NMR Profiler and NMR Lipoprofile Assay, Controls

K063841510(k) TraditionalCleared Jul 23, 2008575-day reviewClass I21 CFR 862.1475

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Liposcience · MRR System, Test, Low Density, Lipoprotein

Cleared on Jul 23, 2008 as substantially equivalent to K020724 (Dade Behring, Inc., 2002) and 2 other predicates after a 575-day review. Its family tree reaches back 2 generations to 1997. 4 later devices descend from it.

Decided
Jul 23, 2008
Review
575 days
Class
Class I
Product code
MRR
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K971573 (1997). 4 ancestors in all, the oldest K971162 (1997). 4 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 2 other ancestors2011: 1 descendant cleared2023: 1 descendant cleared2012: 1 descendant cleared2014: 1 descendant clearedK971573 · N-Geneous LDL Cholesterol Reagent, N-Geneous LDL Cholesterol Calibrator, Genzyme LDL Cholesterol Control Set · Genzyme Corp. · 1997K020724 · Dimension Automated LDL Cholesterol Flex Reagentcartridge Method, Model DF131 · Dade Behring, Inc. · 20021995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant K020724 · Dimension Automated LDL Cholesterol Flex Reagentcartridge Method, Model DF131 · Dade Behring, Inc. · 2002K971573 · N-Geneous LDL Cholesterol Reagent, N-Geneous LDL Cholesterol Calibrator, Genzyme LDL Cholesterol Control Set · Genzyme Corp. · 19970
  1. Root · 2 generations backK971573 N-Geneous LDL Cholesterol Reagent, N-Geneous LDL Cholesterol…Genzyme Corp. · 1997
  2. 1 generation backK020724 Dimension Automated LDL Cholesterol Flex Reagentcartridge Method…Dade Behring, Inc. · 2002
  3. This deviceK063841 NMR Profiler and NMR Lipoprofile Assay, ControlsLiposcience · 2008
  4. Descendant · cites it directly · 2 of its ownK111516 NMR Lipoprofile (R) Test and NMR ProfilerLiposcience, Inc. · 2011
  5. Descendant · 2 generations on · 1 of its ownK113830 Vantera Clinical AnalyzerLiposcience · 2012
  6. Descendant · cites it directly · 0 of its ownK210801 AXINON® LDL-p Test SystemNumares AG · 2023
  7. Descendant · 3 generations on · 0 of its ownK133849 Vantera Clinical AnalyzerLiposcience · 2014

Most influential descendants

Showing 4 of 4 · See all
  • K111516NMR Lipoprofile (R) Test and NMR ProfilerLiposcience, Inc. · 2011 · cites it directly2descendants
  • K113830Vantera Clinical AnalyzerLiposcience · 2012 · 2 generations on1descendant
  • K210801AXINON® LDL-p Test SystemNumares AG · 2023 · cites it directly0descendants
  • K133849Vantera Clinical AnalyzerLiposcience · 2014 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K971573N-Geneous LDL Cholesterol Reagent, N-Geneous LDL Cholesterol Calibrator…Genzyme Corp.1997—
−1K020724Dimension Automated LDL Cholesterol Flex Reagentcartridge Method, Model DF131Dade Behring, Inc.2002—
0 (this device)K063841NMR Profiler and NMR Lipoprofile Assay, ControlsLiposcience2008—
+1K111516NMR Lipoprofile (R) Test and NMR ProfilerLiposcience, Inc.2011—
+2K113830Vantera Clinical AnalyzerLiposcience2012—
+1K210801AXINON® LDL-p Test SystemNumares AG2023—
+3K133849Vantera Clinical AnalyzerLiposcience2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199720

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
201410
202310
FIG. 1 — Lineage of K063841, 1997–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MRR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MRR device

  1. #1 K241800 Atellica® CH HDL Cholesterol (HDLC)& Atellica®…score 8.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020724Dimension Automated LDL Cholesterol Flex Reagentcartridge Method, Model DF131
Summary page 2
…CFR 862.1150, JIT) Predicate Device(s) Device Name: Dimension Automated LDL Cholesterol Flex Reagent Manufacturer: Dade Behring, Inc. 510(k) Number: K020724 Device Name: Triglycerides Reagent Manufacturer: Carolina Liquid Chemistries 510(k) Number. K971324…
Dade Behring, Inc.2002—
*K971324Triglycerides, TG, or Trig
Summary page 2
…turer: Dade Behring, Inc. 510(k) Number: K020724 Device Name: Triglycerides Reagent Manufacturer: Carolina Liquid Chemistries 510(k) Number. K971324 Device Name: Liquid N-geneous HDL Cholesterol Kit Manufacturer: Genzyme Corporation 510(k) Number: K971162…
Carolina Liquid Chemistries Corp.1997—
*K971162Liquid N-Geneous HDL Cholesterol Kit/Calibrator
Summary page 2
…Liquid Chemistries 510(k) Number. K971324 Device Name: Liquid N-geneous HDL Cholesterol Kit Manufacturer: Genzyme Corporation 510(k) Number: K971162 Intended Use / Indications for Use The NMR LipoProfile®-2 test, used with the NMR Profiler, an automated NMR spectrometer, meas…
Genzyme Corp.1997—

Also cleared against K020724: 2 other devices →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111516NMR Lipoprofile (R) Test and NMR ProfilerLiposcience, Inc.20112
K210801AXINON® LDL-p Test SystemNumares AG20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 6.2 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K111516 (Liposcience, Inc., 2011) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K020724.

How does its category compare?

All MRR devices

MRR System, Test, Low Density, Lipoprotein: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · MRR

1in 2024

2008: 12009: 22017: 12023: 12024: 1
2007high 2 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MRR

Too few MRR 510(k)s in any year since 2007 to give a median.

Recalls per year · MRR

1in 2025

2008: 22018: 12025: 1
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MRR

1in 2024

2011: 32017: 32018: 22020: 12021: 12022: 12023: 12024: 1
2007high 3 (2011) · low 0 (2007)2025

MAUDE reports naming product code MRR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—20
20092—00
20100—00
20110—03
20120—00
20130—00
20140—00
20150—00
20160—00
20171—03
20180—12
20190—00
20200—01
20210—01
20220—01
20231—01
20241—01
20250—10
20260—0—

What is it indicated for?

The NMR LipoProfile®-2 test, used with the NMR Profiler, an automated NMR spectrometer, measures lipoprotein particles to quantify LDL particle number (LDL-P), HDL cholesterol (HDL-C), and triglycerides in serum and plasma using nuclear magnetic resonance (NMR) spectroscopy. LDL-P and these NMR-derived concentrations of triglycerides and HDL-C are used in conjunction with other lipid measurements and clinical evaluation to aid in the management of lipoprotein disorders associated with cardiovascular disease. The test is performed and provided as a service by Liposcience Laboratory.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063841: NMR Profiler and NMR Lipoprofile Assay, Controls.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K063841

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026