510(k) · Cleared
ClearedAdvacoat Sinus Gel and Stent
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Carbylan Biosurgery · LYA Splint, Intranasal Septal
Cleared on Mar 15, 2007 as substantially equivalent to K063308 (Carbylan Biosurgery, 2006) and 3 other predicates after a 23-day review. Its family tree reaches back 3 generations to 1997. 3 later devices descend from it.
- Decided
- Mar 15, 2007
- Review
- 23 days
- Class
- Class I
- Product code
- LYA
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 3 generations to K972082 (1997). 6 ancestors in all. 3 later devices descend from it, 2 citing it directly.
- Root · 3 generations backK972082 Custom Nasal SplintBoston Medical Products, Inc. · 1997
- 2 generations backK012532 Sepragel SinusGenzyme Corp. · 2001
- 1 generation backK063308 Advacoat Sinus Gel, Model 9100, Adva Sinus Stent, Model 9200Carbylan Biosurgery · 2006
- This deviceK070496 Advacoat Sinus Gel and StentCarbylan Biosurgery · 2007
- Descendant · cites it directly · 1 of its ownK092401 Sinexus Sinus Stent Gen 2, Model 1999-25Sinexus, Inc. · 2009
- Descendant · 2 generations on · 0 of its ownK170913 Composite Removable Sinus Stent SystemSts Medical · 2017
- Descendant · cites it directly · 0 of its ownK160101 SinuBandBioinspire Technologies, Incorporated · 2016
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K972082 | Custom Nasal Splint | Boston Medical Products, Inc. | 1997 | — |
| −2 | K012532 | Sepragel Sinus | Genzyme Corp. | 2001 | — |
| −1 | K063308 | Advacoat Sinus Gel, Model 9100, Adva Sinus Stent, Model 9200 | Carbylan Biosurgery | 2006 | — |
| 0 (this device) | K070496 | Advacoat Sinus Gel and Stent | Carbylan Biosurgery | 2007 | — |
| +1 | K092401 | Sinexus Sinus Stent Gen 2, Model 1999-25 | Sinexus, Inc. | 2009 | — |
| +2 | K170913 | Composite Removable Sinus Stent System | Sts Medical | 2017 | — |
| +1 | K160101 | SinuBand | Bioinspire Technologies, Incorporated | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
| 2001 | 1 | 0 |
| 2004 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2009 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LYA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LYA device
- #1 K243655 TurbAlignscore 10.0 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K063308 | Advacoat Sinus Gel, Model 9100, Adva Sinus Stent, Model 9200Summary page 1…R 874.4780 Product Code Number: LYA Performance Standards: No FDA performance standards exist for this product. Predicate Devices: AdvaCoat Sinus Gel and Stent (K063308) Hyalsine Hylan B Gel (K012532) MeroPack (K041 381) Merogel Nasal Dressing And Sinus Stent (K982731) Device Description:… | 2006 |
| * | K012532 | Sepragel SinusSummary page 1…LYA Performance Standards: No FDA performance standards exist for this product. Predicate Devices: AdvaCoat Sinus Gel and Stent (K063308) Hyalsine Hylan B Gel (K012532) MeroPack (K041 381) Merogel Nasal Dressing And Sinus Stent (K982731) Device Description: AdvaCoatTM Sinus Gel and Stent… | 2001 |
| * | K041381 | Meropack Bioresorbable Nasal Packing and Sinus StentSummary page 1…ards: No FDA performance standards exist for this product. Predicate Devices: AdvaCoat Sinus Gel and Stent (K063308) Hyalsine Hylan B Gel (K012532) MeroPack (K041 381) Merogel Nasal Dressing And Sinus Stent (K982731) Device Description: AdvaCoatTM Sinus Gel and Stent (AdvaCoat'~') is a ster… | 2004 |
| * | K982731 | Merogel Nasal Dressing and Sinus StentSummary page 1…product. Predicate Devices: AdvaCoat Sinus Gel and Stent (K063308) Hyalsine Hylan B Gel (K012532) MeroPack (K041 381) Merogel Nasal Dressing And Sinus Stent (K982731) Device Description: AdvaCoatTM Sinus Gel and Stent (AdvaCoat'~') is a sterile, non-pyrogenic, viscoelastic, bioresorbable ma… | 1999 |
What descends from it? (3)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 4.3 years on median.
- None of the 6 ancestors has a recall.
- Of its descendants, K092401 (Sinexus, Inc., 2009) has gone furthest, with 1 descendant of its own.
How does its category compare?
All LYA devicesLYA Splint, Intranasal Septal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · LYA
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LYA
104in 2014
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LYA
No recall names LYA since 2007.
Adverse event reports per year · LYA
1in 2025
MAUDE reports naming product code LYA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 2 |
| 2008 | 2 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 5 |
| 2010 | 0 | — | 0 | 2 |
| 2011 | 0 | — | 0 | 16 |
| 2012 | 1 | — | 0 | 16 |
| 2013 | 2 | — | 0 | 1 |
| 2014 | 5 | 104 | 0 | 4 |
| 2015 | 0 | — | 0 | 28 |
| 2016 | 1 | — | 0 | 28 |
| 2017 | 2 | — | 0 | 10 |
| 2018 | 2 | — | 0 | 19 |
| 2019 | 0 | — | 0 | 5 |
| 2020 | 1 | — | 0 | 6 |
| 2021 | 1 | — | 0 | 19 |
| 2022 | 0 | — | 0 | 8 |
| 2023 | 1 | — | 0 | 17 |
| 2024 | 0 | — | 0 | 7 |
| 2025 | 1 | — | 0 | 1 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
AdvaCoatTM Sinus Gel is intended for use in patients undergoing nasal/sinus surgery as a space-occupying dressing and/or stent intended to prevent adhesions in the nasal cavity, separate mucosal surfaces compromised by surgery or trauma, minimize edema and help control minimal bleeding following surgery or trauma, and act as an adjunct to aid in the natural healing process.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070496 · printed Nov 6, 2026
Cite this page
510(k) Report. “K070496: Advacoat Sinus Gel and Stent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070496
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026