510(k) Report

510(k) · Cleared

Cleared

Tripore, Models HA, BP90, BP15

K070132510(k) TraditionalCleared Jul 13, 2007178-day reviewClass II21 CFR 888.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Orthogem Limited · MQV Filler, Bone Void, Calcium Compound

Cleared on Jul 13, 2007 after a 178-day review. The FDA summary names its predicate without a number. 3 later devices descend from it.

Decided
Jul 13, 2007
Review
178 days
Class
Class II
Product code
MQV
Recalls
None
Predicates
0

3 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2021: 1 descendant cleared2015: 1 descendant cleared20052010201520202025
  1. This deviceK070132 Tripore, Models HA, BP90, BP15Orthogem Limited · 2007
  2. Descendant · cites it directly · 1 of its ownK110787 Tripore TDD (HA), Tripore TDD (BP90), Tripore TDD (BP15)Orthogem Limited · 2011
  3. Descendant · cites it directly · 0 of its ownK202639 si-MochiBiostone, Ltd. · 2021
  4. Descendant · cites it directly · 0 of its ownK150064 Synthetic Bone Graft (TriPore HA, TriPore BP90, TriPore BP15)Orthogem, Ltd. · 2015

Most influential descendants

Showing 3 of 3 · See all
  • K110787Tripore TDD (HA), Tripore TDD (BP90), Tripore TDD (BP15)Orthogem Limited · 2011 · cites it directly1descendant
  • K202639si-MochiBiostone, Ltd. · 2021 · cites it directly0descendants
  • K150064Synthetic Bone Graft (TriPore HA, TriPore BP90, TriPore BP15)Orthogem, Ltd. · 2015 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K070132Tripore, Models HA, BP90, BP15Orthogem Limited2007—
+1K110787Tripore TDD (HA), Tripore TDD (BP90), Tripore TDD (BP15)Orthogem Limited2011—
+1K202639si-MochiBiostone, Ltd.2021—
+1K150064Synthetic Bone Graft (TriPore HA, TriPore BP90, TriPore BP15)Orthogem, Ltd.2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201510
202110
FIG. 1 — Lineage of K070132, 2007–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQV device

  1. #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Orthovita Vitoss
Named without a submission number
—

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110787Tripore TDD (HA), Tripore TDD (BP90), Tripore TDD (BP15)Orthogem Limited20111
K202639si-MochiBiostone, Ltd.20210
K150064Synthetic Bone Graft (TriPore HA, TriPore BP90, TriPore BP15)Orthogem, Ltd.20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K110787 (Orthogem Limited, 2011) has gone furthest, with 1 descendant of its own.

How does its category compare?

All MQV devices

MQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MQV

14in 2025

2007: 352008: 322009: 232010: 172011: 162012: 92013: 122014: 202015: 182016: 82017: 172018: 232019: 132020: 152021: 82022: 92023: 212024: 282025: 142026 (partial year): 5
2007high 35 (2007) · low 8 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQV

57in 2025

2007: 144 days median2008: 102 days median2009: 180 days median2010: 147 days median2011: 92 days median2012: 107 days median2013: 197 days median2014: 153 days median2015: 184 days median2016: 214 days median2017: 124 days median2018: 124 days median2019: 90 days median2020: 132 days median2021: 88 days median2022: 118 days median2023: 74 days median2024: 55 days median2025: 57 days median2026 (partial year): 96 days median
2007high 214 (2016) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQV

1in 2025

2007: 52008: 32009: 12011: 62012: 32013: 22016: 12017: 12018: 22020: 12023: 32024: 22025: 12026 (partial year): 4
2007high 6 (2011) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQV

57in 2025

2007: 672008: 712009: 812010: 682011: 1142012: 1492013: 2232014: 1112015: 1252016: 1062017: 1072018: 862019: 652020: 1262021: 1012022: 472023: 1202024: 682025: 57
2007high 223 (2013) · low 47 (2022)2025

MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735144567
200832102371
200923180181
201017147068
201116926114
201291073149
2013121972223
2014201530111
2015181840125
201682141106
2017171241107
201823124286
20191390065
2020151321126
20218880101
20229118047
202321743120
20242855268
20251457157
20265964—

What is it indicated for?

TriPore HA, TriPore BP90 and TriPore BP15 is intended to be packed into bone defects of the skeletal system (extremities, spine or pelvis) which are not intrinsic to the stability of the bony structure. These defects may be surgically created voids or from traumatic injury to the bone. This device can also be used for maxillofacial surgery for the reconstruction of the facial skeleton. The device gradually resorbs and is replaced with bone during the healing process. Rigid fixation techniques should be used in conjunction with this device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K070132: Tripore, Models HA, BP90, BP15.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070132

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026