Ultrapro Plug

K070224510(k) TraditionalCleared Apr 17, 200783-day reviewClass II21 CFR 878.3300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ETHICON, Inc. · FTL Mesh, Surgical, Polymeric

Cleared on Apr 17, 2007 as substantially equivalent to K033337 (ETHICON, Inc., 2004) and 1 other predicate after an 83-day review. Its family tree reaches back 1 generation to 1992. 1 later device descends from it.

Decided
Apr 17, 2007
Review
83 days
Class
Class II
Product code
FTL
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K922916 (1992). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2014: 1 descendant clearedK922916 · Bard Marlex Mesh Dart · C.R. Bard, Inc. · 19921990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K922916 · Bard Marlex Mesh Dart · C.R. Bard, Inc. · 19920
  1. Root · 1 generation backK922916 Bard Marlex Mesh DartC.R. Bard, Inc. · 1992
  2. This deviceK070224 Ultrapro PlugETHICON, Inc. · 2007
  3. Descendant · cites it directly · 0 of its ownK133198 Ultrapro Comfort PlugETHICON, Inc. · 2014

Most influential descendants

Showing 1 of 1 · See all
  • K133198Ultrapro Comfort PlugETHICON, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K922916Bard Marlex Mesh DartC.R. Bard, Inc.1992—
0 (this device)K070224Ultrapro PlugETHICON, Inc.2007—
+1K133198Ultrapro Comfort PlugETHICON, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
FIG. 1 — Lineage of K070224, 1992–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FTL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FTL device

  1. #1 K220091 Poly-Tape/Infinity-Lock Soft Tissue…score 16.8 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033337Ultrapro Mesh
Summary page 1
…f Device: Class II in 21 CFR § 878.3300, Surgical Mesh (FTL) Trade Name: ULTRAPRO* Plug Predicate Devices: ULTRAPRO* Mesh (ETHICON, Inc.) - K033337 BARD Mesh PerFix Plug (Davol, Inc.) - K922916 Statement of Intended Use: ULTRAPRO Plug is a partially absorb…
ETHICON, Inc.2004—
*K922916Bard Marlex Mesh Dart
Summary page 1
…al Mesh (FTL) Trade Name: ULTRAPRO* Plug Predicate Devices: ULTRAPRO* Mesh (ETHICON, Inc.) - K033337 BARD Mesh PerFix Plug (Davol, Inc.) - K922916 Statement of Intended Use: ULTRAPRO Plug is a partially absorbable device used to fill and reinforce inguina…
C.R. Bard, Inc.1992—

Also cleared against K033337: 8 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133198Ultrapro Comfort PlugETHICON, Inc.20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K133198 (ETHICON, Inc., 2014) has gone furthest, with 0 descendants of its own.
  • 8 other devices also cite its predicate K033337.

How does its category compare?

All FTL devices

FTL Mesh, Surgical, Polymeric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · FTL

6in 2025

2007: 202008: 232009: 152010: 182011: 152012: 122013: 82014: 112015: 122016: 32017: 62018: 122019: 42020: 52021: 22022: 62023: 42024: 22025: 62026 (partial year): 2
2007high 23 (2008) · low 2 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FTL

30in 2025

2007: 92 days median2008: 114 days median2009: 97 days median2010: 132 days median2011: 90 days median2012: 213 days median2013: 90 days median2014: 70 days median2015: 121 days median2016: 186 days median2017: 132 days median2018: 105 days median2019: 99 days median2020: 138 days median2022: 195 days median2023: 29 days median2025: 30 days median
2007high 213 (2012) · low 29 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FTL

1in 2020

2007: 22008: 12009: 12010: 122011: 82012: 22013: 12014: 32017: 12018: 12020: 1
2007high 12 (2010) · low 0 (2015)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FTL

3,487in 2025

2007: 1,7372008: 1,5692009: 1,9062010: 2,1752011: 3,6082012: 14,7002013: 26,5192014: 2,6832015: 2,5262016: 2,4172017: 3,9472018: 11,8932019: 21,7242020: 18,8192021: 16,2842022: 11,4392023: 8,0252024: 8,5652025: 3,487
2007high 26,519 (2013) · low 1,569 (2008)2025

MAUDE reports naming product code FTL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007209221,737
20082311411,569
2009159711,906
201018132122,175
2011159083,608
201212213214,700
2013890126,519
2014117032,683
20151212102,526
2016318602,417
2017613213,947
201812105111,893
2019499021,724
20205138118,819
20212—016,284
20226195011,439
202342908,025
20242—08,565
202563003,487
20262—0—

What is it indicated for?

ULTRAPRO Plug is indicated for open repair of groin hernia defects.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K070224: Ultrapro Plug.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070224

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026