | 137 | 0 | 0 |
| 2013 | 2 | — | 0 | 0 |
| 2014 | 1 | — | 0 | 0 |
| 2015 | 4 | 173 | 0 | 1 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 0 |
| 2018 | 2 | — | 0 | 0 |
| 2019 | 1 | — | 0 | 6 |
| 2020 | 0 | — | 0 | 7 |
| 2021 | 0 | — | 0 | 3 |
| 2022 | 1 | — | 0 | 6 |
| 2023 | 1 | — | 4 | 3 |
| 2024 | 2 | — | 0 | 2 |
| 2025 | 0 | — | 0 | 13 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The MA55 system is intended to be used for the detection and diagnosis of suspected hearing loss.
(Other module functions may be added to this platform in the future, each module will be re-applied for at that time.)
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K063452 · printed Nov 6, 2026
Cite this page
510(k) Report. “K063452: MA 55 Maestro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K063452
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026