510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Power Injectable Implantable Infusion Port with Silicone Lumen (Attachable and Pre-Attached)

K070003510(k) TraditionalCleared May 15, 2007132-day reviewClass II21 CFR 880.5965Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medcomp · LJT Port & Catheter, Implanted, Subcutaneous, Intravascular

Cleared on May 15, 2007 as substantially equivalent to K864349 (C.R. Bard, Inc., 1987) and 1 other predicate after a 132-day review. Its family tree reaches back 7 generations to 2000. 20 later devices descend from it. It has been recalled 3 times.

Decided
May 15, 2007
Review
132 days
Class
Class II
Product code
LJT
Recalls
3
Predicates
2

Its longest line of descent runs back 7 generations to K001901 (2000). 21 ancestors in all, the oldest K863606 (1986). 20 later devices descend from it, 8 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1987: 2 other ancestors2005: 2 other ancestors2004: 2 other ancestors2001: 1 other ancestor2000: 1 other ancestor1986: 1 other ancestor1991: 1 other ancestor1989: 4 other ancestors2013: 5 descendants cleared2009: 1 descendant cleared2011: 4 descendants cleared2007: 2 descendants cleared2012: 2 descendants cleared2008: 1 descendant cleared2019: 1 descendant cleared2020: 2 descendants cleared2015: 1 descendant cleared2023: 1 descendant clearedK001901 · Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline Catheter, Model 3134135 · C.R. Bard, Inc. · 2000 · recalledK012902 · Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath Dual Lumen Picc Catheter, Model 3246100 · C.R. Bard, Inc. · 2001K031129 · Poly Per-Q-Cath Picc Catheters; Poly Radpicc · C.R. Bard, Inc. · 2003K034019 · Poly Per-Q-Cath Picc Catheters · C.R. Bard, Inc. · 2004 · recalledK050931 · 6 FR DL Powerpicc Catheter · C.R. Bard, Inc. · 2005K051672 · Powerpicc · Bard Access Systems, Inc. · 2005 · recalledK060812 · Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-Multiple · C.R. Bard, Inc. · 2006 · recalled1990200020102020
  1. Root · 7 generations backK001901 Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath…C.R. Bard, Inc. · 2000 · Recalled
  2. 6 generations backK012902 Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly…C.R. Bard, Inc. · 2001
  3. 5 generations backK031129 Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc. · 2003
  4. 4 generations backK034019 Poly Per-Q-Cath Picc CathetersC.R. Bard, Inc. · 2004 · Recalled
  5. 3 generations backK050931 6 FR DL Powerpicc CatheterC.R. Bard, Inc. · 2005
  6. 2 generations backK051672 PowerpiccBard Access Systems, Inc. · 2005 · Recalled
  7. 1 generation backK060812 Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex…C.R. Bard, Inc. · 2006 · Recalled
  8. This deviceK070003 Power Injectable Implantable Infusion Port with Silicone Lumen…Medcomp · 2007
  9. Descendant · cites it directly · 5 of its ownK091099 C-Port - HP Power Injectable PortPhs Medical GmbH · 2009
  10. Descendant · cites it directly · 5 of its ownK072481 Jet Port Plus HP Catheter SystemPfm Medical, Inc. · 2008
  11. Descendant · cites it directly · 5 of its ownK071993 T-Port HP Infusion PortPfm Medical, Inc. · 2007
  12. Descendant · 2 generations on · 4 of its ownK073210 Modification to: T-Port HP Infusion PortPfm Medical, Inc. · 2007
  13. Descendant · 2 generations on · 3 of its ownK122767 Nmi PortNavilyst Medical, Inc. · 2013 · Recalled

Showing 5 of 20 descendants. See all descendants

Descendants cleared per year

2007: 22008: 12009: 12011: 42012: 22013: 52015: 12019: 12020: 22023: 1
2007high 5 (2013) · low 0 (2010)2026

Most influential descendants

Showing 5 of 20 · See all
  • K091099C-Port - HP Power Injectable PortPhs Medical GmbH · 2009 · cites it directly5descendants
  • K072481Jet Port Plus HP Catheter SystemPfm Medical, Inc. · 2008 · cites it directly5descendants
  • K071993T-Port HP Infusion PortPfm Medical, Inc. · 2007 · cites it directly5descendants
  • K073210Modification to: T-Port HP Infusion PortPfm Medical, Inc. · 2007 · 2 generations on4descendants
  • K122767Nmi PortNavilyst Medical, Inc. · 2013 · 2 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K001901Poly Per-Q-Cath Picc Catheter,Model 3236100 and Poly Per-Q-Cath Midline…C.R. Bard, Inc.20002
−6K012902Poly Per-Q-Cath Single Lumen Picc Catheter, Model 3143100; Poly Per-Q-Cath…C.R. Bard, Inc.2001—
−5K031129Poly Per-Q-Cath Picc Catheters; Poly RadpiccC.R. Bard, Inc.2003—
−4K034019Poly Per-Q-Cath Picc CathetersC.R. Bard, Inc.20041
−3K0509316 FR DL Powerpicc CatheterC.R. Bard, Inc.2005—
−2K051672PowerpiccBard Access Systems, Inc.20051
−1K060812Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-MultipleC.R. Bard, Inc.20061
0 (this device)K070003Power Injectable Implantable Infusion Port with Silicone Lumen (Attachable and…Medcomp2007—
+1K091099C-Port - HP Power Injectable PortPhs Medical GmbH2009—
+1K072481Jet Port Plus HP Catheter SystemPfm Medical, Inc.2008—
+1K071993T-Port HP Infusion PortPfm Medical, Inc.2007—
+2K073210Modification to: T-Port HP Infusion PortPfm Medical, Inc.2007—
+2K122767Nmi PortNavilyst Medical, Inc.20136

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198720
198940
199110
200010
200110
200420
200520

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200720
200810
200910
201140
201220
201350
201510
201910
202020
202310
FIG. 1 — Lineage of K070003, 2000–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LJT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LJT device

  1. #1 K251253 PowerPort™ isp Implantable Port; PowerPort™…score 14.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K864349Mediport II Single Lum/Port Implant Vasc Acs Port
Summary page 1
…C.F.R. Section: 880.5965 Device Classification: II C. Predicate Devices: K864349 Mediport IISingle Lum/Port Vascular Access Port (M.R.I)., Bard Access…
C.R. Bard, Inc.1987—
*K060812Powerport (TM)Implanted Titanium Port W/8 FR. Chronoflex Catheter-Multiple
Summary page 1
…Vascular Access Port (M.R.I)., Bard Access Systems K060812, PowerPort Implanted Titanium Port with 8Fr. ChronoFlex& Catheter., Bard…
C.R. Bard, Inc.20061

What descends from it? (20)

See all 20

8 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091099C-Port - HP Power Injectable PortPhs Medical GmbH20095
K072481Jet Port Plus HP Catheter SystemPfm Medical, Inc.20085
K071993T-Port HP Infusion PortPfm Medical, Inc.20075
K123292T3Medcomp20132
K111101Norport CT-PC, Lucent Non-Coring Needel Infusion SetNorfolk Medical20112
K110424Dignity Mini Port- Attachable; Dignity Mini Port- Pre Attached; Dignity Low Profile…Medcomp ( Medical Components)20111
K132177Medcomp Gen Iii Power Injectable PortMedcomp ( Medical Components)20130
K120281Dignity Power Injectable Titanium PortMedical Components, Inc.20120

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 12, 2012Not classifiedZ-1626-2012Employee error50 trays of Dignity Low Profile CT Port were labeled as Dignity Mid-Sized CT Port.
Apr 2, 2012Class IIZ-1868-2012Packaging process controlProduct was packaged with the incorrect port and does not match the label. The kit is labeled as an 8F Low Profile Pro-Fuse CT Port. The kit contains an 8F Midsize Dignity CT Port.
Jul 2, 2010Not classifiedZ-2235-2010Employee errorRecalled product was packaged with the incorrect port and does not match the label. The kit is labeled as a 6.6F "Dignity" Low Profile CT Port. The kit contains a 6.6F "Pro-Fuse" Low Profile CT Port.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 10 months on median.
  • 11 of the 21 ancestors have a recall of any class.
  • Of its descendants, K091099 (Phs Medical GmbH, 2009) has gone furthest, with 5 descendants of its own.

How does its category compare?

All LJT devices

LJT Port & Catheter, Implanted, Subcutaneous, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · LJT

2in 2025

2007: 112008: 72009: 22010: 22011: 52012: 22013: 72014: 22015: 42016: 32019: 12020: 12023: 12024: 12025: 22026 (partial year): 1
2007high 11 (2007) · low 0 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LJT

182in 2016

2007: 85 days median2008: 119 days median2011: 144 days median2013: 150 days median2015: 164 days median2016: 182 days median
2007high 182 (2016) · low 85 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LJT

1in 2022

2007: 12008: 22009: 22010: 192011: 12012: 22015: 12017: 12018: 12019: 72022: 12026 (partial year): 1, 1 Class I
2007high 19 (2010) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · LJT

4,308in 2025

2007: 2082008: 1612009: 1722010: 2072011: 2022012: 1532013: 1412014: 1432015: 1492016: 1352017: 2622018: 8782019: 7652020: 9592021: 1,2852022: 1,3342023: 1,2212024: 1,8962025: 4,308
2007high 4,308 (2025) · low 135 (2016)2025

MAUDE reports naming product code LJT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711851208
200871192161
20092—2172
20102—19207
201151441202
20122—2153
201371500141
20142—0143
201541641149
201631820135
20170—1262
20180—1878
20191—7765
20201—0959
20210—01,285
20220—11,334
20231—01,221
20241—01,896
20252—04,308
20261—1 (1)—

What is it indicated for?

THE POWER INJECTABLE IMPLANTABLE INFUSION PORT IS INDICATED FOR PATIENT THERAPIES REQUIRING REPEATED ACCESS TO THE VASCULAR SYSTEM. THE PORT SYSTEM CAN BE USED FOR INFUSION OF MEDICATIONS, LV. FLUIDS, PARENTERAL NUTRITION SOLUTIONS, BLOOD PRODUCTS AND FOR THE WITHDRAWAL OF BLOOD SAMPLES.

WHEN USED WITH A POWER INJECTABLE NEEDLE, THE POWER INJECTABLE INFUSION PORT IS INDICATED FOR POWER INJECTION OF CONTRAST MEDIA. FOR POWER INJECTION OF CONTRAST MEDIA, THE MAXIMUM RECOMMENDED INFUSION RATE IS 5 ML/S WITH A 19 OR 20 GAUGE NON-CORING POWER INJECTABLE NEEDLE.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K070003: Power Injectable Implantable Infusion Port with Silicone Lumen (Attachable and Pre-Attached).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K070003

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026