510(k) Report

510(k) · Cleared

Cleared

Orthoblast II DBM Demineralized Bone Matrix Paste and Putty

K070751510(k) TraditionalCleared Oct 15, 2007210-day reviewClass II21 CFR 888.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Isotis Orthobiologics, Inc. · MQV Filler, Bone Void, Calcium Compound

Cleared on Oct 15, 2007 as substantially equivalent to K040419 (Isotis Orthobiologics, Inc., 2005) and 1 other predicate after a 210-day review. Its family tree reaches back 3 generations to 2004. 1 later device descends from it.

Decided
Oct 15, 2007
Review
210 days
Class
Class II
Product code
MQV
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K040980 (2004). 4 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK040980 Allomatrix C Putty, Allomatrix Custom Putty, Allomatrix DR Putty…Wrightmedicaltechnologyinc · 2004
  2. 2 generations backK040419 Dynagraft IIIsotis Orthobiologics, Inc. · 2005
  3. 1 generation backK050642 Orthoblast II Putty and PasteIsotis Orthobiologics, Inc. · 2005
  4. This deviceK070751 Orthoblast II DBM Demineralized Bone Matrix Paste and PuttyIsotis Orthobiologics, Inc. · 2007
  5. Descendant · cites it directly · 0 of its ownK103036 Allofuse PlusAllosource, Inc. · 2011

Most influential descendants

Showing 1 of 1 · See all
  • K103036Allofuse PlusAllosource, Inc. · 2011 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K040980Allomatrix C Putty, Allomatrix Custom Putty, Allomatrix DR Putty, Ignite…Wrightmedicaltechnologyinc2004—
−2K040419Dynagraft IIIsotis Orthobiologics, Inc.2005—
−1K050642Orthoblast II Putty and PasteIsotis Orthobiologics, Inc.2005—
0 (this device)K070751Orthoblast II DBM Demineralized Bone Matrix Paste and PuttyIsotis Orthobiologics, Inc.2007—
+1K103036Allofuse PlusAllosource, Inc.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
FIG. 1 — Lineage of K070751, 2004–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQV device

  1. #1 K232315 Catalyst Bone Void Fillerscore 25.2 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040419Dynagraft II
Summary page 1
…Regulatory Class: 1i Product Code: MQV 5.3. PREDICATE DEVICE DynaGraft 1I(Demineralized Bone Matrix): K040419 OrthoBlast 11Paste and Putty K050642 5.4. DEVICE DESCRIPTION Ortho…
Isotis Orthobiologics, Inc.2005—
*K050642Orthoblast II Putty and Paste
Summary page 1
…5.3. PREDICATE DEVICE DynaGraft 1I(Demineralized Bone Matrix): K040419 OrthoBlast 11Paste and Putty K050642 5.4. DEVICE DESCRIPTION OrthoBlast®II DBM Putty and Paste is derived from selected donated…
Isotis Orthobiologics, Inc.2005—

Also cleared against K040419: 7 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K103036Allofuse PlusAllosource, Inc.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 8 months on median.
  • 1 of the 4 ancestors has a recall of any class.
  • Of its descendants, K103036 (Allosource, Inc., 2011) has gone furthest, with 0 descendants of its own.
  • 7 other devices also cite its predicate K040419.

How does its category compare?

All MQV devices

MQV Filler, Bone Void, Calcium Compound: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MQV

14in 2025

2007: 352008: 322009: 232010: 172011: 162012: 92013: 122014: 202015: 182016: 82017: 172018: 232019: 132020: 152021: 82022: 92023: 212024: 282025: 142026 (partial year): 5
2007high 35 (2007) · low 8 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQV

57in 2025

2007: 144 days median2008: 102 days median2009: 180 days median2010: 147 days median2011: 92 days median2012: 107 days median2013: 197 days median2014: 153 days median2015: 184 days median2016: 214 days median2017: 124 days median2018: 124 days median2019: 90 days median2020: 132 days median2021: 88 days median2022: 118 days median2023: 74 days median2024: 55 days median2025: 57 days median2026 (partial year): 96 days median
2007high 214 (2016) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQV

1in 2025

2007: 52008: 32009: 12011: 62012: 32013: 22016: 12017: 12018: 22020: 12023: 32024: 22025: 12026 (partial year): 4
2007high 6 (2011) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQV

57in 2025

2007: 672008: 712009: 812010: 682011: 1142012: 1492013: 2232014: 1112015: 1252016: 1062017: 1072018: 862019: 652020: 1262021: 1012022: 472023: 1202024: 682025: 57
2007high 223 (2013) · low 47 (2022)2025

MAUDE reports naming product code MQV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735144567
200832102371
200923180181
201017147068
201116926114
201291073149
2013121972223
2014201530111
2015181840125
201682141106
2017171241107
201823124286
20191390065
2020151321126
20218880101
20229118047
202321743120
20242855268
20251457157
20265964—

What is it indicated for?

For orthopedic use, the OrthoBlast It Paste and Putty are intended for use as an autograft extender (extremities, spine and pelvis) and as a bone void filler (extremities and pelvis) for bony voids or gaps that are not intrinsic to the stability of the bony structure. The OrthoBlast IIproducts are indicated to be packed gently into bony defects of the skeletal system. These defects may be surgically created or from the result of traumatic injury to the bone

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K070751: Orthoblast II DBM Demineralized Bone Matrix Paste and Putty.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K070751

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026