510(k) Report

510(k) · Cleared

Cleared

Modification to Proxis System, Model Eps 101

K063638510(k) TraditionalCleared May 11, 2007155-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

St Jude Medical · DQY Catheter, Percutaneous

Cleared on May 11, 2007 as substantially equivalent to K042117 (Velocimed, Inc., 2005) and 1 other predicate after a 155-day review. Its family tree reaches back 4 generations to 1991. 1 later device descends from it.

Decided
May 11, 2007
Review
155 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K913517 (1991). 14 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2003: 2 other ancestors2002: 2 other ancestors2001: 2 other ancestors1999: 1 other ancestor1995: 1 other ancestor1993: 1 other ancestor2008: 1 descendant clearedK913517 · Isolate Infusion Cathetr System · Lake Region Mfg., Inc. · 1991K023548 · Proxis Flow-Control Device, Models Eps 101, IC 101 · Velocimed · 2003K042117 · Proxis System, Model Eps 101 · Velocimed, Inc. · 2005K060651 · Proxis System, Model EPS101 · St Jude Medical · 20061990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 4 other ancestors3 generations back: 6 other ancestors 1 generation forward: 1 descendant K060651 · Proxis System, Model EPS101 · St Jude Medical · 2006K042117 · Proxis System, Model Eps 101 · Velocimed, Inc. · 2005K023548 · Proxis Flow-Control Device, Models Eps 101, IC 101 · Velocimed · 2003K913517 · Isolate Infusion Cathetr System · Lake Region Mfg., Inc. · 19910
  1. Root · 4 generations backK913517 Isolate Infusion Cathetr SystemLake Region Mfg., Inc. · 1991
  2. 3 generations backK023548 Proxis Flow-Control Device, Models Eps 101, IC 101Velocimed · 2003
  3. 2 generations backK042117 Proxis System, Model Eps 101Velocimed, Inc. · 2005
  4. 1 generation backK060651 Proxis System, Model EPS101St Jude Medical · 2006
  5. This deviceK063638 Modification to Proxis System, Model Eps 101St Jude Medical · 2007
  6. Descendant · cites it directly · 0 of its ownK073700 6F Proxis SystemSt. Jude Medical, Inc. · 2008

Most influential descendants

Showing 1 of 1 · See all
  • K0737006F Proxis SystemSt. Jude Medical, Inc. · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K913517Isolate Infusion Cathetr SystemLake Region Mfg., Inc.1991—
−3K023548Proxis Flow-Control Device, Models Eps 101, IC 101Velocimed2003—
−2K042117Proxis System, Model Eps 101Velocimed, Inc.2005—
−1K060651Proxis System, Model EPS101St Jude Medical2006—
0 (this device)K063638Modification to Proxis System, Model Eps 101St Jude Medical2007—
+1K0737006F Proxis SystemSt. Jude Medical, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199510
199910
200120
200220
200320
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
FIG. 1 — Lineage of K063638, 1991–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042117Proxis System, Model Eps 101
Summary page 2
…Flow Control System device covered by this submission is identical in function, mechanism of action and intended use as the market cleared rapid-exchange Proxis System (K042117). In addition, the technological characteristics and ability to control fluid flow are identical to the over-the-wire Proxis Syst…
Velocimed, Inc.2005—
*K060651Proxis System, Model EPS101
Summary page 2
…mbolic protection. Predicate Device Comparison / Technological Characteristics The Proxis Flow Control System, a modification of the current over-the-wire Proxis System (K060651), was created by decreasing the diameter of the catheter and sealing balloon. The Proxis Flow Control System device covered by th…
St Jude Medical2006—

Also cleared against K042117: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K0737006F Proxis SystemSt. Jude Medical, Inc.20080

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 1.7 years on median.
  • 1 of the 14 ancestors has a recall of any class.
  • Of its descendants, K073700 (St. Jude Medical, Inc., 2008) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K042117.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The Proxis Flow Control system controls the flow of fluids in the coronary and peripheral vasculature. This is achieved by temporary vessel occlusion to hold a column of fluid in the vessel stagnant. The stagnant column can be used to aid in the visualization of the lesion or be used as a means of local and temporary delivery of therapeutic solution(s). The safety and efficacy of this device as an embolic protection system has not been established. The Proxis Flow Control System is not indicated for use for embolic protection.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063638: Modification to Proxis System, Model Eps 101.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K063638

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026