510(k) · Cleared
ClearedAuto Detect for Telaheart DR200/E-a
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
North East Monitoring, Inc. · MWJ Electrocardiograph, Ambulatory (Without Analysis)
Cleared on May 25, 2007 as substantially equivalent to K061293 (North East Monitoring, Inc., 2006) and 1 other predicate after a 142-day review. Its family tree reaches back 4 generations to 1992.
- Decided
- May 25, 2007
- Review
- 142 days
- Class
- Class II
- Product code
- MWJ
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K923930 (1992). 10 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK923930 Electrocardiograph TransmitterTz Medical, Inc. · 1992
- 3 generations backK981394 Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720Braemar Corp. · 1998
- 2 generations backK030856 ER800 Series Ecg Event RecorderBraemar Corp. · 2003
- 1 generation backK061293 Telaheart Digital RecorderNorth East Monitoring, Inc. · 2006
- This deviceK070014 Auto Detect for Telaheart DR200/E-aNorth East Monitoring, Inc. · 2007
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K923930 | Electrocardiograph Transmitter | Tz Medical, Inc. | 1992 | — |
| −3 | K981394 | Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720 | Braemar Corp. | 1998 | — |
| −2 | K030856 | ER800 Series Ecg Event Recorder | Braemar Corp. | 2003 | — |
| −1 | K061293 | Telaheart Digital Recorder | North East Monitoring, Inc. | 2006 | — |
| 0 (this device) | K070014 | Auto Detect for Telaheart DR200/E-a | North East Monitoring, Inc. | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 2 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
| 2004 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MWJ device
- #1 K254119 Wearable ECG Recorder (YMHeart XY-12)…score 14.1 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K061293 | Telaheart Digital RecorderSummary page 2…assification: Class II, 21 CFR 870.2800, MWJ Class Ii, 21 CFR 870.2920, DXH Predicate Device [21 CFR 807.92(a)(3)] * NorthEast Monitoring Telaheart - K061293 * Heartrak Smart AT - K033451 Auto Detect feature compared to Telaheart The subject device (DR200/HE-a and T… | 2006 |
| * | K033451 | Heartrak Smart at/Heartrak SMART2Summary page 2…00, MWJ Class Ii, 21 CFR 870.2920, DXH Predicate Device [21 CFR 807.92(a)(3)] * NorthEast Monitoring Telaheart - K061293 * Heartrak Smart AT - K033451 Auto Detect feature compared to Telaheart The subject device (DR200/HE-a and Telaheart DR200/E-a) is identical to the p… | 2004 |
| † | K930564 | Holter for Windows | 1995 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 4.5 years on median.
- None of the 10 ancestors has a recall.
- 1 other device also cites its predicate K061293.
How does its category compare?
All MWJ devicesMWJ Electrocardiograph, Ambulatory (Without Analysis): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · MWJ
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · MWJ
337in 2022
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MWJ
2in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MWJ
8in 2025
MAUDE reports naming product code MWJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 142 | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 2 | — | 0 | 5 |
| 2010 | 3 | 90 | 0 | 0 |
| 2011 | 3 | 206 | 0 | 0 |
| 2012 | 1 | — | 0 | 2 |
| 2013 | 3 | 241 | 0 | 4 |
| 2014 | 2 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 2 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 1 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 4 |
| 2020 | 0 | — | 0 | 12 |
| 2021 | 1 | — | 0 | 3 |
| 2022 | 4 | 337 | 0 | 6 |
| 2023 | 0 | — | 0 | 5 |
| 2024 | 2 | — | 2 | 3 |
| 2025 | 0 | — | 0 | 8 |
| 2026 | 5 | 270 | 0 | — |
What is it indicated for?
The Telaheart Digital Recorder can be used in Holter mode and Event Recorder mode. Holter Mode Detection of Arrhythmias, Efficacy of Pharmacological Treatment, and Pacemaker Evaluation. Event Recorder The Telaheart event recorder module is a patient activated device designed to record and for diagnostic evaluation of transient symptoms (such as dizziness, palpitations, syncope, and chest pain). Once data is recorded, the data is transmitted via telephone…
Read the full statement (108 words)
The Telaheart Digital Recorder can be used in Holter mode and Event Recorder mode.
Holter Mode
Detection of Arrhythmias, Efficacy of Pharmacological Treatment, and Pacemaker Evaluation.
Event Recorder
The Telaheart event recorder module is a patient activated device designed to record and for diagnostic evaluation of transient symptoms (such as dizziness, palpitations, syncope, and chest pain). Once data is recorded, the data is transmitted via telephone for evaluation.
The device includes the Auto Detect feature which can be used as a looping event recorder to capture events automatically or when activated by the patient. When one or more events are captured the patient may transmit his/her recordings transtelephonically.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070014 · printed Nov 5, 2026
Cite this page
510(k) Report. “K070014: Auto Detect for Telaheart DR200/E-a.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K070014
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026