510(k) Report

510(k) · Cleared

Cleared

Resonance Metallic Ureteral Stent

K063742510(k) TraditionalCleared May 8, 2007141-day reviewClass II21 CFR 876.4620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook Ireland, Ltd. · FAD Stent, Ureteral

Cleared on May 8, 2007 as substantially equivalent to K033210 (Bioteque Corp., 2004) and 1 other predicate after a 141-day review. Its family tree reaches back 2 generations to 1991.

Decided
May 8, 2007
Review
141 days
Class
Class II
Product code
FAD
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K905289 (1991). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2004: 1 other ancestor1999: 1 other ancestorK905289 · Surgitek (R) Lubri-Flex (TM) Ureteral Stent · Medical Engineering Corp. · 1991K961446 · AQ Hydrophilic Stent · Cook Urological, Inc. · 1996 · recalled1990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor K961446 · AQ Hydrophilic Stent · Cook Urological, Inc. · 1996 · recalledK905289 · Surgitek (R) Lubri-Flex (TM) Ureteral Stent · Medical Engineering Corp. · 19910
  1. Root · 2 generations backK905289 Surgitek (R) Lubri-Flex (TM) Ureteral StentMedical Engineering Corp. · 1991
  2. 1 generation backK961446 AQ Hydrophilic StentCook Urological, Inc. · 1996 · Recalled
  3. This deviceK063742 Resonance Metallic Ureteral StentCook Ireland, Ltd. · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K905289Surgitek (R) Lubri-Flex (TM) Ureteral StentMedical Engineering Corp.1991—
−1K961446AQ Hydrophilic StentCook Urological, Inc.199618
0 (this device)K063742Resonance Metallic Ureteral StentCook Ireland, Ltd.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
200410
FIG. 1 — Lineage of K063742, 1991–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FAD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FAD device

  1. #1 K251890 Disposable Ureteral Stentsscore 12.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033210Bioteq Double Pigtail Ureteral Stent Set
Summary page 1
…Legally Marketed Devices: Bioteq Double Pigtail Ureteral Stent set (K033210) Cook Endo-SofPM Double Pigtail Stent…
Bioteque Corp.2004—
*K961446AQ Hydrophilic Stent
Summary page 1
…10) Cook Endo-SofPM Double Pigtail Stent (K961446) Description of the Device: The Resonance Tm Metallic ureteral stent is a…
Cook Urological, Inc.199618

Also cleared against K033210: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 10.9 years on median.
  • 1 of the 4 ancestors has a recall of any class.
  • 1 other device also cites its predicate K033210.

How does its category compare?

All FAD devices

FAD Stent, Ureteral: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · FAD

4in 2025

2007: 12008: 12010: 12014: 12016: 42017: 82018: 92019: 52020: 12021: 22022: 52024: 12025: 42026 (partial year): 1
2007high 9 (2018) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FAD

186in 2025

2016: 143 days median2017: 266 days median2018: 258 days median2019: 263 days median2022: 143 days median2025: 186 days median
2007high 266 (2017) · low 143 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FAD

4in 2025

2007: 12008: 222009: 22010: 12016: 42019: 62020: 22021: 12022: 92025: 4
2007high 22 (2008) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FAD

634in 2025

2007: 432008: 762009: 1232010: 782011: 952012: 1312013: 822014: 782015: 1302016: 1822017: 2652018: 2772019: 2612020: 3522021: 5312022: 5592023: 6912024: 6032025: 634
2007high 691 (2023) · low 43 (2007)2025

MAUDE reports naming product code FAD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—143
20081—2276
20090—2123
20101—178
20110—095
20120—0131
20130—082
20141—078
20150—0130
201641434182
201782660265
201892580277
201952636261
20201—2352
20212—1531
202251439559
20230—0691
20241—0603
202541864634
20261—0—

What is it indicated for?

Used for temporary stenting of the ureter in adult patients with extrinsic ureteral obstruction.

Intended for one-time use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063742: Resonance Metallic Ureteral Stent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K063742

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026